The DOI matches its Crossref record.
Use of the Centaur TnI-Ultra Assay for Detection of Myocardial Infarction and Adverse Events in Patients Presenting With Symptoms Suggestive of Acute Coronary Syndrome
Abstract
Background: We determined the diagnostic accuracy of the Advia Centaur TnI-Ultra assay for detecting myocardial infarction (MI) and assessing risk of adverse events in patients presenting with ischemic symptoms suggestive of acute coronary syndrome. Methods: We measured cardiac troponin I (cTnI) on admission and 6–24 h after admission (follow-up) in plasma specimens from 371 consecutive patients. The end point was the first of cardiac event or death within 60 days. We estimated survival curves using the Kaplan-Meier method and compared groups with the log rank statistic. Results: MI was established in 49 patients (13%). Clinical sensitivities and specificities for MI based on the 99th percentile (0.04 μg/L) were 74% and 84%, respectively, on admission and 94% and 81% at follow-up. ROC curves showed significantly higher accuracy for MI in the follow-up specimen compared with admission (P = 0.001). Overall there were 2 cardiac deaths, 1 noncardiac death, 49 MIs, 7 coronary artery bypass grafts, and 36 percutaneous coronary interventions in 59 patients during follow-up. The event rate in those with cTnI <0.006 μg/L was significantly lower than in groups with cTnI 0.006–0.04 μg/L, >0.04–0.10 μg/L, or >0.10 μg/L (2.8% vs 11.1%, 24.1%, 55.1%, respectively; P <0.0001). Relative risks for the increasing cTnI cutoff groups were 3.9 (95% CI 1.2–13), 8.9 (2.4–34), and 25 (7.3–82) after adjustment for age, diabetes, history of hypertension, previous MI, and estimated glomerular filtration rate. Conclusions: The TnI-Ultra assay is a sensitive, early diagnostic biomarker for MI and an independent predictor of adverse events at any measurable cTnI in patients with symptoms of acute coronary syndrome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Early Diagnosis of Myocardial Infarction with Sensitive Cardiac Troponin Assays
Reichlin, T., Hochholzer, W., Bassetti, S., Steuer, S., Stelzig, C., Hartwiger, S., Biedert, S., Schaub, N., Buerge, C., Potocki, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0900428 · Cited by 1,687
Sensitive Troponin I Assay in Early Diagnosis of Acute Myocardial Infarction
Keller, T., Zeller, T., Peetz, D., Tzikas, S., Roth, A., Czyz, E., Bickel, C., Baldus, S., Warnholtz, A., Fröhlich, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0903515 · Cited by 1,150
Amsterdam, E. A., Kirk, J. D., Bluemke, D. A., Diercks, D., Farkouh, M. E., Garvey, J. L., Kontos, M. C., McCord, J., Miller, T. D., Morise, A., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181ec61df · Cited by 609
Apple, F. S., Ler, R., & Murakami, M. M. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.192716 · Cited by 542
Self-citationSerial Changes in Highly Sensitive Troponin I Assay and Early Diagnosis of Myocardial Infarction
Keller, T., Zeller, T., Ojeda, F., Tzikas, S., Lillpopp, L., Sinning, C., Wild, P., Genth-Zotz, S., Warnholtz, A., Giannitsis, E., et al. (2011) · JAMA · doi:10.1001/jama.2011.1896 · Cited by 509
Metadata
- Authors
- Apple, F. S., Smith, S. W., Pearce, L. A., Ler, R., & Murakami, M. M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-04-01
- Volume
- 54
- Issue
- 4
- Pages
- 723-728
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2155571777
- Cited by
- 163
- References
- 0
- FWCI
- 15.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of the Centaur TnI-Ultra Assay for Detection of Myocardial Infarction and Adverse Events in Patients Presenting With Symptoms Suggestive of Acute Coronary Syndrome. https://app.cochat.ai/papers/10.1373/clinchem.2007.097162
- The paper
- Apple, F. S., Smith, S. W., Pearce, L. A., Ler, R., & Murakami, M. M. (2008). Use of the Centaur TnI-Ultra Assay for Detection of Myocardial Infarction and Adverse Events in Patients Presenting With Symptoms Suggestive of Acute Coronary Syndrome. Clinical Chemistry. https://doi.org/10.1373/clinchem.2007.097162
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.