Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 318

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Determination of Choline, Betaine, and Dimethylglycine in Plasma by a High-Throughput Method Based on Normal-Phase Chromatography–Tandem Mass Spectrometry

Holm, Pål I, Ueland, Per Magne, Kvalheim, Gry, Lien, Ernst A · 2003 · Clinical Chemistry

Abstract

Background: The quaternary ammonium compounds, choline and betaine, and dimethylglycine (DMG) reside along a metabolic pathway linked to the synthesis of neurotransmitters and membrane phospholipids and to homocysteine remethylation and, therefore, folate status. Lack of a convenient, high-throughput method for the determination of these compounds has prevented population-based studies of their possible associations with lifestyle, nutrition, and chronic diseases. Methods: Serum or plasma samples were deproteinized by mixing with three volumes of acetonitrile that contained d9-choline and d9-betaine as internal standards. We used a normal-phase silica column for the separation of choline (retention time, 2.8 min), betaine (1.3 min), DMG (1.15 min), and internal standards, which were detected as positive ions by tandem mass spectroscopy in the multiple-reaction monitoring mode, using the molecular transitions m/z 104→60 (choline), m/z 113→69 (d9-choline), m/z 118→59 (betaine), m/z 127→68 (d9-betaine), and m/z 104→58 (DMG). Results: For all three metabolites, the assay was linear in the range 0.4–400 μmol/L, and the lower limit of the detection (signal-to-noise ratio = 5) was ≤0.3 μmol/L. The within- and between-day imprecision (CVs) was 2.1–7.2% and 3.5–8.8%, respectively. The analytical recovery was 87–105%. The fasting plasma concentrations (median, 25th–75th percentiles) were 8.0 (7.0–9.3) μmol/L for choline, 31.7 (27.0–41.1) μmol/L for betaine, and 1.66 (1.30–2.02) μmol/L for DMG in 60 healthy blood donors. In individuals who had eaten a light breakfast, plasma concentrations of all three metabolites were significantly (25–30%) higher than in fasting individuals. Conclusion: This is the first method for the combined measurement of choline, betaine, and DMG in human plasma or serum. The assay is characterized by simple sample preparation, no derivatization, high throughput, imprecision (CV) <10%, detection limits below the values seen in volunteers, and the high specificity provided by tandem mass spectroscopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/49.2.286

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

Metadata

Authors
Holm, P. I., Ueland, P. M., Kvalheim, G., & Lien, E. A.
Venue
Clinical Chemistry
Published
2003-02-01
Volume
49
Issue
2
Pages
286-294
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2098111113
Cited by
318
References
22
FWCI
2.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.