CoChat

Dealing with Missing Predictor Values When Applying Clinical Prediction Models

Janssen, Kristel J M, Vergouwe, Yvonne, Donders, A Rogier T, Harrell, Frank E, Chen, Qingxia, Grobbee, Diederick E, Moons, Karel G M · 2009 · Clinical Chemistry
Cited by 151

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Background: Prediction models combine patient characteristics and test results to predict the presence of a disease or the occurrence of an event in the future. In the event that test results (predictor) are unavailable, a strategy is needed to help users applying a prediction model to deal with such missing values. We evaluated 6 strategies to deal with missing values. Methods: We developed and validated (in 1295 and 532 primary care patients, respectively) a prediction model to predict the risk of deep venous thrombosis. In an application set (259 patients), we mimicked 3 situations in which (1) an important predictor (D-dimer test), (2) a weaker predictor (difference in calf circumference), and (3) both predictors simultaneously were missing. The 6 strategies to deal with missing values were (1) ignoring the predictor, (2) overall mean imputation, (3) subgroup mean imputation, (4) multiple imputation, (5) applying a submodel including only the observed predictors as derived from the development set, or (6) the “one-step-sweep” method. We compared the model’s discriminative ability (expressed by the ROC area) with the true ROC area (no missing values) and the model’s estimated calibration slope and intercept with the ideal values of 1 and 0, respectively. Results: Ignoring the predictor led to the worst and multiple imputation to the best discrimination. Multiple imputation led to calibration intercepts closest to the true value. The effect of the strategies on the slope differed between the 3 scenarios. Conclusions: Multiple imputation is preferred if a predictor value is missing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2008.115345

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 151

Metadata

Authors
Janssen, K. J. M., Vergouwe, Y., Donders, A. R. T., Harrell, F. E., Chen, Q., Grobbee, D. E., & Moons, K. G. M.
Venue
Clinical Chemistry
Published
2009-05-01
Volume
55
Issue
5
Pages
994-1001
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2146668705
Cited by
151
References
11
FWCI
4.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dealing with Missing Predictor Values When Applying Clinical Prediction Models. https://app.cochat.ai/papers/10.1373/clinchem.2008.115345
The paper
Janssen, K. J. M., Vergouwe, Y., Donders, A. R. T., Harrell, F. E., Chen, Q., Grobbee, D. E., & Moons, K. G. M. (2009). Dealing with Missing Predictor Values When Applying Clinical Prediction Models. Clinical Chemistry. https://doi.org/10.1373/clinchem.2008.115345

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.