Abstract

In human beings, glucose is distributed like water between erythrocytes and plasma. The molality of glucose (amount of glucose per unit water mass) is the same throughout the sample. Different water concentrations in calibrator, plasma, and erythrocyte fluid can explain some differences that are dependent on sample type, methods requiring sample dilution, and direct reading biosensors detecting molality. Different devices for the measurement of glucose detect and report fundamentally different analytical quantities. The differences exceed the maximum allowable error of glucose determinations for diagnosing and monitoring diabetes mellitus, and they complicate the treatment. The goal of the International Federation of Clinical Chemistry, Scientific Division, Working Group on Selective Electrodes (IFCC-SD WGSE) is to reach a global consensus on reporting results. The document recommends harmonizing to the concentration of glucose in plasma (with the unit mmol/l), irrespective of sample type or technology. A constant factor of 1.11 will convert measured concentration in whole blood to the equivalent concentration in plasma.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0009-8981(01)00431-4

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 14 references

Research works printed but not linked: 3

  1. Siggaard-Andersen, 1987, Physicochemical quantities and units in clinical chemistry with special emphasis on activities and activity coefficients. IUPAC/IFCC recommendation, J. Clin. Chem. Clin. Biochem., 25, 369
  2. Siggaard-Andersen, 1987, Physicochemical quantities and units in clinical chemistry with special emphasis on activities and activity coefficients. IUPAC/IFCC recommendation, Ann. Biol. Clin., 45, 89
  3. 1990, Consensus statement-self monitoring of blood glucose, Diabetes Care, 13, 41

Cited by

See all 115

Metadata

Authors
Working Group on Selective Electrodes Scientific Division
Corresponding author
Working Group on Selective Electrodes Scientific Division
Venue
Clinica Chimica Acta
Publisher
Elsevier BV
Published
2001-05
Volume
307
Issue
1-2
Pages
205-209
ISSN
0009-8981 (ISSN-L)
OpenAlex
W305401523
Cited by
110
References
14
Citations by year
2025: 1 · 2024: 3 · 2023: 6 · 2021: 1 · 2020: 5 · 2019: 3 · 2018: 1 · 2017: 5 · 2016: 7 · 2015: 4 · 2014: 8 · 2013: 4 · 2012: 6
FWCI
2.59
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Clinica Chimica Acta (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
Keywords
blood glucose, plasma glucose, whole blood glucose, sample dilution, diabetes mellitus
MeSH terms
Blood Glucose, Diabetes Mellitus, Humans, Biosensing Techniques, Guidelines as Topic, Clinical Chemistry Tests

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: IFCC recommendation on reporting results for blood glucose. https://app.cochat.ai/papers/10.1016/s0009-8981(01)00431-4
The paper
Working Group on Selective Electrodes Scientific Division. (2001). IFCC recommendation on reporting results for blood glucose. Clinica Chimica Acta. https://doi.org/10.1016/s0009-8981(01)00431-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.