The DOI matches its Crossref record.
Routine Isotope-Dilution Liquid Chromatography–Tandem Mass Spectrometry Assay for Simultaneous Measurement of the 25-Hydroxy Metabolites of Vitamins D2 and D3
Abstract
Background: Measurement of 25-hydroxyvitamin D2 and D3 (25-OH D2 and D3) is essential for investigating vitamin D deficiency. Competitive binding techniques are unable to distinguish between the 2 metabolites and suffer from interference from other hydroxy metabolites of vitamin D. Methods: We used isotope-dilution liquid chromatography–tandem mass spectrometry (ID-LC-MS/MS) for routine determination of 25-OH D2 and D3 with a stable-isotope–labeled internal standard (IS). Serum samples (100 μL) were denatured with methanol–propanol containing IS, vortex-mixed, extracted into hexane, and dried under nitrogen. The reconstituted extract was chromatographed on a BDS C8 HPLC column, and the metabolites and IS were detected by electrospray ionization MS/MS in multiple-reaction monitoring mode. Results: 25-OH D2 and D3 and the IS nearly coeluted, whereas 1α-hydroxyvitamin D3 was separated; total run time was 8 min. The interassay CVs for 25-OH D2 were 9.5% and 8.4% at 52 and 76 nmol/L, respectively, and for 25-OH D3 were 5.1% and 5.6% at 55 and 87 nmol/L, respectively. The detection limit of the present method was <4 nmol/L for both metabolites. Method comparison with a commercial RIA measuring total 25-hydroxyvitamin D showed good correlation: y = 0.97x − 2.7 nmol/L (r = 0.91). The analytical system can assay 100 samples in 12.5 h. Conclusions: This simple robust interference-free LC-MS/MS assay is suitable for routine measurement of the 25-hydroxy metabolites of vitamins D2 and D3 in human serum. The assay has been in use for 9 months and has been used to assay more than 6000 routine samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bischoff-Ferrari, H. A., Dawson-Hughes, B., Orav, E. J., Staehelin, H. B., Meyer, O. W., Theiler, R., Dick, W., Willett, W. C., & Egli, A. (2016) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.7148 · Cited by 511
Maternal serum vitamin D levels during pregnancy and offspring neurocognitive development
Whitehouse, A. J. O., Holt, B. J., Serralha, M., Holt, P. G., Kusel, M. M. H., & Hart, P. H. (2012) · Pediatrics · doi:10.1542/peds.2011-2644 · Cited by 259
Vitamin D deficiency in pregnancy – still a public health issue
McAree, T., Jacobs, B., Manickavasagar, T., Velagala, S., Brennan, L., Bassett, P., Rainbow, S., & Blair, M. (2013) · Maternal & Child Nutrition · doi:10.1111/mcn.12014 · Cited by 79
Self-citation
Metadata
- Authors
- Maunsell, Z., Wright, D. J., & Rainbow, S. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-09-01
- Volume
- 51
- Issue
- 9
- Pages
- 1683-1690
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2169494016
- Cited by
- 382
- References
- 0
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.