Evidence for Endotoxin Contamination in Plastic Na+-Heparin Blood Collection Tube Lots
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Biomarker assays are often conducted on whole blood samples in the course of drug development studies. Because bacterial lipopolysaccharide (LPS) (endotoxin) contamination is known to cause spontaneous cytokine production by monocytes, contamination of blood collection tubes may interfere with biomarker assay results. METHODS: Whole blood from healthy donors was collected into plastic or glass sodium (Na+)-heparin Vacutainer™ blood collection tubes and heparinized syringes. Samples were analyzed for phosphoprotein response, cytokine production, and RNA expression. Tubes were tested for endotoxin contamination by use of the limulus amoebocyte lysate assay. RESULTS: Results of phospho-flow cytometry, branched DNA (bDNA), and ELISA assays indicated that a specific lot (#5339582) of plastic Na+-heparin Vacutainer tubes was highly contaminated with an endotoxinlike substance, and contamination was confirmed by the limulus amoebocyte lysate assay. Analysis of multiple-analyte panels revealed that analytes whose changed expression was predictive of LPS stimulation were increased when whole blood was incubated in contaminated tubes for 6 or 18 h. Two additional lots of plastic tubes tested had detectable amounts of endotoxin sufficient to strongly alter phospho-flow cytometry analyses, as determined by the fold change in phosphorylation of p38 mitogen-activated protein kinase in response to tumor necrosis factor α and LPS. In contrast, 3 lots of glass tubes had substantially lower levels of spontaneous blood activation. CONCLUSIONS: Endotoxin contamination associated with tubes from 3 lots of a particular type of plastic Na+-heparin Vacutainer tube dramatically affected biomarker assay measurements. Prescreening these tubes is suggested before their use in clinical sample analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Cited by
Role of Metabolic Endotoxemia in Systemic Inflammation and Potential Interventions
Mohammad, S., & Thiemermann, C. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2020.594150 · Cited by 585
The effect of smoking on chronic inflammation, immune function and blood cell composition
Elisia, I., Lam, V., Cho, B., Hay, M., Li, M. Y., Yeung, M., Bu, L., Jia, W., Norton, N., Lam, S., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-76556-7 · Cited by 263
Influence of Dietary Patterns on Plasma Soluble CD14, a Surrogate Marker of Gut Barrier Dysfunction
Tabung, F. K., Birmann, B. M., Epstein, M. M., Martínez-Maza, O., Breen, E. C., Wu, K., & Giovannucci, E. L. (2017) · Current Developments in Nutrition · doi:10.3945/cdn.117.001396 · Cited by 41
“In addition, LPS contamination of blood collection tubes is common (12), leading to the spurious detection of LPS.”
Effect of age on chronic inflammation and responsiveness to bacterial and viral challenges
Elisia, I., Lam, V., Hofs, E., Li, M. Y., Hay, M., Cho, B., Brooks-Wilson, A., Rosin, M., Bu, L., Jia, W., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0188881 · Cited by 34
Metadata
- Authors
- Newhall, K. J., Diemer, G. S., Leshinsky, N., Kerkof, K., Chute, H. T., Russell, C. B., Rees, W., Welcher, A. A., Patterson, S. D., & Means, G. D.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-09-01
- Volume
- 56
- Issue
- 9
- Pages
- 1483-1491
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2021224403
- Cited by
- 28
- References
- 1
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.