The DOI matches its Crossref record; 8 of the 9 references it cites were found in a registry or an index.
Acidification of Blood Is Superior to Sodium Fluoride Alone as an Inhibitor of Glycolysis
Abstract
Background: Sodium fluoride is the preferred agent to inhibit glycolysis. Its action is not immediate, however, and complete inhibition is delayed for up to 4 hours. A more effective method is needed. Acidification of blood combined with the addition of NaF and EDTA appears to be such a method. We studied whether acidification was indeed more effective than NaF. Methods: We conducted 6 independent studies over a 10-month period at 3 Quest Diagnostics laboratory sites. In each study, we drew venous blood from 6–24 nonfasting employee volunteers into 3 or 4 different serum- or plasma-collection tubes, which were stored under different conditions and aliquoted at different times. We analyzed the aliquots in duplicate by means of a hexokinase-based enzymatic method. Results: The mean glucose concentration decreased by 0.3% at 2 h and by 1.2% at 24 h when blood was drawn into tubes containing citrate buffer, NaF, and EDTA. In contrast, the mean glucose concentration decreased by 4.6% at 2 h and by 7.0% at 24 h when blood was drawn into tubes containing NaF and sodium oxalate. Conclusions: Acidification should replace NaF alone as the recommended method for obtaining an accurate glucose concentration. Diagnostic cut points based on blood samples collected into tubes containing NaF as the only inhibitor of glycolysis are likely to be too low.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. A. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,132
Effectiveness of sodium fluoride as a preservative of glucose in blood
Chan, A. Y., Swaminathan, R., & Cockram, C. S. (1989) · Clinical Chemistry · doi:10.1093/clinchem/35.2.315 · Cited by 289
Stabilization of Glucose in Blood Specimens: Mechanism of Delay in Fluoride Inhibition of Glycolysis
Mikesh, L. M., & Bruns, D. E. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.102160 · Cited by 114
M. Stahl, L. G. M. J. (2001) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655101300133612 · Cited by 79
A new method of inhibiting glycolysis in blood samples
Uchida, K., Matuse, R., Toyoda, E., Okuda, S., & Tomita, S. (1988) · Clinica Chimica Acta · doi:10.1016/0009-8981(88)90125-8 · Cited by 53
Waring, W. S., Evans, L. E., & Kirkpatrick, C. T. (2007) · Journal of Clinical Pathology · doi:10.1136/jcp.2006.039925 · Cited by 42
Normal Fasting Plasma Glucose Levels and Type 2 Diabetes
Gambino, R., Reichberg, S. B., & Schwartz, J. G. (2006) · New England Journal of Medicine · doi:10.1056/nejmc052984 · Cited by 8
Self-citation
Cited by
Sorted by citations
Items 101–160 of 160
Quality and Outcome Indicators for Prevention of Type 2 Diabetes In Europe −; IMAGE
Pajunen, P., Landgraf, R., Muylle, F., Neumann, A., Lindström, J., Schwarz, P. E. H., & Peltonen, M. (2010) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 4
Methaemoglobin does not interfere with the analysis of glucose in Terumo Venosafe Glycaemia™tubes
Jones, I., & Böttiger, A. K. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2012.744463 · Cited by 4
und der Deutschen Gesellschaft für Gynäkologie und Geburtshilfe (DGGG )
Kellerer, M., Matthaei, S., Autoren, R. K., Kleinwechter, H. J., Schäfer-Graf, U. M., Bührer, C., Hoesli, I. M., Kainer, F., Kautzky‐Willer, A., Pawlowski, B., et al. (2011) · Cited by 4
Sample processing and specimen misidentification issues
Woodworth, A. L., & Pyle‐Eilola, A. L. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813776-5.00003-0 · Cited by 6
Silkin, Y. A., Silkina, E. N., & Silkin, M. Y. (2021) · Journal of Evolutionary Biochemistry and Physiology · doi:10.1134/s0022093021050033 · Cited by 3
Pemilihan, Penyimpanan dan Stabilitas Sampel Toksikologi pada Korban Penyalahgunaan Narkotika
Manela, C. (2015) · Jurnal Kesehatan Andalas · doi:10.25077/jka.v4i1.243 · Cited by 3
Zhang, L., Ran, Y., Zhu, Y., & Zhen, Q. (2020) · Laboratory Medicine · doi:10.1093/labmed/lmaa051 · Cited by 3
Screening und Diagnostik des Gestationsdiabetes
Koschinsky, T. (2012) · Der Diabetologe · doi:10.1007/s11428-012-0930-1 · Cited by 4
تأثير وقت التخزين ومضادات التخثر المختلفة على مستوى السكر في الدم
Salhen, K. S. A., Saad, E. K., & Aznine, A. J. (2018) · AL-MUKHTAR JOURNAL OF SCIENCES · doi:10.54172/mjsc.v33i2.173 · Cited by 3
Hagman, E. (2016) · Figshare · Cited by 3
Hypoglycaemia, hypoglycorrhachia, neuroglycopenia and glycaemic thresholds
Johnson, P. J. (2018) · Equine Veterinary Education · doi:10.1111/eve.13003 · Cited by 2
Wiriyaprasit, R., Moonla, K., Apiratmateekul, N., Chittamma, A., Kost, G. J., & Treebuphachatsakul, W. (2024) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2024.e00388 · Cited by 2
Nevraumont, A., Deltombe, M., & Bayart, J. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.119875 · Cited by 2
Neonatal Cerebrospinal Fluid Glucose Estimation Using Glucometers
Nirupam, N., Nangia, S., & Saili, A. (2015) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/poc.0000000000000054 · Cited by 2
Prevalence of type 2 diabetes mellitus among adult population of District Srinagar
Sheikh, M. S., Sheikh, I., Khan, S., & Mir, S. (2019) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-018-0704-4 · Cited by 3
Longini, M., Belvisi, E., Leoncini, R., Guerranti, R., & Scapellato, C. (2014) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-013-0047-6 · Cited by 2
Hill, A. N., & Appel, S. J. (2010) · The Nurse Practitioner · doi:10.1097/01.npr.0000388206.16357.02 · Cited by 2
(2012) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0717 · Cited by 2
Sedimentation by Gravity Stabilizes Plasma Glucose for Up to 60 Minutes
Behan, K. J., Johnston, M., & Dumas, M. (2013) · American Society for Clinical Laboratory Science · doi:10.29074/ascls.26.3.158 · Cited by 1
Bonetti, G., Carta, M., Lapolla, A., Miccoli, R., Testa, R., & Mosca, A. (2018) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-018-00203-6 · Cited by 1
Labordiagnostik bei Menschen mit Diabetes
Hörber, S., Heni, M., & Peter, A. (2021) · Der Diabetologe · doi:10.1007/s11428-021-00813-0 · Cited by 1
Maternale Erkrankungen in der Schwangerschaft
Fischer, T., Grab, D., Grubert, T. A., Hantschmann, P., Kainer, F., Kästner, R., Kentenich, C. R. M., Klockenbusch, W., Lammert, F., Louwen, F., et al. (2016) · Elsevier eBooks · doi:10.1016/b978-3-437-23752-2.00017-1 · Cited by 1
Samuel, J. K. R., G, K. V., & Chandrasekaran, S. (2022) · International Journal of Clinical Biochemistry and Research · doi:10.18231/j.ijcbr.2022.041 · Cited by 1
Labordiagnostik bei Diabetes mellitus
Hörber, S., Schleicher, E. D., & Peter, A. (2019) · Diabetologie und Stoffwechsel · doi:10.1055/s-0044-101862 · Cited by 1
Aktuell geltende Leitlinie Gestationsdiabetes
Schäfer-Graf, U. M. (2019) · Der Diabetologe · doi:10.1007/s11428-019-00553-2 · Cited by 1
Sacks, D. B., Arnold, M. A., Metzger, B. E., & Nathan, D. M. (2012) · Cited by 1
Glucose(monitoring): from bench to real world experiences
Fokkert, M. J. (2022) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.207217778 · Cited by 1
Tang, N. (2026) · Annals of Medicine · doi:10.1080/07853890.2026.2654268 · Cited by 1
Quality Management and Outcome Evaluation in Diabetes Prevention
Peltonen, M., & Landgraf, R. (2013) · Wiley eBooks · doi:10.1002/9781118661321.ch9
Neue deutsche Leitlinie zum Gestationsdiabetes: Konsequenzen für die Praxis
Kleinwechter, H. J. (2013) · Journal für Kardiologie (Krause & Pachernegg GmbH)
POCT in der Diabetesdiagnostik
Koschinsky, T., & Wahl, H. G. (2011) · Springer eBooks · doi:10.1007/978-3-642-20172-1_15
Maternale Erkrankungen in der Schwangerschaft
Beinder, E., Fischer, T., Grab, D., Grubert, T. A., Hantschmann, P., Kainer, F., Kästner, R., Kentenich, C. R. M., Klockenbusch, W., Kopp, R., et al. (2012) · Elsevier eBooks · doi:10.1016/b978-3-437-23751-5.10017-2
Effect of Addition of Sodium Citrate in Plasma Extraction for Venous Blood Glucose Determination
Tizziani, T., Siebert, D. A., Pancotte, T., & de Córdova, C. M. M. (2014) · International Journal of Clinical Medicine · doi:10.4236/ijcm.2014.511085 · Cited by 1
Dumoulin, E. N., Hornsby, T., Hemelsoet, D., Delanghe, J., & Stove, V. V. (2012) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0235
Koschinsky, T., & Luppa, P. B. (2012) · Journal of Laboratory Medicine · doi:10.1515/labmed-2012-0008
Könnun á stöðugleika glúkósa í þremur tegundum blóðsýnaglasa
Jónsdóttir, Þ. G., Hjaltadóttir, G., & Þorsteinsdóttir, I. (2012) · Hirsla (Landspítali University Hospital)
Carta, M. (2013) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-013-0028-9
Diabetesdiagnostik einschließlich analytischer Verfahren zur Glukosebestimmung
Wahl, H. G., & Koschinsky, T. (2017) · Springer eBooks · doi:10.1007/978-3-662-54196-8_12
Freckmann, G., Pleus, S., & Baumstark, A. (2019) · Pan African Medical Journal · doi:10.11604/pamj.2019.33.271.19704
Butt, T. M., Masud, K., Khan, J. A., Bhatti, M. S., & Kamran, S. (2016) · Pakistan Armed Forces Medical Journal
Maternale Erkrankungen in der Schwangerschaft
Dröge, L. A., Fischer, T., Grab, D., Grubert, T. A., Hantschmann, P., Henrich, W., Kästner, R., Kainer, F., Kentenich, C. R. M., Klockenbusch, W., et al. (2021) · Elsevier eBooks · doi:10.1016/b978-3-437-23753-9.00017-7
6. Glucose measurement: Technical considerations in laboratory and point-of-care testing
(2015) · International Journal of Gynecology & Obstetrics · doi:10.1016/s0020-7292(15)30014-x
Guder, W. G. (2019) · Springer Reference Medizin · doi:10.1007/978-3-662-48986-4_1294
Guder, W. G. (2017) · Springer eBooks · doi:10.1007/978-3-662-49054-9_1294-1
Pant, V., & Kallner, A. (2022) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-022-01106-y
Yoshimura, R., Kikuchi, Y., Oshiro, K., Araki, H., Iba, H., Furuta, M., Kawachi, M., Kumai, M., & Nomura, S. (2022) · Journal for the Integrated Study of Dietary Habits · doi:10.2740/jisdh.32.4_225
Onyeaghala, A. A., Nurudeen, A. B., Adigun, A., & Babalola, C. P. (2024) · Qeios · doi:10.32388/ubmfgd
Guía práctica sobre la prueba oral de tolerancia a la glucosa
Llanos, I. C., Maselli, M. D. C., & Valdez, S. N. (2024) · Revista de la Sociedad Argentina de Diabetes · doi:10.47196/diab.v58i2.803
Effect of Blood Sample Tubes on Diagnosis of Gestational Diabetes in Pregnant Women Undergoing OGTT
Teksöz, D., Işıksaçan, N., Taşçı, T. S., Kasapoğlu, P., & Koşer, M. (2024) · Muğla Sıtkı Koçman Üniversitesi Tıp Dergisi · doi:10.47572/muskutd.1479380
Laboratory diagnostic changes in diabetes
Friedecky, B., Vávrová, J., & Kratochvíla, J. (2010) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2010.008
Diabetes mellitus - laboratory diagnostics and monitoring of patients state
Friedecky, B., Kratochvíla, J., Springer, D., Prázný, M., & Zima, T. (2016) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2016.008
Diabetes mellitus - laboratory diagnostics and follow-up of patient condition
Friedecky, B., Zima, T., Kratochvíla, J., & Springer, D. (2012) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2012.021
Dunseath, G. J., Luzio, S. D., Cheung, W., Parsons, S. N., John, N., Chokor, M., Atkinson, M., & Peter, R. (2025) · JMIR Diabetes · doi:10.2196/69695
Diabetes mellitus - laboratory diagnostics and patient status monitoring
Friedecky, B., Kratochvíla, J., Springer, D., Prázný, M., Pelikánová, T., Zima, T., & Racek, J. (2019) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2019.007
Maternale Erkrankungen in der Schwangerschaft
Fischer, T., Grab, D., Grubert, T. A., Hantschmann, P., Henrich, W., Kästner, R., Kainer, F., Kentenich, C. R. M., Lammert, F., Lorenz-Meyer, L. A., et al. (2025) · Elsevier eBooks · doi:10.1016/b978-3-437-21097-6.00017-2
Spry, E. P., Jamieson, E. L., Anderson, L., Hoey, M. A., Kirke, A. B., & Marley, J. V. (2025) · Research Square · doi:10.21203/rs.3.rs-7316550/v1
Apparent gluco-concentration with citrate tubes is not a result of water uptake by erythrocytes
Potter, J. M., Pratt, J., D'Souza, M., Naumovski, J., Yosar, J., Hickman, P. E., & Salib, M. M. (2025) · Pathology · doi:10.1016/j.pathol.2025.09.010
Analytische Verfahren zur Glukosebestimmung und Diabetesdiagnostik
Pleus, S., Petersmann, A., & Freckmann, G. (2025) · Springer eBooks · doi:10.1007/978-3-662-71315-0_12
Flindt, J., Radziewitz, M., Müller, A., Harnack, S., & Schwarz, A. (2026) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2026.e00534
An evaluation of factors that affect glycaemic control and its measurements in diabetes mellitus
Ng, J. M. (2010) · Repository@Hull (Worktribe) (University of Hull)
Metadata
- Authors
- Gambino, R., Piscitelli, J., Ackattupathil, T. A., Theriault, J. L., Andrin, R. D., Sanfilippo, M. L., & Etienne, M.
- Affiliations
- Quest Diagnostics (United States) (US)
- Teterboro, NJ
- West Hills, CA, and
- Miramar, FL
- Corresponding author
- Gambino, Raymond
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-05-01
- Volume
- 55
- Issue
- 5
- Pages
- 1019-1021
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2156782964
- Cited by
- 160
- References
- 9
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 8 · 2023: 4 · 2022: 5 · 2021: 9 · 2020: 10 · 2019: 12 · 2018: 13 · 2017: 10 · 2016: 14 · 2015: 11 · 2014: 9 · 2013: 12 · 2012: 16
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Clinical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Keywords
- sodium fluoride, glycolysis inhibition, EDTA, sodium oxalate, blood collection tubes, serum glucose, plasma glucose, blood sample storage, diagnostic thresholds
- MeSH terms
- Blood, Blood Glucose, Blood Preservation, Citrates, Diabetes Mellitus, Glycolysis, Humans, Hydrogen-Ion Concentration, Sodium Fluoride, Specimen Handling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review