Abstract

Background: Homogeneous PCR methods for genotyping usually require fluorescently labeled oligonucleotide probes. Amplicon melting with the DNA dye LCGreen™ I was recently introduced as a closed-tube method of genotyping that does not require probes or real-time PCR. However, some single-nucleotide polymorphisms (SNPs) could not be completely genotyped without addition of a known genotype, and high-resolution melting techniques were necessary. Methods: A 3′-blocked, unlabeled oligonucleotide probe and the saturating dye, LCGreen I, were added to standard PCR reagents before amplification. After PCR, the samples were melted at 0.1–0.3 °C/s in high-resolution (HR-1™), high-throughput (LightTyper™), and rapid-cycle, real-time (LightCycler®) instruments, and fluorescence melting curves were recorded. Results: Derivative melting curves of the probe–target duplexes were characteristic of the genotype under the probe. With synthetic plasmid templates, all SNP base combinations could be genotyped. For human genomic DNA, the technique was demonstrated with mutations associated with cystic fibrosis, including SNPs (G542X, I506V, and F508C) and 3-bp deletions (F508del and I507del). Conclusions: Genotyping of SNPs and small deletions by melting analysis of an unlabeled probe in the presence of LCGreen I is simple and rapid. Only three unlabeled oligonucleotides (two primers and one probe), a saturating DNA dye, PCR, and a melting instrument are required. The method is closed-tube, does not require fluorescently labeled probes or real-time PCR, and can be completed in <10 min on any instrument capable of monitoring melting curves by fluorescence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2004.034322

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 197

Metadata

Authors
Zhou, L., Myers, A. N., Vandersteen, J. G., Wang, L., & Wittwer, C. T.
Venue
Clinical Chemistry
Published
2004-08-01
Volume
50
Issue
8
Pages
1328-1335
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2099630098
Cited by
197
References
2
FWCI
4.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Closed-Tube Genotyping with Unlabeled Oligonucleotide Probes and a Saturating DNA Dye. https://app.cochat.ai/papers/10.1373/clinchem.2004.034322
The paper
Zhou, L., Myers, A. N., Vandersteen, J. G., Wang, L., & Wittwer, C. T. (2004). Closed-Tube Genotyping with Unlabeled Oligonucleotide Probes and a Saturating DNA Dye. Clinical Chemistry. https://doi.org/10.1373/clinchem.2004.034322

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.