Effect of Sample Collection Tubes on Cerebrospinal Fluid Concentrations of Tau Proteins and Amyloid β Peptides
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Tau protein and its phosphorylated forms, and amyloid β peptides ending at amino acid 42 (Aβ42) are used as cerebrospinal fluid (CSF) biomarkers of Alzheimer disease (AD) (1)(2)(3)(4)(5)(6)(7)(8). Because preanalytical factors may affect results (4)(9)(10), we measured these biomarkers in CSF samples in collection tubes made of different materials. After approval by the Ethics Committee of the University of Erlangen-Nuremberg, patients and/or their closest relatives gave written informed consent. CSF was obtained from patients (n = 20; mean age, 66 years; 9 women and 11 men) with various neuropsychiatric diseases, including dementias (n = 9), mild cognitive impairment (n = 8), recurrent depression (n = 1), bipolar disorder (n = 1), and emotionally unstable personality (n = 1). We included only CSF samples showing no or only minor contamination with erythrocytes (<150/μL), no intrathecal humoral or cellular immune response, and normal or only slightly disturbed blood–CSF barrier as measured by albumin quotient. After collecting 4–5 mL of CSF for routine analyses, we transferred four 0.5-mL fractions directly into 4 test tubes in this order: (a), polycarbonate (PC; Sarstedt; cat. no. 60.9922.936); (b), a copolymer of polystyrene and acrylonitrile [modified polystyrene (PX); Sarstedt; cat. no. 60.9924.952]; (c), polystyrene (PS; Sarstedt; cat. no. 62.553.542PS); and (d), polypropylene (PP; Sarstedt; cat. no. 62.554.502PP). Fractions were centrifuged simultaneously (1600g for 15 min at room temperature) immediately after the spinal puncture and were frozen at −80 °C within 30–40 min. The material was never thawed and refrozen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Improved discrimination of AD patients using β-amyloid (1-42) and tau levels in CSF
Hulstaert, F., Blennow, K., Ivanoiu, A., Schoonderwaldt, H. C., Riemenschneider, M., Deyn, P. P. D., Bancher, C., Cras, P., Wiltfang, J., Mehta, P. D., et al. (1999) · Neurology · doi:10.1212/wnl.52.8.1555 · Cited by 724
Self-citationEvaluation of CSF-tau and CSF-Aβ42 as diagnostic markers for Alzheimer disease in clinical practice
Andreasen, N., Minthon, L., Davidsson, P., Vanmechelen, E., Vanderstichele, H., Winblad, B., & Blennow, K. (2001) · Archives of Neurology · doi:10.1001/archneur.58.3.373 · Cited by 573
Galasko, D., Chang, L., Motter, R., Clark, C. M., Kaye, J., Knopman, D., Thomas, R., Kholodenko, D., Schenk, D., Lieberburg, I., et al. (1998) · Archives of Neurology · doi:10.1001/archneur.55.7.937 · Cited by 442
Standardization of measurement of β-amyloid(1-42)in cerebrospinal fluid and plasma
Vanderstichele, H., Kerschaver, E. V., Hesse, C., Davidsson, P., Buyse, M.-A., Andreasen, N., Minthon, L., Wallin, A., Blennow, K., & Vanmechelen, E. (2000) · Amyloid · doi:10.3109/13506120009146438 · Cited by 301
Cited by
A consensus protocol for the standardization of cerebrospinal fluid collection and biobanking
Teunissen, C. E., Petzold, A., Bennett, J. L., Berven, F. S., Brundin, L., Comabella, M., Franciotta, D., Frederiksen, J. L., Fleming, J. O., Furlan, R., et al. (2009) · Neurology · doi:10.1212/wnl.0b013e3181c47cc2 · Cited by 845
Picomolar Amyloid-β Positively Modulates Synaptic Plasticity and Memory in Hippocampus
Puzzo, D., Privitera, L., Leznik, E., Fà, M., Staniszewski, A., Palmeri, A., & Arancio, O. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.2692-08.2008 · Cited by 740
“All of the electrophysiological experiments were performed using polypropylene tubing, which has been shown not to alter the ratio of different A fragments (Lewczuk et al., 2006).”
MethodHansson, O., Lehmann, S., Otto, M., Zetterberg, H., & Lewczuk, P. (2019) · Alzheimer's Research & Therapy · doi:10.1186/s13195-019-0485-0 · Cited by 585
Self-citationThe Alzheimer's Association external quality control program for cerebrospinal fluid biomarkers
Mattsson, N., Andreasson, U., Persson, S., Arai, H., Batish, S. D., Bernardini, S., Bocchio‐Chiavetto, L., Blankenstein, M. A., Carrillo, M. C., Chalbot, S., et al. (2011) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2011.05.2243 · Cited by 413
Self-citationMollenhauer, B., Cullen, V., Kahn, I., Krastins, B., Outeiro, T. F., Pepivani, I., Ng, J., Schulz-Schaeffer, W., Kretzschmar, H. A., McLean, P. J., et al. (2008) · Experimental Neurology · doi:10.1016/j.expneurol.2008.06.004 · Cited by 382
Metadata
- Authors
- Lewczuk, P., Beck, G., Esselmann, H., Bruckmoser, R., Zimmermann, R., Fiszer, M., Bibl, M., Maler, J. M., Kornhuber, J., & Wiltfang, J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-02-01
- Volume
- 52
- Issue
- 2
- Pages
- 332-334
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1983874275
- Cited by
- 143
- References
- 4
- FWCI
- 4.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Sample Collection Tubes on Cerebrospinal Fluid Concentrations of Tau Proteins and Amyloid β Peptides. https://app.cochat.ai/papers/10.1373/clinchem.2005.058776
- The paper
- Lewczuk, P., Beck, G., Esselmann, H., Bruckmoser, R., Zimmermann, R., Fiszer, M., Bibl, M., Maler, J. M., Kornhuber, J., & Wiltfang, J. (2006). Effect of Sample Collection Tubes on Cerebrospinal Fluid Concentrations of Tau Proteins and Amyloid β Peptides. Clinical Chemistry. https://doi.org/10.1373/clinchem.2005.058776
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.