CoChat

Drug Screening of Preserved Oral Fluid by Liquid Chromatography–Tandem Mass Spectrometry

Øiestad, Elisabeth Leere, Johansen, Unni, Christophersen, Asbjorg Solberg · 2007 · Clinical Chemistry
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Oral fluid is an alternative matrix with potential applications in road-side drug screening, work-place testing, drug treatment programs, and epidemiological surveys. Development of methods for extensive drug screening in oral fluid is warranted. Methods: We developed a liquid chromatography– tandem mass spectrometry (LC-MS/MS) method for drug screening of preserved oral fluid collected with the Intercept® collection device. Samples were prepared by liquid–liquid extraction with ethylacetate/heptane (4:1). LC-separation was achieved with an Atlantis dC18-column (2.1 × 50 mm, 3 μm particle). Mass detection was performed by positive ion mode electrospray LC-MS/MS and included the following drugs/metabolites: morphine, 6-monoacetylmorphine, codeine, buprenorphine, methadone, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxyethylamphetamine, cocaine, benzoylecgonine, Δ-9-tetrahydrocannabinol, lysergic acid diethylamide, alprazolam, bromazepam, clonazepam, 7-aminoclonazepam, diazepam, N-desmethyldiazepam, 3-OH-diazepam, fenazepam, flunitrazepam, 7-aminoflunitrazepam, lorazepam, nitrazepam, 7-aminonitrazepam, oxazepam, zopiclone, zolpidem, carisoprodol, and meprobamat. Results: Screening of 32 drugs was performed with a run time of 14 min. Within- and between-day relative CVs varied from 2.0% to 31.8% and from 3.6% to 39.1%, respectively. Extraction recoveries were >50% except for morphine (30%) and benzoylecgonine (0.2%). The concentrations of the lowest calibrator were 1 nmol/L (0.28 μg/L) to 500 nmol/L (68 μg/L), depending on the drug. Conclusion: The method allowed rapid and sensitive oral fluid screening for the most commonly abused drugs in Norway and will be used for a road-side survey of drug use in normal traffic.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2006.074237

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 167

Metadata

Authors
Øiestad, E. L., Johansen, U., & Christophersen, A. S.
Venue
Clinical Chemistry
Published
2007-02-01
Volume
53
Issue
2
Pages
300-309
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2110973023
Cited by
167
References
1
FWCI
15.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.