The DOI matches its Crossref record.
Analytic and Clinical Utility of a Next-Generation, Highly Sensitive Cardiac Troponin I Assay for Early Detection of Myocardial Injury
Abstract
Background: Improvements in cardiac troponin (cTn) assays have increased the rapidity with which clinicians can identify patients with changing cTn concentrations (rise or fall) indicative of acute myocardial injury. The aim of the present study was to characterize a new, high-sensitivity cTnI (hs-cTnI) assay and examine whether increased sensitivity can result in still earlier detection of evolving injury. Methods: We determined the limit of detection, precision profiles, and preliminary estimates of the 99th percentile for the Beckman Coulter hs-cTnI assay in 125 healthy individuals (age <55 years, 54% male). We compared AccuTnI® and hs-cTnI to assess whether change criteria for early concentration changes (i.e., ≥3SD for low concentrations and 20% difference for concentrations >0.10 μg/L) were exceeded in the first 2 specimens (median time between specimens, 1 h; 25th–75th percentile, 1–3 h) from subjects with symptoms suggestive of cardiac ischemia (n = 290). Results: The limit of detection for the hs-cTnI assay was 2.06 ng/L, and the 20% CV and 10% CV concentrations were 2.95 and 8.66 ng/L, respectively. The preliminary 99th percentile estimates in lithium heparin, serum, and EDTA plasma were 9.20, 8.00, and 8.60 ng/L, respectively. In 108 patients with myocardial injury based on the peak AccuTnI concentration, applying the change criteria on the 2 earliest specimens identified 81% (95% CI 73%–88%) of patients using the hs-cTnI assay compared to 62% (53%–71%) using the AccuTnI assay (P < 0.001). Conclusions: Although more extensive validation studies are required, this Beckman Coulter hs-cTnI assay appears to detect patients with evolving myocardial injury earlier.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recommendations for the use of cardiac troponin measurement in acute cardiac care
Thygesen, K., Mair, J., Katus, H., Plebani, M., Venge, P., Collinson, P., Lindahl, B., Giannitsis, E., Hasin, Y., Galvani, M., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq251 · Cited by 628
Self-citationApple, F. S., Ler, R., & Murakami, M. M. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.192716 · Cited by 542
Perioperative Myocardial Injury After Noncardiac Surgery: Incidence, Mortality, and Characterization
Puelacher, C., Lurati Buse, G., Seeberger, D., Sazgary, L., Marbot, S., Lampart, A., Espinola, J., Kindler, C., Hammerer, A., Seeberger, E., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.030114 · Cited by 505
Reichlin, T., Irfan, A., Twerenbold, R., Reiter, M., Hochholzer, W., Burkhalter, H., Bassetti, S., Steuer, S., Winkler, K., Peter, F., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.023937 · Cited by 460
Body, R., Carley, S., McDowell, G., Jaffe, A. S., France, M., Cruickshank, K., Wibberley, C., Nuttall, M., & Mackway-Jones, K. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.026 · Cited by 367
Self-citation
Metadata
- Authors
- Kavsak, P. A., MacRae, A. R., Yerna, M.-J., & Jaffe, A. S.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-03-01
- Volume
- 55
- Issue
- 3
- Pages
- 573-577
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2043147357
- Cited by
- 164
- References
- 0
- FWCI
- 13.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analytic and Clinical Utility of a Next-Generation, Highly Sensitive Cardiac Troponin I Assay for Early Detection of Myocardial Injury. https://app.cochat.ai/papers/10.1373/clinchem.2008.116020
- The paper
- Kavsak, P. A., MacRae, A. R., Yerna, M.-J., & Jaffe, A. S. (2009). Analytic and Clinical Utility of a Next-Generation, Highly Sensitive Cardiac Troponin I Assay for Early Detection of Myocardial Injury. Clinical Chemistry. https://doi.org/10.1373/clinchem.2008.116020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.