The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review
Abstract
Nucleic Acid Testing (NAT) promises rapid, sensitive and specific diagnosis of infectious, inherited and genetic disease. The next generation of diagnostic devices will interrogate the genetic determinants of such conditions at the point-of-care, affording clinicians prompt reliable diagnosis from which to guide more effective treatment. The complex biochemical nature of clinical samples, the low abundance of nucleic acid targets in the majority of clinical samples and existing biosensor technology indicate that some form of nucleic acid amplification will be required to obtain clinically relevant sensitivities from the small samples used in point-of-care testing (POCT). This publication provides an overview and thorough review of existing technologies for nucleic acid amplification. The different methods are compared and their suitability for POCT adaptation are discussed. Current commercial products employing isothermal amplification strategies are also investigated. In conclusion we identify the factors impeding the integration of the methods discussed in fully automated, sample-to-answer POCT devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA Polymerase
Saiki, R. K., Gelfand, D. H., Stoffel, S., Scharf, S. J., Higuchi, R., Horn, G. T., Mullis, K. B., & Erlich, H. A. (1988) · Science · doi:10.1126/science.2448875 · Cited by 17,719
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Shen, F., Davydova, E. K., Du, W., Kreutz, J. E., Piepenburg, O., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac200247e · Cited by 240
Cited by
Diagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Metadata
- Authors
- Craw, P., & Balachandran, W.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 14
- Pages
- 2469
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2141012160
- Cited by
- 766
- References
- 3
- FWCI
- 21.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review. https://app.cochat.ai/papers/10.1039/c2lc40100b
- The paper
- Craw, P., & Balachandran, W. (2012). Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review. Lab on a Chip. https://doi.org/10.1039/c2lc40100b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.