Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 247

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Monitoring Temporary Immunodepression by Flow Cytometric Measurement of Monocytic HLA-DR Expression: A Multicenter Standardized Study

Döcke, Wolf-Dietrich, Höflich, Conny, Davis, Kenneth A, Röttgers, Karsten, Meisel, Christian, Kiefer, Paul, Weber, Stefan U, Hedwig-Geissing, Monika, Kreuzfelder, Ernst, Tschentscher, Peter, Nebe, Thomas, Engel, Andrea, Monneret, Guillaume, Spittler, Andreas, Schmolke, Kathrin, Reinke, Petra, Volk, Hans-Dieter, Kunz, Dagmar · 2005 · Clinical Chemistry

Abstract

Background: Single-center trials have shown that monocytic HLA-DR is a good marker for monitoring the severity of temporary immunodepression after trauma, major surgery, or sepsis. A new test for measuring monocytic HLA-DR is now available. Methods: We evaluated a new test reagent set for monocytic HLA-DR expression (BD Quantibrite™ HLA-DR/Monocyte reagent; Becton Dickinson) in single-laboratory and interlaboratory experiments, assessing preanalytical handling, lyse-no-wash (LNW) vs lyse-wash (LW) values, reference values, and the effect of use of different flow cytometers and different instrument settings on test variance. Results: For preanalytical handling, EDTA anticoagulation, storage on ice as soon as possible, and staining within 4 h after blood collection gave results comparable to values obtained for samples analyzed immediately after collection (mean increase of ∼4% in monocytic HLA-DR). Comparison of LNW and LW revealed slightly higher results for LNW (∼18% higher for LNW compared with LW; r = 0.982). Comparison of different flow cytometers and instrument settings gave CVs <4%, demonstrating the independence of the test from these variables and suggesting that this method qualifies as a standardized test. CV values from the interlaboratory comparison ranged from 15% (blood sample unprocessed before transport) to 25% (stained and fixed before transport). Conclusions: For the BD Quantibrite HLA-DR/Monocyte test, preanalytical handling is standardized. Single-laboratory results demonstrated the independence of this test from flow cytometer and instrument settings. Interlaboratory results showed greater variance than single-laboratory values. This interlaboratory variance was partly attributable to the influence of transport and can be reduced by optimization of transport conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2005.052639

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 247

Metadata

Authors
Döcke, W.-D., Höflich, C., Davis, K. A., Röttgers, K., Meisel, C., Kiefer, P., Weber, S. U., Hedwig-Geissing, M., Kreuzfelder, E., Tschentscher, P., Nebe, T., Engel, A., Monneret, G., Spittler, A., Schmolke, K., Reinke, P., Volk, H.-D., & Kunz, D.
Venue
Clinical Chemistry
Published
2005-12-01
Volume
51
Issue
12
Pages
2341-2347
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2113057501
Cited by
247
References
1
FWCI
3.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.