Abstract
It has been demonstrated that the performance of typical unimodal brain-computer interfaces (BCIs) can be noticeably improved by combining two different BCI modalities. This so-called "hybrid BCI" technology has been studied for decades; however, hybrid BCIs that particularly combine electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) (hereafter referred to as hBCIs) have not been widely used in practical settings. One of the main reasons why hBCI systems are so unpopular is that their hardware is generally too bulky and complex. Therefore, to make hBCIs more appealing, it is necessary to implement a lightweight and compact hBCI system with minimal performance degradation. In this study, we investigated the feasibility of implementing a compact hBCI system with significantly less EEG channels and fNIRS source-detector (SD) pairs, but that can achieve a classification accuracy high enough to be used in practical BCI applications. EEG and fNIRS data were acquired while participants performed three different mental tasks consisting of mental arithmetic, right-hand motor imagery, and an idle state. Our analysis results showed that the three mental states could be classified with a fairly high classification accuracy of 77.6 ± 12.1% using an hBCI system with only two EEG channels and two fNIRS SD pairs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig 1 Arrangement of EEG channels (blue) and fNIRS optodes (red: Sources, green: Detectors) on the frontal (left) and motor (right) areas. Channels were numbered in the same manner as in a previous study [20].](https://figures.cochat.ai/paper-figures/81515620525741e0996158567bd74420/toward-a-compact-hybrid-brain-computer-interface-bci-performance-evaluation-of-figure-1.jpg)




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Separately, the feasibility of non-invasive methods for communication brain computer interfaces is being actively investigated77–80, with the goal of improving signal-to-noise and spatial resolution.”
From The speech neuroprosthesis (2024) · cites this paper as [78]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“com/bbci/bbci_public) were employed [22, 23].”
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
A well-conditioned estimator for large-dimensional covariance matrices
Ledoit, O., & Wolf, M. (2004) · Journal of Multivariate Analysis · doi:10.1016/s0047-259x(03)00096-4 · Cited by 3,046 · cited 1×
“The fNIRS data were segmented into epochs from −1 to 15 s considering that the hemodynamic delay is in the order of several seconds [27].”
MethodBrain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Mu rhythm (de)synchronization and EEG single-trial classification of different motor imagery tasks
Pfurtscheller, G., Brunner, C., Schlögl, A., & Lopes da Silva, F. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.003 · Cited by 1,587
Schäfer, J., & Strimmer, K. (2005) · Statistical Applications in Genetics and Molecular Biology · doi:10.2202/1544-6115.1175 · Cited by 1,561
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Research works printed but not linked: 1
- Tomczak M, Tomczak E. The need to report effect size estimates revisited. An overview of some recommended measures of effect size. Trends Sport Sci. 2014; 21(1).
Cited by
Concurrent fNIRS and EEG for Brain Function Investigation: A Systematic, Methodology-Focused Review
Li, R., Yang, D., Fang, F., Hong, K.-S., Reiss, A. L., & Zhang, Y. (2022) · Sensors · doi:10.3390/s22155865 · Cited by 236
A systematic review on hybrid EEG/fNIRS in brain-computer interface
Liu, Z., Shore, J., Wang, M., Yuan, F., Buss, A. T., & Zhao, X. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102595 · Cited by 167
Silva, A. B., Littlejohn, K. T., Liu, J. R., Moses, D. A., & Chang, E. F. (2024) · Nature Reviews Neuroscience · doi:10.1038/s41583-024-00819-9 · Cited by 103
Analysis of Human Gait Using Hybrid EEG-fNIRS-Based BCI System: A Review
Khan, H., Naseer, N., Yazidi, A., Eide, P. K., Hassan, H. W., & Mirtaheri, P. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.613254 · Cited by 106
Yang, D., Shin, Y., & Hong, K. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.629323 · Cited by 94
“In addition, hybrid neuroimaging modalities have been suggested to evaluate the neuromodulation effect to seek reliable results (Kwon et al., 2020; Lee S. et al., 2020).”
BackgroundEEG-fNIRS-based hybrid image construction and classification using CNN-LSTM
Mughal, N. E., Khan, M. J., Khalil, K., Javed, K., Sajid, H., Naseer, N., Ghafoor, U., & Hong, K. (2022) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2022.873239 · Cited by 63
A Bimodal Deep Learning Architecture for EEG-fNIRS Decoding of Overt and Imagined Speech
Cooney, C., Folli, R., & Coyle, D. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3132861 · Cited by 70
Ali, M. U., Zafar, A., Kallu, K. D., Masood, H., Mannan, M. M. N., Ibrahim, M. M., Kim, S., & Khan, M. A. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3294586 · Cited by 66
“Similarly, researchers have developed a hybrid EEG-fNIRS BCI for classification of three tasks—MA, LHMI, and resting state—using only information from two fNIRS and EEG optodes and channels, respectively [32].”
BackgroundMrachacz‐Kersting, N., Ibáñez, J., & Farina, D. (2021) · The Journal of Physiology · doi:10.1113/jp281314 · Cited by 50
“Recent lines of research have given particular emphasis to multimodal brain-machine interfaces combining different recording and stimulation modalities within the same platform (Gallego et al. 2012; Chiarelli et al. 2018; Corsi et al. 2018; Loopez-Larraz et al. 2018; Khalaf et al. 2019; Asín-Prieto et al. 2020; Kwon e…”
BackgroundQiu, L., Zhong, Y., He, Z., & Pan, J. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.973959 · Cited by 64
“For example, Kwon et al. (2020) investigated the feasibility of implementing a compact hBCI system and found that three mental states (mental arithmetic, right-handed motor image, and idle state) could be classified with a classification accuracy of 77.6± 12.1% using an hybrid BCI system with only…”
MethodInfluentialKwon, J., & Im, C. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.646915 · Cited by 55
“Because Kwon et al. (2020b) recently demonstrated the feasibility of implementing a subject-independent EEG-based BCI using CNN, it is expected that a subject-independent hybrid fNIRS-EEG BCI could also be implemented by incorporating our proposed CNN model for fNIRS-based BCI with Kwon et al.’s…”
BackgroundMethodInfluentialSelf-citationMotor Imagery Decoding Enhancement Based on Hybrid EEG-fNIRS Signals
Xu, T., Zhou, Z., Yang, Y., Li, Y., Li, J., Bezerianos, A., & Wang, H. (2023) · IEEE Access · doi:10.1109/access.2023.3289709 · Cited by 53
Wang, H., Yuan, Z., Zhang, H., Wan, F., Li, Y., & Xu, T. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.107570 · Cited by 40
Salankar, N., Koundal, D., & Qaisar, S. M. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/2146369 · Cited by 41
Browarska, N., Kawala‐Sterniuk, A., Zygarlicki, J., Podpora, M., Pelc, M., Martínek, R., & Gorzelańczyk, E. J. (2021) · Brain Sciences · doi:10.3390/brainsci11010098 · Cited by 41
“Moreover, using less channels enables to make the BCI systems more compact [38].”
MethodZhang, M., Zhu, F., Jia, F., Wu, Y., Wang, B., Gao, L., Chu, F., & Tang, W. (2023) · Neurorehabilitation · doi:10.3233/nre-230215 · Cited by 42
“By building a mixed-mode (Kwon et al., 2020; Colamarino et al., 2021; Hu et al., 2021), user-friendly EEG system (Kam et al., 2019; Cavallo et al., 2021), Colamarino et al. (Colamarino et al., 2022) proposed a novel GUIDER algorithm to make the BCI system more suitable for use by rehabilitation…”
AlQahtani, N. J., Al-Naib, I. A. I., & Althobaiti, M. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1454262 · Cited by 38
Shin, J. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00236 · Cited by 31
“Instead, hybrid EEG-fNIRS BCI, which recently proved excellent in BCI performance, plays a leading role in taking advantage of the benefits of ensemble learning for fNIRS-BCIs (Fazli et al., 2012; Shin et al., 2017b, 2018a,c,d, 2019; Von Lühmann et al., 2017; Kwon et al., 2020).”
BackgroundSelf-citationGao, Y., Liu, H., Fang, F. Z., & Zhang, Y. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3204718 · Cited by 31
“First, single-modality fMRI can only detect the cerebral hemodynamics of the brain but not the neuronal activity, lacking information of the neurovascular coupling process to accurately describe the features of brain activity [9], [10], [11].”
BackgroundHirshfield, L., Wickens, C. D., Doherty, E. J., Spencer, C. A., Williams, T., & Hayne, L. (2023) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2023.2266242 · Cited by 35
“Unfortunately, EEG has poor signal to noise ratio and spatial resolution (Duan et al., 2021; Kwon et al., 2020; Putze et al., 2014).”
Wang, Z., Lu, Y., Zhou, Y., Chen, L., Gu, B., Liu, S., Xu, M., He, F., & Ming, D. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3281855 · Cited by 31
“obtained higher accuracy than previous studies [53], which might be due to different data structures and classification strategies.”
ResultGlobal research on artificial intelligence-enhanced human electroencephalogram analysis
Chen, X., Tao, X., Wang, F. L., & Xie, H. (2021) · Neural Computing and Applications · doi:10.1007/s00521-020-05588-x · Cited by 28
Qing, K., Huang, R., & Hong, K. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.597864 · Cited by 27
“BCIs are also typically used to decode the neural activity of the cerebral to restore motion function or to control machines and robots (Zander and Kothe, 2011; LaFleur et al., 2013; Degrave et al., 2019; Fiederer et al., 2019; Hu et al., 2019; Li and Shi, 2019; Furlan et al., 2020; Grossberg, 2020; Kwon et al., 2020).”
BackgroundCodina, T., Blankertz, B., & von Lühmann, A. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.974 · Cited by 30
Hybrid Integrated Wearable Patch for Brain EEG-fNIRS Monitoring
Li, B., Li, M., Xia, J., Jin, H., Dong, S., & Luo, J. (2024) · Sensors · doi:10.3390/s24154847 · Cited by 18
“In the field of brain–computer interfaces (BCIs) [7,8], the EEG-fNIRS system has been utilized to fabricate a hybrid BCI (hBCI) to improve classification accuracy [9,10].”
MethodGamboa, P., Varandas, R. S. P., Rodrigues, J., Cepeda, C., Quaresma, C., & Gamboa, H. F. S. (2022) · Computers · doi:10.3390/computers11040049 · Cited by 17
“, [15,16]) due to their ecological validity when compared to other techniques, e.”
BackgroundPinto-Orellana, M. A., Khan, H., Ombao, H., & Mirtaheri, P. (2024) · Data Science in Science · doi:10.1080/26941899.2024.2426785 · Cited by 17
A hybrid CNN model for classification of motor tasks obtained from hybrid BCI system
Shelishiyah, R., Thiyam, D. B., Margaret, M. J., & Banu, N. M. M. (2025) · Scientific Reports · doi:10.1038/s41598-024-84883-2 · Cited by 13
OptEF-BCI: An Optimization-Based Hybrid EEG and fNIRS–Brain Computer Interface
Ali, M. U., Kim, K. S., Kallu, K. D., Zafar, A., & Lee, S. W. (2023) · Bioengineering · doi:10.3390/bioengineering10050608 · Cited by 20
“This research group also designed a hybrid BCI model to categorize three activities (MA, RHMI, and resting-state activities) by combining features extracted from two EEG channels and two fNIRS optodes [28].”
MethodGroß, M., & Hennig, B. (2023) · Springer eBooks · doi:10.1007/978-3-662-64118-7_29 · Cited by 11
Shi, X., Wang, H., Li, B., Qin, Y., Peng, C., & Lu, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3538086 · Cited by 27
“Kwon et al. [35] studied the feasibility of implementing a compact hybrid BCI system, using only two EEG channels and two fNIRS source-detector pairs to classify MA, right-hand MI, and resting state.”
Shemyakina, N. V., & Nagornova, Z. V. (2020) · Human Physiology · doi:10.1134/s0362119720060092 · Cited by 10
A Novel Cognition-Guided Neurofeedback BCI Dataset on Nicotine Addiction
Bu, J., Liu, C., Gou, H., Gan, H., Cheng, Y. F., Liu, M., Ni, R., Liang, Z., Cui, G., Zeng, G. Q., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.647844 · Cited by 10
“Among them, EEG is the most widely used BCIs (Kwon et al., 2020).”
BackgroundHemodynamic Response Detection Using Integrated EEG-fNIRS-VPA for BCI
Arif, A., Khan, M. J., Javed, K., Sajid, H., Rubab, S., Naseer, N., & Khan, T. I. (2021) · Computers, materials & continua/Computers, materials & continua (Print) · doi:10.32604/cmc.2022.018318 · Cited by 11
Wearable Pair of EEG, EOG and fNIRS Glasses for Cognitive Workload Detection
Kosmyna, N., Adl, K. E., & Kim, M. M. (2024) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn63547.2024.10780518 · Cited by 7
Brain-computer interface technology for motor rehabilitation in severe stroke: a narrative review
Li, Y., Yi, R., & Hu, Z. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1822784 · Cited by 5
“EEG offers great temporal resolution, is portable, and has a low cost (Abiri et al., 2019; Kwon et al., 2020).”
InfluentialRogers, D., O’Brien, W. J., Gao, Y., Zimmermann, B. B., Grover, S., Zhang, Y., Gaona, A. K., Duwadi, S., Anderson, J. E., Carlton, L. B., et al. (2025) · Neurophotonics · doi:10.1117/1.nph.12.2.025006 · Cited by 4
IIMCNet: Intra- and Inter-Modality Correlation Network for Hybrid EEG-fNIRS Brain-Computer Interface
Yuan, X., Zhang, Y., & Rolfe, P. J. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3594203 · Cited by 8
Caulier‐Cisterna, R., Appelgren, J. P. G., Oyarzún, J. E., Valenzuela, F., Sitaram, R., Eblén-Zajjur, A., & Uribe, S. A. (2024) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2024.104170 · Cited by 5
Mwata-Velu, T., Zamora, E., Vasquez-Gomez, J. I., Ruiz-Pinales, J., & Sossa, H. (2024) · Sensors · doi:10.3390/s24123968 · Cited by 6
“On this basis, Kwon et al. [21] implemented a compact hybrid BCI based on EEG and fNIRS using the channel selection and source–detector (SD) pair approaches.”
MethodEssam, A.-A., Ibrahim, A., Al-Nasr, A. S., El-Saqa, M., Mohamed, S., Anwar, A., Eldeib, A., Akçakaya, M., & Khalaf, A. F. (2025) · PLoS ONE · doi:10.1371/journal.pone.0311075 · Cited by 4
“Non-invasive BCIs are safer, offering high accessibility, cost effectiveness, and scalability [9,10].”
The Influence of Frequency Bands and Brain Region on ECoG-Based BMI Learning Performance
Jung, W., Lim, S., Kwak, Y., Sim, J., Park, J., & Jang, D. (2021) · Sensors · doi:10.3390/s21206729 · Cited by 3
A Neurophysiological Sensor Suite for Real-Time Prediction of Pilot Workload in Operational Settings
Grant, T., Dhruv, K., Eloy, L., Hayne, L., Durkee, K. T., & Hirshfield, L. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-60128-7_5 · Cited by 2
The influence of paradigm interface guided by different visual types on MI-BCI performance
Shao, J., Bai, Y., Yao, J. P., Zhang, Y., Tian, F., & Xue, C. (2024) · Behaviour and Information Technology · doi:10.1080/0144929x.2024.2312436 · Cited by 2
“MI-BCI performance can vary greatly among users, about 20% of the users in their study produce MI signals in a mental task that cannot be distinguishable for e ff ective control of external devices (Kwon, Shin, and Im 2020).”
Fairclough, S. H., Dobbins, C., & Stamp, K. (2021) · Frontiers in Neuroergonomics · doi:10.3389/fnrgo.2021.695309 · Cited by 2
“These methods were selected on the basis of their previous applications for fNIRS-based BCI and classification of experimental pain (Naseer and Hong, 2015; Hong et al., 2018; Fernandez Rojas et al., 2019; Kwon et al., 2020).”
MethodOn decoding of rapid motor imagery in a diverse population using a high-density NIRS device
Kothe, C. A., Hanada, G., Mullen, S., & Mullen, T. R. (2024) · Frontiers in Neuroergonomics · doi:10.3389/fnrgo.2024.1355534 · Cited by 2
Thakur, S., Thakur, S., Rana, A., Kumar, P., & Das, A. K. (2026) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2025.2602691 · Cited by 3
Recurrence analysis in the detection of continuous task episodes for asynchronous BCI
Ramírez, C. I. L., Bojorges-Valdez, E., Yáñez-Suárez, Ó., & Piña-Ramírez, O. (2020) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc42975.2020.9282907 · Cited by 1
“[20], have suggested the use of central electrodes in paradigms involving mental arithmetic.”
BackgroundGuo, Z., & Xu, L. (2021) · International Conference on Intelligent Computing and Control Systems (ICICCS) · doi:10.1109/iciccs51141.2021.9432104
“…can then reflect the global structure of the data or data distribution, such as isosurface, volume rendering, and overall visual mapping, then without data down-sampling or interval interception, single-time as the amount of visualization calculations for step data will reach its peak [11, 12].”
BackgroundBrain-Computer Interface Technology in Stroke Rehabilitation
Zhao, C. (2024) · MedScien · doi:10.61173/4y3cdc08
Deep multimodal representation learning for noninvasive neural speech decoding
Cooney, C., Folli, R., & Coyle, D. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95437-2.00012-4 · Cited by 1
Design Elements in Brain-Computer Interface for Working Memory: A Decade Review
Nurlatifah, I., Nayan, N. M., & Ali, N. M. (2025) · Lecture notes in computer science · doi:10.1007/978-981-95-3808-9_6 · Cited by 1
Faisal, M., Sahoo, S., & Hazarika, J. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.7170606
Metadata
- Authors
- Kwon, J., Shin, J., & Im, C.-H.
- Affiliations
- Hanyang University (KR)
- Wonkwang University (KR)
- Corresponding author
- Im, Chang-Hwan
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2020-03-18
- Volume
- 15
- Issue
- 3
- Pages
- e0230491
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC7080269
- OpenAlex
- W3010955800
- Cited by
- 53
- References
- 41
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 11 · 2023: 7 · 2022: 5 · 2021: 15 · 2020: 4
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- National Research Foundation
- National Research Foundation of Korea (2017-0-00432, 2015M3C7A1031969, NRF‐2015M3C7A1031969, 2019M3C7A1031278, NRF-2019M3C7A1031278)
- Ministry of Science and ICT, South Korea (NRF-2019M3C7A1031278, 2017-0-00432)
- Institute for Information and Communications Technology Promotion (2017-0-00432)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Keywords
- hybrid brain-computer interface, functional near-infrared spectroscopy, EEG, multi-class classification, mental arithmetic, motor imagery, mental state classification
- MeSH terms
- Adult, Electroencephalography, Female, Humans, Male, Models, Theoretical, Motor Cortex, Psychomotor Performance, Spectroscopy, Near-Infrared, Young Adult, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.