Background: The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements performed by LC-MS, a clinically available immunoturbidimetric assay, and size-exclusion HPLC. Methods: We obtained unused clinical urine samples from 150 patients who were stratified by degrees of albuminuria (<20 mg/L, 20–250 mg/L, >250 mg/L) as determined by the immunoturbidimetric assay used in our clinical laboratory (Roche Hitachi 912). Urine albumin was then remeasured via LC-MS and HPLC (Accumin™) assays. Results: The immunoturbidimetric assay, calibrated using manufacturer-supplied serum-derived calibrators (Diasorin), underestimated albumin compared with LC-MS. After calibration with purified HSA, this immunoturbidimetric assay correlated well with LC-MS. HPLC overestimated albumin compared with both LC-MS and immunoturbidimetry. The current LC-MS and HPLC assays both performed poorly at concentrations <20 mg/L. Conclusions: Efforts are needed to establish gold-standard traceable calibrators for clinical assays. LC-MS is a specific method to quantify albumin in native urine when concentrations exceed 20 mg/L, and therefore could be employed for standardization among assays.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2008.107508

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The most reliable method is the immunoturbidimetric laboratory assay, which has >95% sensitivity and specificity to detect moderately increased albuminuria.

    “The most reliable method is the immunoturbidimetric laboratory assay, which should be considered the standard for comparison as it has >95% sensitivity and specificity to detect moderately increased albuminuria (505).”

    From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [505]

    The Materials and Methods (IMMUNOASSAY; page unavailable) identify immunoturbidimetry as the laboratory’s routine clinical urine-albumin assay. But the Results (METHOD COMPARISON; page unavailable) report that it underestimated albumin with the supplied calibrators, and the paper gives no >95% diagnostic sensitivity or specificity for detecting moderately increased albuminuria. It does not establish immunoturbidimetry as the most reliable method or the standard for comparison. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Shaikh, A., Seegmiller, J. C., Borland, T. M., Burns, B. E., Ladwig, P. M., Singh, R. J., Kumar, R., Larson, T. S., & Lieske, J. C.
Affiliations
  • Department of Internal Medicine
  • Department of Laboratory Medicine and Pathology
  • Mayo Clinic (US)
Corresponding author
  • Larson, Timothy S
  • Lieske, John C
Venue
Clinical Chemistry
Published
2008-09-01
Volume
54
Issue
9
Pages
1504-1510
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2154993917
Cited by
50
References
24
Citations by year
2025: 1 · 2024: 6 · 2023: 3 · 2022: 4 · 2021: 1 · 2020: 2 · 2019: 1 · 2017: 1 · 2016: 4 · 2015: 3 · 2014: 3 · 2013: 2 · 2012: 2
FWCI
3.85
Type
journal article
Language
en
Open access
Locations
  • Clinical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases (R21DK077669, R01DK076829)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Nephrology › Chronic Kidney Disease and Diabetes
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
Keywords
urinary albumin, albuminuria, immunoturbidimetric assay, size-exclusion HPLC, LC-MS quantification, assay comparison, measurement bias, assay calibration, assay standardization
MeSH terms
Albumins, Albuminuria, Calibration, Chromatography, Gel, Chromatography, High Pressure Liquid, Humans, Immunoassay, Nephelometry and Turbidimetry, Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review