Between-Lot Variation in External Quality Assessment of Glucose: Clinical Importance and Effect on Participant Performance Evaluation
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: External quality assessment schemes (EQAS) are conducted to evaluate user performance (participant assessment) and to assess different methods and instruments (method assessment). The quality of control materials is crucial to achieving these goals. Inconsistencies in between-lot variations detected by use of different control and sample materials may affect EQAS outcomes. Methods: For the Accu-Chek Sensor, Precision Xtra, Ascensia Elite, and HemoCue 201 glucometers, 3 different lots of glucose strips were used with each instrument. Method assessment results from analysis of capillary blood and 3 control materials were used to calculate between-lot differences. A simulation study was performed to evaluate the effect of between-lot variation on participant assessment results. Results: With the Precision Xtra, the results obtained with EQA control material mirrored those obtained with capillary blood, but for the other instruments, we found between-lot differences of as much as 1.3 mmol/L, which were substantially greater than those found with capillary blood and of clinical importance at decision limits. The simulation study showed an effect on participant assessment results related to the target values, with the percentage of poor results decreasing (38%, 10%, and 4%) with the use of common, method-specific, and lot-specific target values, respectively. Conclusions: Between-lot variation may influence participant EQA results for participant and method assessments. The clinical relevance of between-lot variation discovered in EQAS using noncommutable control materials should be examined by use of native blood samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skeie, S., Thue, G., Nerhus, K., & Sandberg, S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.7.994 · Cited by 131
Self-citationIFCC recommendation on reporting results for blood glucose
(2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00431-4 · Cited by 110
Kristensen, G. B. B., Nerhus, K., Thue, G., & Sandberg, S. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.031575 · Cited by 68
Self-citation
Cited by
Glucose Measurement: Confounding Issues in Setting Targets for Inpatient Management
Dungan, K., Chapman, J., Braithwaite, S. S., & Buse, J. (2007) · Diabetes Care · doi:10.2337/dc06-1679 · Cited by 292
Freckmann, G., Link, M., Schmid, C., Pleus, S., Baumstark, A., & Haug, C. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0085 · Cited by 46
(2015) · doi:10.1177/1932296815580161 · Cited by 31
Klonoff, D. C., & Reyes, J. S. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700432 · Cited by 29
(2019) · doi:10.1373/clinchem.2018.300202 · Cited by 15
Self-citation
Metadata
- Authors
- Kristensen, G. B., Christensen, N. G., Thue, G., & Sandberg, S.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-09-01
- Volume
- 51
- Issue
- 9
- Pages
- 1632-1636
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2067308906
- Cited by
- 70
- References
- 3
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.