The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Peripheral intravenous catheter insertion and use of ultrasound in patients with difficult intravenous access: Australian patient and practitioner perspectives to inform future implementation strategies
Open accessAbstract
Objective: To understand healthcare worker and patient experience with peripheral intravenous catheter (PIVC) insertion in patients with difficult intravenous access (DIVA) including the use of ultrasound (US). Methods: Descriptive study using 1-on-1 semi-structured interviews conducted between August 2020 and January 2021. Purposeful sampling was used to recruit healthcare practitioners (HCPs) and patients with DIVA who had PIVC experience. Data were analysed using inductive thematic analysis. Interview data were than mapped to the implementation theory Behaviour Change Wheel to inform implementation strategies. Results: In total 78 interviews (13 patients; 65 HCPs) were completed with respondents from metropolitan (60%), regional (25%) and rural/remote (15%) settings across Australia. Thematic analysis revealed 4 major themes: i) Harmful patient experiences persist, with patient insights not leveraged to effect change; ii) ‘Escalation’ is just a word on the front lines; iii) Heightened risk of insertion failure without resources and training; and iv) Paving the way forward–‘measures need to be in place to prevent failed insertion attempts. Themes were mapped to the behaviour change wheel and implementation strategies developed, these included: staff education, e-health record for DIVA identification, DIVA standard of care and DIVA guidelines to support escalation and ultrasound use. Conclusion(s): DIVA patients continue to have poor healthcare experiences with PIVC insertion. There is poor standardisation of DIVA assessment, escalation, US use and clinician education across hospitals. Quality, safety, and education improvement opportunities exist to improve the patient with DIVA experience and prevent traumatic insertions. We identified a number of implementation strategies to support future ultrasound and DIVA pathway implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These divergences could explain the low adoption of DIVA assessment instruments in clinical practice,22 29”
From Difficult intravenous access (DIVA) in the adult population: an umbrella review (2026) · cites this paper as [29]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“the identification of patients with DIVA tends to be somewhat late, after various failed attempts, and many healthcare centres still lack formal mechanisms for its detection and treatment.29 30”
From Difficult intravenous access (DIVA) in the adult population: an umbrella review (2026) · cites this paper as [29]
The cited source says what the claim attributes to it.
In the citing paper
“this practice not always responds to clinical criteria, but tends to be conditioned by structural factors, such as a lack of trained staff or the absence of formal guidelines.29”
From Difficult intravenous access (DIVA) in the adult population: an umbrella review (2026) · cites this paper as [29]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Using thematic analysis in psychology
Braun, V., & Clarke, V. (2006) · Qualitative Research in Psychology · doi:10.1191/1478088706qp063oa · Cited by 194,414 · cited 1×
“Analysis was undertaken as per Braun and Clarke’s six phases of thematic analysis [45].”
MethodTong, A., Sainsbury, P., & Craig, J. (2007) · International Journal for Quality in Health Care · doi:10.1093/intqhc/mzm042 · Cited by 42,509
Designing and Conducting Mixed Methods Research
Robinson, P. (2007) · Australian and New Zealand Journal of Public Health · doi:10.1111/j.1753-6405.2007.00096.x · Cited by 23,258
Qualitative Inquiry and Research Design: Choosing Among Five Approaches
Lewis, S. (2015) · Health Promotion Practice · doi:10.1177/1524839915580941 · Cited by 22,105
How Many Interviews Are Enough?: An Experiment with Data Saturation and Variability
Guest, G., Bunce, A., & Johnson, L. (2006) · Field Methods · doi:10.1177/1525822x05279903 · Cited by 20,808
Palinkas, L. A., Horwitz, S. M., Green, C. A., Wisdom, J. P., Duan, N., & Hoagwood, K. (2015) · Administration and Policy in Mental Health and Mental Health Services Research · doi:10.1007/s10488-013-0528-y · Cited by 12,038 · cited 1×
“We used purposeful sampling [34] and snowballing, to achieve a balanced sample of HCPs with respect to location and discipline.”
MethodWhat's in a name? Qualitative description revisited
Sandelowski, M. (2010) · Research in Nursing & Health · doi:10.1002/nur.20362 · Cited by 4,975 · cited 1×
“We adopted a naturalist philosophy [31] which is concerned with studying something in its natural state rather than applying a specific theoretical perspective.”
MethodBut is it rigorous? Trustworthiness and authenticity in naturalistic evaluation
Lincoln, Y. S., & Guba, E. G. (1986) · New Directions for Program Evaluation · doi:10.1002/ev.1427 · Cited by 3,668
Michie, S., Ashford, S., Sniehotta, F. F., Dombrowski, S. U., Bishop, A., & French, D. P. (2011) · Psychology & Health · doi:10.1080/08870446.2010.540664 · Cited by 1,756
Response Rates and Responsiveness for Surveys, Standards, and the Journal
Fincham, J. E. (2008) · American Journal of Pharmaceutical Education · doi:10.5688/aj720243 · Cited by 1,294 · cited 1×
“Due to the broad dissemination strategy (used to minimise coverage and sampling error [35] we were not able to calculate a denominator and subsequent response rate.”
Research works printed but not linked: 4
- ACSQHC, 2021, Management of Peripheral Intravenous Catheters Clinical Care Standard, 54
- N Marsh, 2018, Expert versus generalist inserters for peripheral intravenous catheter insertion: a pilot randomised controlled trial, Trials, 19, 564, 10.1186/s13063-018-2946-3 · DOI
- SL Norwood, 2010, Research essentials: Foundations for evidence-based practice: Prentice Hall
- SL Norwood, 2010, Research Essential: Foundations for Evidence-Based Practice, New Jersey: Pearson
Cited by
Paterson, R. S., Schults, J. A., Slaughter, E., Cooke, M., Ullman, A., Kleidon, T. M., Keijzers, G., Marsh, N., & Rickard, C. M. (2022) · Emergency Medicine Australasia · doi:10.1111/1742-6723.14069 · Cited by 70
“Even in the ED – where PIVC use is ubiquitous and staff have greater training, escalation to senior staff is more accessible and USG intravenous access is more readily available – clinical guidelines around PIVC insertion decisions to aid emergency clinicians are critical for ensuring high-quality care.(9,19) High-qua…”
BackgroundSelf-citationSchults, J. A., Young, E., Marsh, N. M., Larsen, E. N., Corley, A., Ware, R. S., Murgo, M., Alexandrou, E., McGrail, M. R., Gowardman, J. R., et al. (2024) · Journal of Intensive Care · doi:10.1186/s40560-024-00719-1 · Cited by 32
“Similar to peripheral IV catheter insertion [35, 36] we showed that use of ultrasound for AC insertion was a protective factor against all cause failure, suspected infection, and occlusion [37, 38].”
BackgroundSelf-citationWalker, R., Pires, M. P. D. O., Ray‐Barruel, G., Cooke, M. L., Mihala, G., de Azevedo, S. S., Peterlini, M. A. S., Felipe, M. D. A. A., Álvarez, C. P., Quintanilla, M., et al. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2022.1039232 · Cited by 33
“However, PIVC assessment was documented in the previous 24 h in 65% of cases (6,233).”
BackgroundSelf-citationSchults, J. A., Marsh, N. M., Ullman, A. J., Kleidon, T. M., Ware, R. S., Byrnes, J., Young, E., Hall, L., Keijzers, G., Cullen, L., et al. (2023) · BMC Health Services Research · doi:10.1186/s12913-023-09499-0 · Cited by 17
“The assessment of a patient’s DIVA status is inconsistently performed in practice [16].”
BackgroundInfluentialSelf-citationBroadhurst, D., Cooke, M. L., Sriram, D., Barber, L., Caccialanza, R., Danielsen, M. B., Ebersold, S., Gorski, L., Hirsch, D., Lynch, G., et al. (2023) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000511 · Cited by 15
Self-citationHansen, Ø. M., & Solbakken, R. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-078106 · Cited by 10
“21 22–24 In addition, patients with DIVA report that they encounter a lack of communication and information from nurses during PIVC insertion procedures.”
BackgroundOperation STICK: A vascular access specialty program for the generalist emergency medicine clinician
Bahl, A., Mielke, N., DiLoreto, E., & Gibson, S. M. (2024) · The Journal of Vascular Access · doi:10.1177/11297298231222060 · Cited by 9
Lam, C., Dunstan, L., Sweeny, A. L., Watkins, S., George, S., & Snelling, P. J. (2023) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/ajum.12353 · Cited by 12
Self-citationMatsumoto, M., Tateishi, A., Kobayashi, H., & Hashiguchi, N. (2025) · PLOS One · doi:10.1371/journal.pone.0323367 · Cited by 5
“Failed venipuncture has been associated with difficult intravenous access (DIVA) [6], which delays diagnosis and treatment initiation [7].”
Mielke, N., Xing, Y., Gibson, S. M., DiLoreto, E., & Bahl, A. (2023) · Therapeutics and Clinical Risk Management · doi:10.2147/tcrm.s435628 · Cited by 5
“26 Instead, OSTICK uses the objective vascular access scoring system to guide decision-making.”
MethodA risk prediction model for adult patients with difficult intravenous access
Ji, Y., Liu, C., Cao, X., & Zhao, L. (2025) · The Journal of Vascular Access · doi:10.1177/11297298251314909 · Cited by 10
Godfrey, J., & Gallipoli, L. (2024) · British Journal of Nursing · doi:10.12968/bjon.2024.33.7.s4 · Cited by 8
Patients’ experiences in ultrasound-guided intravenous catheter insertion: a qualitative study
Rivera, R., He, S., McManus, C., Mifflin, N., Tran, T., Harrowell, L., Kuzmins, K., Rihari-Thomas, J., Drury, P., Frost, S. A., et al. (2025) · Enfermería Clínica (English Edition) · doi:10.1016/j.enfcle.2025.102149 · Cited by 3
Xu, H. G., Hyun, A., Kang, E., Marsh, N. M., & Corley, A. (2024) · Australasian Emergency Care · doi:10.1016/j.auec.2024.03.001 · Cited by 4
Self-citationClarke, Z., Lam, C. Y. W., Sweeny, A. L., & Snelling, P. J. (2024) · Journal of Paediatrics and Child Health · doi:10.1111/jpc.16675 · Cited by 2
Self-citationRivera, R., He, S., McManus, C., Mifflin, N., Tran, T., Harrowell, L., Kuzmins, K., Rihari‐Thomas, J., Drury, P., Frost, S. A., et al. (2024) · Enfermería Clínica · doi:10.1016/j.enfcli.2024.09.002 · Cited by 2
Takahashi, T., Nakagami, G., Murayama, R., Abe‐Doi, M., & Sanada, H. (2025) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000595 · Cited by 1
Drugeon, B., Rickard, C. M., Peters, N., Chopra, V., & Mimoz, O. (2025) · Journal of Advanced Nursing · doi:10.1111/jan.70347 · Cited by 2
“Success minimises patient anxiety, pain and caregiver workload, as failure rates can reach 40%, leading to complications like multiple puncture attempts, arterial puncture, hematoma and nerve damage (Schults et al. 2022; Jacobson and Winslow 2005; Taşdelen et al. 2024; van Loon, Buise, et al. 2018).”
InfluentialSelf-citationClinically indicated removal versus routine removal of peripheral venous catheters
Charles, K. R., Schults, J. A., Marsh, N. M., Osborne, S. R., Rees, S., Mihala, G., Smith, S., & Rickard, C. M. (2026) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007798.pub6 · Cited by 1
Self-citationA GAVeCeLT-IVAS bundle for safe insertion of short peripheral catheters: The SISPeC protocol
Pinelli, F., Bastos, R., Miluy, G. O., Scoppettuolo, G., Faraone, V., Annetta, M. G., Brescia, F., Giustivi, D., Elli, S., Gidaro, A., et al. (2026) · The Journal of Vascular Access · doi:10.1177/11297298261442098 · Cited by 1
Difficult intravenous access (DIVA) in the adult population: an umbrella review
Torné-Ruiz, A., Delgado, M., Moreno, S., Corral-Núñez, A., Cemeli, T., & Roca, J. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-121458
Using Simulation Models to Train Clinicians in the Use of Point-of-care Ultrasound
Steinwandel, U. (2024) · Journal of Visualized Experiments · doi:10.3791/66905
Repensar el mundo del manejo del acceso vascular, poniendo un foco en la colaboración
Havers, S. M., & Rickard, C. M. (2025) · Enfermería Clínica · doi:10.1016/j.enfcli.2025.502334
Self-citationRethinking the world of vascular access management with a focus on collaboration
Havers, S. M., & Rickard, C. M. (2025) · Enfermería Clínica (English Edition) · doi:10.1016/j.enfcle.2025.502334
Self-citationSupporting nurses’ transitions to new work practices: A qualitative study
Stohlmann, K. E., Wiig, S., Billett, S. R., & Haraldseid-Driftland, C. (2025) · Nurse Education in Practice · doi:10.1016/j.nepr.2025.104604
Schults, J. A., Marsh, N. M., Ullman, A. J., Kleidon, T. M., Ware, R. S., Byrnes, J., Young, E., Hall, L., Keijzers, G., Cullen, L., et al. (2023) · Figshare · doi:10.6084/m9.figshare.23354455
Self-citationSchults, J. A., Marsh, N. M., Ullman, A. J., Kleidon, T. M., Ware, R. S., Byrnes, J., Young, E., Hall, L., Keijzers, G., Cullen, L., et al. (2023) · Figshare · doi:10.6084/m9.figshare.23354464
Self-citationSchults, J. A., Marsh, N. M., Ullman, A. J., Kleidon, T. M., Ware, R. S., Byrnes, J., Young, E., Hall, L., Keijzers, G., Cullen, L., et al. (2023) · Figshare · doi:10.6084/m9.figshare.23354449
Self-citationSchults, J. A., Young, E., Marsh, N. M., Larsen, E. N., Corley, A., Ware, R. S., Murgo, M., Alexandrou, E., McGrail, M. R., Gowardman, J. R., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26691028
Self-citationSchults, J. A., Marsh, N. M., Ullman, A. J., Kleidon, T. M., Ware, R. S., Byrnes, J., Young, E., Hall, L., Keijzers, G., Cullen, L., et al. (2023) · Figshare · doi:10.6084/m9.figshare.23354461
Self-citationSchults, J. A., Marsh, N. M., Ullman, A. J., Kleidon, T. M., Ware, R. S., Byrnes, J., Young, E., Hall, L., Keijzers, G., Cullen, L., et al. (2023) · Figshare · doi:10.6084/m9.figshare.23354446
Self-citationSchults, J. A., Marsh, N. M., Ullman, A. J., Kleidon, T. M., Ware, R. S., Byrnes, J., Young, E., Hall, L., Keijzers, G., Cullen, L., et al. (2023) · Figshare · doi:10.6084/m9.figshare.23354452
Self-citationSchults, J. A., Marsh, N. M., Ullman, A. J., Kleidon, T. M., Ware, R. S., Byrnes, J., Young, E., Hall, L., Keijzers, G., Cullen, L., et al. (2023) · Figshare · doi:10.6084/m9.figshare.23354458
Self-citationSchults, J. A., Young, E., Marsh, N. M., Larsen, E. N., Corley, A., Ware, R. S., Murgo, M., Alexandrou, E., McGrail, M. R., Gowardman, J. R., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26691025
Self-citationMellander, C., Seifert, S., Hammarskjöld, F., & Taxbro, K. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-113575
Metadata
- Authors
- Schults, J. A., Calleja, P., Slaughter, E., Paterson, R., Rickard, C. M., Booker, C., Marsh, N., Fenn, M., Kelly, J., Snelling, P. J., Byrnes, J., Keijzers, G., & Cooke, M.
- Affiliations
- Griffith University (AU)
- Central Queensland University (AU)
- Metro North Hospital and Health Service (AU)
- The University of Queensland (AU)
- Townsville Hospital (AU)
- Corresponding author
- Schults, Jessica A.
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2022-06-24
- Volume
- 17
- Issue
- 6
- Pages
- e0269788
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC9231778
- OpenAlex
- W4283374992
- Cited by
- 35
- References
- 58
- Citations by year
- 2026: 4 · 2025: 8 · 2024: 10 · 2023: 12 · 2022: 1
- FWCI
- 9.08
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- ResearchOnline - JCU (James Cook University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Bond University Research Portal (Bond University) (submittedVersion, cc-by)
- Griffith Research Online (submittedVersion, cc-by)
- Funders
- national health and medical research council (APP1180193)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
- Keywords
- difficult venous access, peripheral intravenous catheter insertion, ultrasound-guided insertion, patient experience, health professionals' experiences, Behaviour Change Wheel, implementation strategies, insertion failure, treatment escalation, clinician education, rural and remote health services, standard of care
- MeSH terms
- Australia, Catheterization, Peripheral, Humans, Prospective Studies, Catheters, Administration, Intravenous
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.