Background: We compared HbA1c values obtained from capillary blood collection kits versus venous whole blood collections in study participants with type 1 or type 2 diabetes. Methods: A total of 122 subjects, 64 with type 2 diabetes participating in the Glycemia Reduction Approaches in Diabetes: A Comparative Effectiveness (GRADE) Study and 58 with type 1 diabetes from the Epidemiology of Diabetes Interventions and Complications (EDIC) Study, participated in the validation study. Capillary tubes were filled by fingerstick by the participants on the same day as the collection of venous whole blood samples in EDTA-containing test tubes and were mailed to the central laboratory. HbA1c in all samples was measured with the same high-performance liquid chromatography. GRADE participants also completed a questionnaire on the ease of performing capillary collections. Results: Participants from 22 clinical centers (GRADE n = 5, EDIC n = 17) were between 35 and 86 years of age, with 52% male and diverse race/ethnicities. Venous HbA1c results ranged between 5.4–11.9% (35.5–106.6 mmol/mol) with corresponding capillary results ranging between 4.2–11.9% (22.4–106.6 mmol/mol). The venous and capillary results were highly correlated (R 2 = 0.993) and 96.7% differed by ≤0.2% (2.2 mmol/mol). Of participants surveyed, 69% indicated that the instructions and collection were easy to follow and 97% felt the collection method would be easy to do at home. Conclusions: The capillary blood HbA1c results compared well with the conventional venous whole blood results. The capillary kits can be employed in other studies to reduce interruption of critical data collection and potentially to augment clinical care when in-person visits are not possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The accuracy of such collection methods has been validated in several large research cohorts (353,354).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [354]
The cited source says what the claim attributes to it.
In the citing paper
“Capillary blood sample kits have been used in research studies and shown to perform well compared with venous whole-blood samples when assayed with a high-performance chromatography method (353,354).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [354]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Self-citationNathan, D. M., Buse, J. B., Kahn, S. E., Krause-Steinrauf, H., Larkin, M. E., Staten, M., Wexler, D., Lachin, J. M., & the GRADE Study Research Group (2013) · Diabetes Care · doi:10.2337/dc13-0356 · Cited by 254
Self-citationThe role of measurement reliability in clinical trials
Lachin, J. M. (2004) · Clinical Trials · doi:10.1191/1740774504cn057oa · Cited by 234
Self-citationSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9997 · Cited by 170
Self-citationWexler, D. J., Krause-Steinrauf, H., Crandall, J. P., Florez, H. J., Hox, S. H., Kuhn, A., Sood, A., Underkofler, C., Aroda, V. R., GRADE Research Group, et al. (2019) · Diabetes Care · doi:10.2337/dc19-0901 · Cited by 44
Self-citationAn evaluation of two capillary sample collection kits for laboratory measurement of HbA1c
Beck, R. W., Bocchino, L. E., Lum, J. W., Kollman, C., Barnes-Lomen, V., Sulik, M., Haller, M. J., Bode, B., Cernich, J. T., Killeen, A. A., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0023 · Cited by 42
Evaluation of Capillary Collection System for HbA1c Specimens
Voss, E. M., Cembrowski, G. S., Clasen, B. L., Spencer, M. L., Ainslie, M. B., & Haig, B. (1992) · Diabetes Care · doi:10.2337/diacare.15.5.700 · Cited by 28
Stability of Mailed and Couriered Capillary HbA1c Samples
Voss, E. M., Cembrowski, G. S., Haig, B., & Spencer, M. L. (1993) · Diabetes Care · doi:10.2337/diacare.16.4.665 · Cited by 5
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Self-citationGlycemia Reduction in Type 2 Diabetes — Glycemic Outcomes
The GRADE Study Research Group (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2200433 · Cited by 222
Self-citationSacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 205
Self-citationIGUDESMAN, D. A., Crandell, J., Corbin, K. D., Muntis, F. R., Zaharieva, D. P., Casu, A., Thomas, J. M., Bulik, C. M., Carroll, I. M., Pence, B. W., et al. (2022) · Current Developments in Nutrition · doi:10.1093/cdn/nzac107 · Cited by 17
Garvey, W. T., Cohen, R. M., Butera, N. M., Kazemi, E. J., Younes, N., Rosin, S. P., Suratt, C. E., Ahmann, A., Hollander, P. A., Krakoff, J. A., et al. (2024) · Diabetes Care · doi:10.2337/dc23-1782 · Cited by 15
Self-citation
Metadata
- Authors
- Nathan, D. M., Krause-Steinrauf, H., Braffett, B. H., Arends, V. L., Younes, N., McGee, P., Lund, C., Johnson, M., Lorenzi, G., Gao, X., Steffes, M. W., Lachin, J. M., the GRADE Research Group, & the DCCT/EDIC Research Group
- Affiliations
- Harvard University (US)
- George Washington University (US)
- University of Minnesota (US)
- HealthPartners (US)
- University of California San Diego (US)
- Corresponding author
- Krause-Steinrauf, Heidi
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2021-11-15
- Volume
- 16
- Issue
- 11
- Pages
- e0257154
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC8592405
- OpenAlex
- W3211708690
- Semantic Scholar
- 8d4ced1eec0618d0de2678b5a7b4953b3e0d21e3
- Cited by
- 21
- References
- 11
- Citations by year
- 2026: 5 · 2025: 3 · 2024: 4 · 2023: 5 · 2022: 4
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (U01DK098246, U34DK088043, U01 DK094176, U01 DK094157)
- american diabetes association
- national heart, lung, and blood institute
- centers for disease control and prevention
- national eye institute
- national institute of neurological disorders and stroke
- general clinical research centers program
- clinical translational science center program
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- HbA1c, capillary blood collection, venous whole blood, type 1 diabetes, type 2 diabetes, home blood sampling, method comparison
- MeSH terms
- Adult, Aged, Aged, 80 and over, Blood Glucose, Blood Specimen Collection, Capillaries, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Female, Glycated Hemoglobin, Humans, Male, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.