The DOI matches its Crossref record; 8 of the 9 references it cites were found in a registry or an index.
Acidification of Blood Is Superior to Sodium Fluoride Alone as an Inhibitor of Glycolysis
Abstract
Background: Sodium fluoride is the preferred agent to inhibit glycolysis. Its action is not immediate, however, and complete inhibition is delayed for up to 4 hours. A more effective method is needed. Acidification of blood combined with the addition of NaF and EDTA appears to be such a method. We studied whether acidification was indeed more effective than NaF. Methods: We conducted 6 independent studies over a 10-month period at 3 Quest Diagnostics laboratory sites. In each study, we drew venous blood from 6–24 nonfasting employee volunteers into 3 or 4 different serum- or plasma-collection tubes, which were stored under different conditions and aliquoted at different times. We analyzed the aliquots in duplicate by means of a hexokinase-based enzymatic method. Results: The mean glucose concentration decreased by 0.3% at 2 h and by 1.2% at 24 h when blood was drawn into tubes containing citrate buffer, NaF, and EDTA. In contrast, the mean glucose concentration decreased by 4.6% at 2 h and by 7.0% at 24 h when blood was drawn into tubes containing NaF and sodium oxalate. Conclusions: Acidification should replace NaF alone as the recommended method for obtaining an accurate glucose concentration. Diagnostic cut points based on blood samples collected into tubes containing NaF as the only inhibitor of glycolysis are likely to be too low.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. A. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,132
Effectiveness of sodium fluoride as a preservative of glucose in blood
Chan, A. Y., Swaminathan, R., & Cockram, C. S. (1989) · Clinical Chemistry · doi:10.1093/clinchem/35.2.315 · Cited by 289
Stabilization of Glucose in Blood Specimens: Mechanism of Delay in Fluoride Inhibition of Glycolysis
Mikesh, L. M., & Bruns, D. E. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.102160 · Cited by 114
M. Stahl, L. G. M. J. (2001) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655101300133612 · Cited by 79
A new method of inhibiting glycolysis in blood samples
Uchida, K., Matuse, R., Toyoda, E., Okuda, S., & Tomita, S. (1988) · Clinica Chimica Acta · doi:10.1016/0009-8981(88)90125-8 · Cited by 53
Waring, W. S., Evans, L. E., & Kirkpatrick, C. T. (2007) · Journal of Clinical Pathology · doi:10.1136/jcp.2006.039925 · Cited by 42
Normal Fasting Plasma Glucose Levels and Type 2 Diabetes
Gambino, R., Reichberg, S. B., & Schwartz, J. G. (2006) · New England Journal of Medicine · doi:10.1056/nejmc052984 · Cited by 8
Self-citation
Cited by
Sorted by citations
International Expert Committee report on the role of the A1c assay in the diagnosis of diabetes
The International Expert Committee (2009) · Diabetes Care · doi:10.2337/dc09-9033 · Cited by 3,185
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Hod, M., Kapur, A., Sacks, D. A., Hadar, E., Agarwal, M., Di Renzo, G. C., Roura, L. C., McIntyre, H. D., Morris, J. L., & Divakar, H. (2015) · International Journal of Gynecology & Obstetrics · doi:10.1016/s0020-7292(15)30033-3 · Cited by 767
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
A European Evidence-Based Guideline for the Prevention of Type 2 Diabetes
Paulweber, B., Valensi, P. E., Lindström, J., Lalic, N. M., Greaves, C. J., McKee, M., Kissimova‐Skarbek, K., Liatis, S., Cosson, E., Szendroedi, J., et al. (2010) · Hormone and Metabolic Research · doi:10.1055/s-0029-1240928 · Cited by 485
A1c versus glucose testing: a comparison
Sacks, D. B. (2011) · Diabetes Care · doi:10.2337/dc10-1546 · Cited by 461
Principles of fluoride toxicity and the cellular response: a review
Johnston, N. R., & Strobel, S. A. (2020) · Archives of Toxicology · doi:10.1007/s00204-020-02687-5 · Cited by 356
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
“Loss of glucose can be minimized in two classic ways: 1) immediate separation of plasma from blood cells after blood collection [the glucose concentration is stable for 8 h at 25°C and 72 h at 4°C in separated, nonhemolyzed, sterile serum without fluoride (61)]; and 2) placing the blood tube in an ice–water slurry imm…”
Impact of blood collection devices on clinical chemistry assays
Bowen, R. A. R., Hortin, G. L., Csákó, G., Otañez, O. H., & Remaley, A. T. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.10.001 · Cited by 241
Sacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 164
Stabilization of glucose in blood samples: why it matters
Bruns, D. E., & Knowler, W. C. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.126037 · Cited by 125
Seclen, S. N., Rosas, M. E., Arias, A. J., Huayta, E. C. N. Q., & Medina, C. A. (2015) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2015-000110 · Cited by 114
Luppa, P. B., Bietenbeck, A., Beaudoin, C. A., & Giannetti, A. E. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.01.003 · Cited by 90
Potter, J. M., Hickman, P. E., Oakman, C., Woods, C., & Nolan, C. J. (2020) · Diabetes Care · doi:10.2337/dc20-0304 · Cited by 71
Sample management for clinical biochemistry assays: Are serum and plasma interchangeable specimens?
Lima-Oliveira, G., Monneret, D., Guerber, F., & Guidi, G. C. (2018) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1499708 · Cited by 58
Rioja, R. G., Martínez, D., Segovia, M., Ibarz, M., Llopis, M. A., Bauçà, J. M., Marzana, I., Barba, N., Ventura, M., del Pino, I. G., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1189 · Cited by 56
Sodium fluoride: an ineffective inhibitor of glycolysis
Gambino, R. (2012) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2012.012135 · Cited by 50
Self-citationStability of glucose in plasma with different anticoagulants
Fobker, M. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-1049 · Cited by 47
It takes acid, rather than ice, to freeze glucose
van den Berg, S. A. A., Thelen, M. H. M., Salden, L. P. W., van Thiel, S. W., & Boonen, K. J. M. (2015) · Scientific Reports · doi:10.1038/srep08875 · Cited by 49
What is the most suitable blood collection tube for glucose estimation?
Dimeski, G., Yow, K. S., & Brown, N. N. (2014) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563214544708 · Cited by 50
Quality Indicators for the Prevention of Type 2 Diabetes in Europe – IMAGE
Pajunen, P., Landgraf, R., Muylle, F., Neumann, A., Lindström, J., Schwarz, P. E. H., Peltonen, M., Acosta, T., Adler, M., Alkerwi, A., et al. (2010) · Hormone and Metabolic Research · doi:10.1055/s-0029-1240976 · Cited by 49
Turchiano, M., Nguyen, C., Fierman, A., Lifshitz, M., & Convit, A. (2013) · Journal of Environmental and Public Health · doi:10.1155/2013/256151 · Cited by 46
Bowen, R. A. R., & Adcock, D. M. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.10.004 · Cited by 44
Balicco, A., Oleko, A., Szego, E., Boschat, L., Deschamps, V., Saoudi, A., Zeghnoun, A., & Fillol, C. (2017) · Annales de Toxicologie Analytique · doi:10.1016/j.toxac.2017.06.003 · Cited by 42
Which sample tube should be used for routine glucose determination?
Bonetti, G., Cancelli, V., Coccoli, G., Piccinelli, G., Brugnoni, D., Caimi, L., & Carta, M. (2015) · Primary care diabetes · doi:10.1016/j.pcd.2015.11.003 · Cited by 39
Glucose measurement in body fluids: A ready reckoner for clinicians
Kubihal, S., Goyal, A., Gupta, Y., & Khadgawat, R. (2020) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2020.11.021 · Cited by 40
Hahnefeld, L., Gurke, R., Thomas, D., Schreiber, Y., Schäfer, S. M. G., Trautmann, S., Snodgrass, I. F., Kratz, D., Geißlinger, G., & Ferreirós, N. (2019) · Talanta · doi:10.1016/j.talanta.2019.120593 · Cited by 37
Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results
Pasqualetti, S., Braga, F., & Panteghini, M. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.03.009 · Cited by 41
It’s Time for a Better Blood Collection Tube to Improve the Reliability of Glucose Results
Peake, M. J., Bruns, D. E., Sacks, D. B., & Horvath, A. R. (2012) · Diabetes Care · doi:10.2337/dc12-1312 · Cited by 37
Citric/citrate buffer: an effective antiglycolytic agent
del Pino, I. G., Constanso, I. P., Mourín, L. V., Safont, C. B., & Vázquez, P. R. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0735 · Cited by 34
Fernandez, L., Jee, P., Klein, M.-J., Fischer, P. Q., Perkins, S. L., & Brooks, S. P. J. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.11.027 · Cited by 33
Italian joint SIBioC-SIPMeL Study Group on Diabetes Mellitus, Bonetti, G., Carta, M., Montagnana, M., Cascio, C. L., Bonfigli, A. R., Mosca, A., & Testa, R. (2016) · Biochemia Medica · doi:10.11613/bm.2016.006 · Cited by 32
Blood Glucose Determination: Effect of Tube Additives
(2018) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2017.12.003 · Cited by 28
Diagnosis of gestational diabetes mellitus will be flawed until we can measure glucose
Bruns, D. E., Metzger, B. E., & Sacks, D. B. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz027 · Cited by 30
Relative efficacy of different strategies for inhibition of in vitro glycolysis
Fischer, M. M., Hannemann, A., Winter, T., Schäfer, C., Petersmann, A., & Nauck, M. (2021) · Clinical Chemistry · doi:10.1093/clinchem/hvab071 · Cited by 28
Carey, R., Lunt, H., Heenan, H. F., Frampton, C. M. A., & Florkowski, C. M. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.05.017 · Cited by 26
Bennett, K. A., Turner, L. M., Millward, S., Moss, S. E. W., & Hall, A. J. (2017) · Conservation Physiology · doi:10.1093/conphys/cox013 · Cited by 26
Seclen, S. N., Rosas, M. E., Arias, A. J., & Medina, C. A. (2017) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2017-000401 · Cited by 26
Technical and clinical validation of the Greiner FC-Mix glycaemia tube
van der Hagen, E. A. E., Fokkert, M. J., Kleefman, A. M. D., Thelen, M., van den Berg, S. A. A., & Slingerland, R. J. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0944 · Cited by 25
Juričić, G., Bakliža, A., Saračević, A., Kopčinović, L. M., Dobrijević, S., Drmić, S., & Šimundić, A.-M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0746 · Cited by 24
Borg, R., Persson, F., Siersma, V., Lind, B., Olivarius, N. D. F., & Andersen, C. L. (2018) · Diabetic Medicine · doi:10.1111/dme.13776 · Cited by 24
Mansouri, K., Rastegari‐Pouyani, M., Ghanbari-Movahed, M., Safarzadeh, M., Kiani, S., & Ghanbari‐Movahed, Z. (2020) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2020.110694 · Cited by 24
Jamieson, E. L., Dimeski, G., Flatman, R., Hickman, P. E., Jones, G. R. D., Marley, J. V., McIntyre, D. H., McNeil, A. R., Nolan, C. J., Potter, J. M., et al. (2022) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.10.002 · Cited by 24
Juričić, G., Kopčinović, L. M., Saračević, A., Bakliža, A., & Šimundić, A.-M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0358 · Cited by 23
IMPORTANCE OF THE PRE-ANALYTICAL PHASE IN BLOOD GLUCOSE ANALYSIS
Janssen, K., & Delanghe, J. (2010) · Acta Clinica Belgica · doi:10.1179/acb.2010.068 · Cited by 21
Norman, M., & Jones, I. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.01.011 · Cited by 22
Ridefelt, P., Åkerfeldt, T., & Helmersson-Karlqvist, J. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.02.022 · Cited by 21
Point‐of‐care glucose monitoring on the neonatal unit
Makaya, T., Memmott, A., & Bustani, P. (2011) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.2011.02253.x · Cited by 21
Stapleton, M., Daly, N., O’Kelly, R., & Turner, M. J. (2017) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563216682978 · Cited by 21
Bietenbeck, A., Geilenkeuser, W. J., Klawonn, F., Spannagl, M., Nauck, M., Petersmann, A., Thaler, M., Winter, C., & Luppa, P. B. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1142 · Cited by 20
Fast test: Clinical practice and interpretation
Agin, A., Charrié, A., Chikh, K., Tabarin, A., & Vezzosi, D. (2013) · Annales d Endocrinologie · doi:10.1016/j.ando.2013.05.003 · Cited by 20
Stabilization of glucose in blood samples: out with the old, in with the new
Gambino, R., & Bruns, D. E. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0341 · Cited by 20
Self-citationDaly, N., Flynn, I., Carroll, C., Stapleton, M., O'Kelly, R., & Turner, M. J. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2016.254466 · Cited by 19
An important source of preanalytical error in medical laboratories: centrifugation
Sönmez, Ç., Gümüş, A., Şeneş, M., Aykal, G., Taneli, F., Aksungar, F. B., Avcı, E., Coşkun, C., Çınaroğlu, İ., Çolak, A., et al. (2021) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2020-0262 · Cited by 19
Using glycated hemoglobin hba1c for diagnosis of diabetes mellitus: an indian perspective
Mahajan, R. D., & Mishra, B. (2011) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 19
Roy, D. R., Dzyuba, B., Policar, T., Malinovskyi, O., Rodina, M., & Dzyuba, V. (2021) · Biology · doi:10.3390/biology10080739 · Cited by 18
Validity of two point-of-care glucometers in the diagnosis of neonatal hypoglycemia
Ngerncham, S., Piriyanimit, S., Kolatat, T., Wongsiridej, P., Inchgarm, L., Kitsommart, R., Vutrapongwatana, P., & Jeerapaet, K. (2012) · Indian Pediatrics · doi:10.1007/s13312-012-0133-2 · Cited by 18
Nielsen, C., Pedersen, L. T., Lindholt, J. S., Mortensen, F. V., & Erlandsen, E. J. (2011) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2011.590900 · Cited by 18
Long-term stability of glucose: 96-h study using Terumo Glycaemia tubes
Winter, T., Greiser, A., Nauck, M., & Petersmann, A. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0548 · Cited by 18
Perlee, D., van der Steege, K. H., & den Besten, G. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0513 · Cited by 15
Gowda, G. A. N., Pascua, V., Hill, L., Djukovic, D., Wang, D. Y. Q., & Raftery, D. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c03719 · Cited by 15
Landberg, E., Nevander, S., Hadi, M. A., Blomberg, M. I., Norling, A., Ekman, B., & Lilliecreutz, C. (2021) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2021.1980224 · Cited by 15
Long-term stability of glucose: glycolysis inhibitor vs. gel barrier tubes
Winter, T., Hannemann, A., Suchsland, J., Nauck, M. A., & Petersmann, A. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0860 · Cited by 14
A Potential Issue with Screening Prediabetes or Diabetes Using Serum Glucose: A Delay in Diagnosis
Kang, J. G., Park, C., Ihm, S., & Park, S. W. (2016) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2016.40.5.414 · Cited by 13
Are fluoride-containing blood tubes still needed for glucose testing?
Bruns, D. E. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2013.01.009 · Cited by 13
Bonetti, G., Carta, M., Lapolla, A., Miccoli, R., Testa, R., & Mosca, A. (2018) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2018.09.013 · Cited by 13
Chan, H., Lunt, H., Thompson, H., Heenan, H. F., FRAMPTON, C. M. A., & Florkowski, C. M. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-1059 · Cited by 13
Inhibition of Glycolysis for Glucose Estimation in Plasma: Recent Guidelines and their Implications
Gupta, S. D., & Kaur, H. (2013) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-013-0405-1 · Cited by 12
Juričić, G., Saračević, A., Kopčinović, L. M., Bakliža, A., & Šimundić, A.-M. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.03.006 · Cited by 13
Saračević, A., Dukić, L., Juričić, G., Kopčinović, L. M., Mirošević, G., & Šimundić, A.-M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0279 · Cited by 13
A Comparison of Fasting Glucose and HbA1c for the Diagnosis of Diabetes Mellitus Among Korean Adults
Yun, W.-J., Shin, M., Kweon, S.-S., Park, K.-S., Lee, Y. H., Nam, H., Jeong, S., Yun, Y.-W., & Choi, J. (2010) · Journal of Preventive Medicine and Public Health · doi:10.3961/jpmph.2010.43.5.451 · Cited by 10
Stability of Glucose Concentrations in Frozen Plasma
Pleus, S., Freckmann, G., Baumstark, A., & Haug, C. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820963657 · Cited by 10
Importance and Status of HBA1C in T2DM and its Indian Perspective
Sarmah, D., & Sharma, B. (2012) · Asian journal of biomedical and pharmaceutical sciences · doi:10.15272/ajbps.v2i12.60 · Cited by 10
Al-Kharusi, A., Al-Lawati, N., Al-Kindi, M., & Mula-Abed, W.-A. S. (2014) · Oman Medical Journal · doi:10.5001/omj.2014.109 · Cited by 10
Bonetti, G., & Carta, M. (2017) · Biochemia Medica · doi:10.11613/bm.2017.030901 · Cited by 10
Kristensen, K. H., Wangel, A., Katsarou, A., Shaat, N., Simmons, D. S., Fadl, H., & Berntorp, K. E. (2020) · Journal of Diabetes Research · doi:10.1155/2020/7937403 · Cited by 10
Kellerer, M., Schäfer-Graf, U. M., & Neonatologie, K. F. (2016) · Cited by 9
Szőke, D., Borille, S., Cardellicchio, M., Spadaccini, G., Taricco, E., Vignali, M., Cetin, I., Birindelli, S., & Panteghini, M. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0706 · Cited by 9
Gupta, S., Gupta, A., Verma, M., Singh, K., Kaur, A., Chopra, B., & Kaur, V. (2016) · International Journal of Applied and Basic Medical Research · doi:10.4103/2229-516x.174010 · Cited by 8
Stabilization of Plasma Glucose: The Use of Newer Technology and Pragmatic Laboratory Practice
Coward, S. M., O'Neill, F. C., McAdam, L., Reilly, L., & McKeeman, G. C. (2018) · The Journal of Applied Laboratory Medicine · doi:10.1373/jalm.2018.027227 · Cited by 8
Steele, A. M., Wensley, K. J., Brewer, E., Shields, B. M., Hattersley, A. T., & McDonald, T. J. (2013) · Practical Diabetes · doi:10.1002/pdi.1758 · Cited by 8
Thermometric analysis of blood metabolites in ICU patients
Adlerberth, J., Meng, Q., Mecklenburg, M., Tian, Z., Zhou, Y., Bülow, L., & Xie, B. (2019) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-019-08873-7 · Cited by 7
Stolz, M., Schlawne, C., Hoffmann, J., Hartmann, V., Marini, I., Fritsche, A., Peter, A., Bakchoul, T., & Schick, F. (2020) · NMR in Biomedicine · doi:10.1002/nbm.4358 · Cited by 7
Haeckel, R., Wosniok, W., Torge, A., Junker, R., Bertram, A., Krebs, A., Özcürümez, M. K., Orth, M., & Streichert, T. (2020) · Journal of Laboratory Medicine · doi:10.1515/labmed-2020-0064 · Cited by 7
Segerer, H., Bührer, C., Kapellen, T. M., Mattern, E., Ramsauer, B., SOMVILLE, T., & Trotter, A. (2018) · Zeitschrift für Geburtshilfe und Neonatologie · doi:10.1055/a-0628-0873 · Cited by 7
Glucose sampling: importance of citrate
Carta, M., Montagnana, M., Cascio, C. L., Bonetti, G., & on behalf of the Italian joint SIBioC-SIPMeL study group on diabetes mellitus (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563216645621 · Cited by 6
Time Is Glucose, Can't Miss Gestational Diabetes
Festa, R., Carta, M., Ceriello, A., & Testa, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0225 · Cited by 6
Ohnmacht, C. M., Cooley, M., Darling, R. J., Lei, S., & Patel, V. (2019) · Bioanalysis · doi:10.4155/bio-2019-0238 · Cited by 6
Heilmann, G., Trenkamp, S., Möser, C., Bombrich, M., Schön, M., Yurchenko, I., Straßburger, K., Rodríguez, M. M., Zaharia, O., Burkart, V., et al. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0770 · Cited by 5
Maintaining glucose integrity ex-vivo: Impact of preanalytical specimen handling
Islam, M. N., Lyons, C., Griffin, T. P., Hamon, S., Dunne, F., & O’Shea, P. M. (2023) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632231199374 · Cited by 6
Should haemoglobin A1cbe used for the diagnosis of diabetes mellitus in South Africa?
George, J. A. (2011) · Journal of Endocrinology Metabolism and Diabetes of South Africa · doi:10.1080/22201009.2011.10872263 · Cited by 5
Diabetes diagnostics including analytical methods for glucose monitoring
Wahl, H. G., & Koschinsky, T. (2018) · Springer eBooks · doi:10.1007/978-3-662-54497-6_12 · Cited by 5
Preanalytical issues related to routine and diagnostic glucose tests: Results from a survey in Spain
del Pino, I. G., Ibarz, M., Rioja, R. G., Salas, P., Segovia, M., Puente, J. J., Marzana, I., Ventura, M., Martínez, D., Llopis, M. A., et al. (2019) · Biochemia Medica · doi:10.11613/bm.2020.010704 · Cited by 8
Dibbasey, M., Umukoro, S., & Bojang, A. (2024) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2024.e00360 · Cited by 5
Sacks, D. B. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4160-6164-9.00026-3 · Cited by 5
Luppa, P. B., Zeller, M., Pieper, M., Kaiser, P., Weiss, N., Vierbaum, L., & Freckmann, G. (2024) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2024.1371426 · Cited by 4
Chakraborty, S., Ghosh, S. S., Das, A., Sawant, P., & Kallner, A. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0644 · Cited by 4
Diagnostik des Gestationsdiabetes: Die Crux liegt bei der Blutentnahme
Kleinwechter, H. J., Heinemann, L., & Freckmann, G. (2015) · Deutsches Ärzteblatt · doi:10.3238/persdia.2015.04.24.06 · Cited by 4
Sample Processing and Specimen Misidentification Issues
Woodworth, A. L., & Pyle, A. L. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-415783-5.00004-9 · Cited by 4
False paraprotein-induced hypoglycemia in the measurement of glucose by the hexokinase method
Bossard, V., Sauvageon, Y., Fraissinet, F., Dreyfus, B., Thuillier, R., & Hauet, T. (2019) · Annales de biologie clinique · doi:10.1684/abc.2019.1465 · Cited by 4
Metadata
- Authors
- Gambino, R., Piscitelli, J., Ackattupathil, T. A., Theriault, J. L., Andrin, R. D., Sanfilippo, M. L., & Etienne, M.
- Affiliations
- Quest Diagnostics (United States) (US)
- Teterboro, NJ
- West Hills, CA, and
- Miramar, FL
- Corresponding author
- Gambino, Raymond
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-05-01
- Volume
- 55
- Issue
- 5
- Pages
- 1019-1021
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2156782964
- Cited by
- 160
- References
- 9
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 8 · 2023: 4 · 2022: 5 · 2021: 9 · 2020: 10 · 2019: 12 · 2018: 13 · 2017: 10 · 2016: 14 · 2015: 11 · 2014: 9 · 2013: 12 · 2012: 16
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Clinical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Keywords
- sodium fluoride, glycolysis inhibition, EDTA, sodium oxalate, blood collection tubes, serum glucose, plasma glucose, blood sample storage, diagnostic thresholds
- MeSH terms
- Blood, Blood Glucose, Blood Preservation, Citrates, Diabetes Mellitus, Glycolysis, Humans, Hydrogen-Ion Concentration, Sodium Fluoride, Specimen Handling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review