Validation of a New Automated Renin Assay
The DOI matches its Crossref record.
Abstract
Background: Measurement of plasma renin is important for the treatment of patients with congenital adrenal hyperplasia (CAH) and in the evaluation of patients with suspected hyperaldosteronism. Immunologic assays for plasma renin offer easier implementation and standardization than enzyme-kinetic assays for plasma renin activity, but their sensitivity and specificity have been questioned. We studied a renin immunochemiluminescence assay on an automated platform. Methods: Renin was measured by an enzymatic assay, by IRMA, and by the new Nichols Advantage Specialty System immunochemiluminometric assay (ICMA), in plasmas from unselected individuals from our outpatient departments and in samples from patients with selected diagnoses. Results: The detection limit in the ICMA was 0.1 mU/L. The recovery was >90%, and the imprecision (CV) was generally <9%. Mean (SD) concentrations measured by ICMA were 32 (21)% lower than those measured by IRMA. Renin concentrations as measured by ICMA were identical in serum and EDTA-, heparin-, and citrate-anticoagulated plasmas. Prolonged incubation of whole blood at room temperature before centrifugation did not affect renin concentrations. The central 95% interval for 80 healthy adults was 6–85.5 mU/L. Plasma renin as assessed by ICMA in patients with primary hyperaldosteronism was <0.2 mU/L. Conclusions: The performance characteristics of the new renin ICMA allow its use for patients with CAH and for the diagnosis of mineralocorticoid hypertension. In view of the variability of renin concentrations, use for other forms of hypertension or physiologic research calls for the development of uniform sampling protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Graudal, N. A., Hubeck-Graudal, T., & Jurgens, G. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004022.pub4 · Cited by 620
Renin, Prorenin and the Putative (Pro)renin Receptor
Danser, A. H. J., & Deinum, J. (2005) · Hypertension · doi:10.1161/01.hyp.0000186329.92187.2e · Cited by 243
Self-citationMultiple Biomarkers and the Risk of Incident Hypertension
Wang, T. J., Gona, P., Larson, M. G., Levy, D., Benjamin, E. J., Tofler, G. H., Jacques, P. F., Meigs, J. B., Rifai, N., Selhub, J., et al. (2007) · Hypertension · doi:10.1161/01.hyp.0000256956.61872.aa · Cited by 179
Influence of sodium intake and change in sodium intake on plasma-renin in man.
Graudal, N., Hubeck-Graudal, T., & Jurgens, G. (2021) · EClinicalMedicine · doi:10.1016/j.eclinm.2021.100750 · Cited by 29
Bertholf, R. L., Jialal, I., & Winter, W. E. (2012) · Tietz Textbook of Clinical Chemistry and Molecular Diagnostics · doi:10.1016/b978-1-4160-6164-9.00054-8 · Cited by 5
Metadata
- Authors
- de Bruin, R. A., Bouhuizen, A., Diederich, S., Perschel, F. H., Boomsma, F., & Deinum, J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-11-01
- Volume
- 50
- Issue
- 11
- Pages
- 2111-2116
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2137765742
- Cited by
- 44
- References
- 0
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.