Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 202

The DOI matches its Crossref record.

Novel Isothermal, Linear Nucleic Acid Amplification Systems for Highly Multiplexed Applications

Kurn, Nurith, Chen, Pengchin, Heath, Joe Don, Kopf-Sill, Anne, Stephens, Kathryn M, Wang, Shenglong·2005·Clinical Chemistry

Abstract

Background: Global analysis of the genome, transcriptome, and proteome is facilitated by the recent development of tools for large-scale, highly parallel analysis. We describe a novel nucleic acid amplification system that generates products by several methods. 3′-Ribo-SPIA™ primes cDNA synthesis at the 3′ polyA tail, and whole transcript (WT)-Ribo-SPIA primes cDNA synthesis across the full length of the transcripts and thus provides whole-transcriptome amplification, independent of the 3′ polyA tail. Methods: We developed isothermal linear nucleic acid amplification systems, which use a single chimeric primer, for amplification of DNA (SPIA) and RNA (Ribo-SPIA). The latter allows mRNA amplification from as little as 1 ng of total RNA. Amplification efficiency was calculated based on the delta threshold cycle between nonamplified cDNA targets and amplified cDNA. The amounts and quality of total RNA and amplification products were determined after purification of the amplification products. GeneChip® array gene expression profiling and real-time PCR were used to test the accuracy and reproducibility of the method. Quantification of cDNA products (before and after amplification) at the 2 loci along the transcripts was used to assess product length (for evaluation of the 3′-initiated Ribo-SPIA) and equal representation throughout the length of the transcript (for evaluation of the whole transcript amplification system, WT-Ribo-SPIA™). Results: Ribo-SPIA–based global RNA amplification exhibited linearity over 6 orders of magnitude of transcript abundance and generated microgram amounts of amplified cDNA from as little as 1 ng of total RNA. Conclusions: The described methods enable comprehensive gene expression profiling and analysis from limiting biological samples. The WT-Ribo-SPIA procedure, which enables amplification of non–polyA-tailed RNA, is suitable for amplification and gene expression analysis of both eukaryotic and prokaryotic biological samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2005.053694

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 202

Metadata

Authors
Kurn, N., Chen, P., Heath, J. D., Kopf-Sill, A., Stephens, K. M., & Wang, S.
Venue
Clinical Chemistry
Published
2005-10-01
Volume
51
Issue
10
Pages
1973-1981
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2161877568
Cited by
202
References
0
FWCI
2.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Novel Isothermal, Linear Nucleic Acid Amplification Systems for Highly Multiplexed Applications. https://app.cochat.ai/papers/10.1373/clinchem.2005.053694
The paper
Kurn, N., Chen, P., Heath, J. D., Kopf-Sill, A., Stephens, K. M., & Wang, S. (2005). Novel Isothermal, Linear Nucleic Acid Amplification Systems for Highly Multiplexed Applications. Clinical Chemistry. https://doi.org/10.1373/clinchem.2005.053694

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.