The DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
The MALDI-TOF Mass Spectrometric View of the Plasma Proteome and Peptidome
Abstract
Background: Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and the related technique, surface-enhanced laser desorption/ionization (SELDI)-TOF MS, are being applied widely to analyze serum or plasma specimens for potential disease markers. Methods: Reports on the basic principles and applications of MALDI-TOF MS were reviewed and related to information on abundance and masses of major plasma proteins. Outcomes: MALDI-TOF MS is a particle-counting method that responds to molar abundance, and ranking of plasma proteins by molar abundance increases the rank of small proteins relative to traditional ranking by mass abundance. Detectors for MALDI-TOF MS augment the bias for detecting smaller components by yielding stronger signals for an equivalent number of small vs large ions. Consequently, MALDI-TOF MS is a powerful tool for surveying small proteins and peptides comprising the peptidome or fragmentome, opening this new realm for analysis. It is complementary to techniques such as electrophoresis and HPLC, which have a bias for detecting larger molecules. Virtually all of the potential markers identified by MALDI-TOF MS to date represent forms of the most abundant plasma proteins. Conclusions: Analyses of serum or plasma by MALDI-TOF MS provide new information mainly about small proteins and peptides with high molar abundance. The spectrum of observed proteins and peptides suggests value for applications such as assessment of cardiovascular risk, nutritional status, liver injury, kidney failure, and systemic immune responses rather than early detection of cancer. Extending analysis by MALDI-TOF MS to lower abundance components, such as markers for early-stage cancers, probably will require more extensive specimen fractionation before analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acute-Phase Proteins and Other Systemic Responses to Inflammation
Gabay, C., & Kushner, I. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902113400607 · Cited by 6,734 · cited 3×
“Concentrations of 1-proteinase inhibitor, 1acid glycoprotein, 1-antichymotrypsin, fibrinogen, and haptoglobin increase more than 2-fold, whereas other components, such as albumin, transferrin, transthyretin, and apolipoproteins, decrease (30, 43, 44).”
BackgroundLaser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Effect of pegylation on pharmaceuticals
Harris, J. M., & Chess, R. B. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1033 · Cited by 3,431
Use of proteomic patterns in serum to identify ovarian cancer
Petricoin, E. F., Ardekani, A. M., Hitt, B. A., Levine, P. J., Fusaro, V. A., Steinberg, S. M., Mills, G. B., Simone, C., Fishman, D. A., Kohn, E. C., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07746-2 · Cited by 3,236
Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,175
Tietz Textbook of Clinical Chemistry
(1999) · Archives of Pathology and Laboratory Medicine · doi:10.5858/123.7.646b · Cited by 2,495
Review on uremic toxins: Classification, concentration, and interindividual variability
Vanholder, R., For the European Uremic Toxin Work Group (EUTox), De Smet, R., Glorieux, G., Argilés, A., Baurmeister, U., Brunet, P., Clark, W., Cohen, G., De Deyn, P. P., et al. (2003) · Kidney International · doi:10.1046/j.1523-1755.2003.00924.x · Cited by 1,720
Ion Suppression in Mass Spectrometry
Annesley, T. M. (2003) · Clinical Chemistry · doi:10.1373/49.7.1041 · Cited by 1,591
Rother, R. P., Bell, L., Hillmen, P., & Gladwin, M. T. (2005) · JAMA · doi:10.1001/jama.293.13.1653 · Cited by 1,557
Cited by
Detailed Identification of Plasma Proteins Adsorbed on Copolymer Nanoparticles
Cedervall, T., Lynch, I., Foy, M., Berggård, T., Donnelly, S. C., Cagney, G., Linse, S., & Dawson, K. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700465 · Cited by 777
Detailed Identification of Plasma Proteins Adsorbed on Copolymer Nanoparticles
Cedervall, T., Lynch, I., Foy, M., Berggård, T., Donnelly, S. C., Cagney, G., Linse, S., & Dawson, K. A. (2007) · Angewandte Chemie · doi:10.1002/ange.200700465 · Cited by 655
Molecular mechanisms of hepatocellular carcinoma
Aravalli, R. N., Steer, C. J., & Cressman, E. N. K. (2008) · Hepatology · doi:10.1002/hep.22580 · Cited by 625
Sparvero, L. J., Asafu-Adjei, D., Kang, R., Tang, D., Amin, N., Im, J., Rutledge, R., Lin, B., Amoscato, A. A., Zeh, H. J., et al. (2009) · Journal of Translational Medicine · doi:10.1186/1479-5876-7-17 · Cited by 622
The blood peptidome: a higher dimension of information content for cancer biomarker discovery
Petricoin, E. F., Belluco, C., Araujo, R. P., & Liotta, L. A. (2006) · Nature Reviews Cancer · doi:10.1038/nrc2011 · Cited by 357
Modeling the Time Evolution of the Nanoparticle-Protein Corona in a Body Fluid
Dell'Orco, D., Lundqvist, M., Oslakovic, C., Cedervall, T., & Linse, S. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010949 · Cited by 337
Hortin, G. L., Sviridov, D., & Anderson, N. L. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.108175 · Cited by 269
Self-citationGAO, H., ZHENG, Z., YUE, Z., LIU, F., ZHOU, L., & ZHAO, X. (2012) · International Journal of Molecular Medicine · doi:10.3892/ijmm.2012.1113 · Cited by 7
Metadata
- Authors
- Hortin, G. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-07-01
- Volume
- 52
- Issue
- 7
- Pages
- 1223-1237
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2112909603
- Cited by
- 351
- References
- 95
- FWCI
- 17.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.