Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 267

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Evaluation of Human Serum Albumin Cobalt Binding Assay for the Assessment of Myocardial Ischemia and Myocardial Infarction

Open access
Bhagavan, Nadhipuram V, Lai, Ernest M, Rios, Patricia A, Yang, Jinsheng, Ortega-Lopez, Anna M, Shinoda, Hiroko, Honda, Stacey A A, Rios, Carlos N, Sugiyama, Cheryl E, Ha, Chung-Eun · 2003 · Clinical Chemistry

Abstract

Background: Clinical diagnoses were correlated with results of a Co(II)–albumin binding assay in 167 patients treated at an emergency department of a health maintenance organization. Methods: Patients were evaluated as being nonischemic or potentially ischemic through standard coronary disease indicators [creatine kinase (CK), CK-MB, cardiac troponin I, and electrocardiographic findings] and were tested by a Co(II)–albumin binding assay. Samples were tested anonymously, and the study was double-blinded. The sensitivity and specificity of this assay for the detection of ischemia were evaluated by ROC curve analysis. Known Co(II) binding sites on albumin were analyzed by N-terminal amino acid sequencing. Results: The mean absorbance units (ABSU) ± 2 SD for non-myocardial ischemic and myocardial ischemic individuals measured at 470 nm were 0.43 ± 0.10 and 0.63 ± 0.25, respectively (P <0.0001). The area under the ROC curve was 0.95 [95% confidence interval (CI), 0.92–0.99], and at a cutoff value of 0.50 ABSU, sensitivity and specificity were 88% (78–94%) and 94% (86–98%), respectively, suggesting a high distinction between the two groups. When we compared non-acute myocardial infarction (AMI) and AMI ischemic individuals, the area under the ROC curve was 0.66 (95% CI, 0.53–0.79) and was considered a poor discriminator between these two groups. N-Terminal amino acid sequencing data for purified albumin showed normal amino acid residues for six of seven high-ABSU (≥0.70) individuals and one nonischemic individual tested. However, only one individual with a high ABSU (0.80) had two missing amino acid residues (DA) from the N-terminal region. Clinical diagnosis for this patient did not reveal an ischemic event. Conclusions: The Co(II)–albumin binding test may serve as a useful diagnostic tool in emergency facilities for the assessment of myocardial ischemia. High and low ABSU were associated with myocardial ischemic individuals and non-myocardial ischemic individuals, respectively. However, the Co(II)–albumin binding was a poor discriminator between ischemic individuals with and without MI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/49.4.581

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 267

Metadata

Authors
Bhagavan, N. V., Lai, E. M., Rios, P. A., Yang, J., Ortega-Lopez, A. M., Shinoda, H., Honda, S. A. A., Rios, C. N., Sugiyama, C. E., & Ha, C.-E.
Venue
Clinical Chemistry
Published
2003-04-01
Volume
49
Issue
4
Pages
581-585
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2115142726
Cited by
267
References
12
FWCI
11.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.