Partly Nonparametric Approach for Determining the Limit of Detection
The DOI matches its Crossref record.
Abstract
Background: According to recent International Organization for Standardization (ISO) standards, the limit of detection (LoD) of an assay should be estimated taking both type I (α) and II (β) errors into account. The suggested procedure, however, supposes gaussian distributions of both blank and sample measurements and a linear calibration curve. In clinical chemistry, asymmetric, nongaussian blank distributions are common, and the calibration curve may be nonlinear. We present a partly nonparametric procedure that takes these aspects into account. Methods: Using theoretical distribution models and simulation studies, we developed a LoD estimation procedure suitable for the field of clinical chemistry that is partly based on nonparametric statistics. Results: For sample size n, the nonparametrically determined 95th percentile of the blank measurements {obtained as the value of the [n(95/100) + 0.5]th ordered observation} defines the limit for results significantly exceeding zero [limit of blank (LoB)]. The LoD is the lowest value that is likely to yield a result exceeding the LoB. LoD is estimated as: LoB + cβ × SDS, where SDS is the analytical SD of a sample with a low concentration; cβ = z1 − β/[1 − 1/(4 × f)]; z1 − β is the standard normal deviate; and f is the number of degrees of freedom for estimation of SDS. cβ is approximately equal to 1.65 for a type II error of 5%. Approaches and needed tabular values for calculation of confidence limits are presented as well as sample size. Worked examples are given to illustrate estimation and verification of the limit of detection. Simulation results are used to document performance. Conclusion: The proposed procedure appears useful for application in the field of clinical chemistry and promotes a standardized approach for estimating LoDs of clinical chemistry assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037
“05 for not detecting the analyte when it is present, the LOD was derived as: LOB (limit of blank) was defined as the 95 th percentile of the blank A1 sample”
MethodCarr, S. A., Abbatiello, S. E., Ackermann, B. L., Borchers, C., Domon, B., Deutsch, E. W., Grant, R. P., Hoofnagle, A. N., Hüttenhain, R., Koomen, J. M., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.036095 · Cited by 561
Highly Precise Measurement of HIV DNA by Droplet Digital PCR
Strain, M. C., Lada, S. M., Luong, T., Rought, S. E., Gianella, S., Terry, V. H., Spina, C. A., Woelk, C. H., & Richman, D. D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055943 · Cited by 504
Translation of proteomic biomarkers into FDA approved cancer diagnostics: issues and challenges
Füzéry, A. K., Levin, J., Chan, M. M., & Chan, D. W. (2013) · Clinical Proteomics · doi:10.1186/1559-0275-10-13 · Cited by 428
Kessler, L. G., Barnhart, H. X., Buckler, A. J., Choudhury, K. R., Kondratovich, M. V., Toledano, A., Guimaraes, A. R., Filice, R., Zhang, Z., Sullivan, D. C., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537333 · Cited by 293
Self-citation
Metadata
- Authors
- Linnet, K., & Kondratovich, M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-04-01
- Volume
- 50
- Issue
- 4
- Pages
- 732-740
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2123772035
- Cited by
- 103
- References
- 0
- FWCI
- 1.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Partly Nonparametric Approach for Determining the Limit of Detection. https://app.cochat.ai/papers/10.1373/clinchem.2003.029983
- The paper
- Linnet, K., & Kondratovich, M. (2004). Partly Nonparametric Approach for Determining the Limit of Detection. Clinical Chemistry. https://doi.org/10.1373/clinchem.2003.029983
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.