CoChat

Sensitive Quantitative Analysis of C-Peptide in Human Plasma by 2-Dimensional Liquid Chromatography–Mass Spectrometry Isotope-Dilution Assay

Rogatsky, Eduard, Balent, Beate, Goswami, Gayotri, Tomuta, Vlad, Jayatillake, Harsha, Cruikshank, Greg, Vele, Louis, Stein, Daniel T · 2006 · Clinical Chemistry
Cited by 47

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Isotope-dilution assays (IDAs) are well established for quantification of metabolites or small drug molecules in biological fluids. Because of their increased specificity, IDAs are an alternative to immunoassays for measuring C-peptide. Methods: We evaluated a 2-dimensional liquid chromatography–mass spectrometry (2D LC/MS) IDA method. Sample preparation was by off-line solid-phase extraction, and C-peptide separation was performed on an Agilent 1100 2D LC system with a purification method based on high-pressure switching between 2 high-resolution reversed-phase columns. Because of the low fragmentation efficiency of C-peptide, multiple-reaction monitoring analysis was omitted and selective-ion monitoring mode was chosen for quantification. Native and isotope-labeled ([M+18] and [M+30]) C-peptides were monitored in the +3 state at m/z 1007.7, 1013.7, and 1017.7. Results: The assay was linear (r2 = 0.9995), with a detection limit of 300 amole (1 pg) on column. Inter- and intraday CVs for C-peptide were ≤2%. Comparison with an established polyclonal-based RIA showed high correlation (r = 0.964). Plasma concentrations of total C-peptide measured by RIA were consistently higher than by IDA LC/MS, consistent with the higher specificity of IDAs compared with immunoassays. Conclusions: The 2D LC/MS IDA approach eliminates matrix effects, enhancing assay performance and reliability, and has a detection limit 100-fold lower than any previously reported LC/MS method. Isotope-labeled C-peptide(s) can be clearly differentiated from endogenous C-peptide by the difference in m/z ratio, so that both peptides can be quantified simultaneously. The method is highly precise, robust, and applicable to pharmacokinetic detection of plasma peptides.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2005.063081

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 47

Metadata

Authors
Rogatsky, E., Balent, B., Goswami, G., Tomuta, V., Jayatillake, H., Cruikshank, G., Vele, L., & Stein, D. T.
Venue
Clinical Chemistry
Published
2006-05-01
Volume
52
Issue
5
Pages
872-879
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2139148927
Cited by
47
References
1
FWCI
1.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitive Quantitative Analysis of C-Peptide in Human Plasma by 2-Dimensional Liquid Chromatography–Mass Spectrometry Isotope-Dilution Assay. https://app.cochat.ai/papers/10.1373/clinchem.2005.063081
The paper
Rogatsky, E., Balent, B., Goswami, G., Tomuta, V., Jayatillake, H., Cruikshank, G., Vele, L., & Stein, D. T. (2006). Sensitive Quantitative Analysis of C-Peptide in Human Plasma by 2-Dimensional Liquid Chromatography–Mass Spectrometry Isotope-Dilution Assay. Clinical Chemistry. https://doi.org/10.1373/clinchem.2005.063081

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.