25-Hydroxyvitamin D Assays: The Quest For Accuracy
The DOI matches its Crossref record.
Abstract
The recently reported difficulties experienced by Quest Laboratories (1) have once again highlighted concerns about the reliability of 25-hydroxyvitamin D (25-OH-D)1 results, particularly those generated by liquid chromatography–tandem mass spectrometry (LC-MS/MS), the method used by Quest. In the New York Times article of January 8, 2009 (1), a spokesman for Quest admitted that some erroneous results were reported because of problems with calibration and that some of their laboratories “did not always follow proper procedures.” One suspects these shortcomings were influenced by the eye-watering number of 25-OH-D requests received by Quest: 500 000 per month according to John Cannell, quoted in a pathologist’s newsletter (2). This unfortunate episode dramatically emphasizes the need for a rigorous internal quality-assurance system. Such a system must include a role for a quality manager (preferably independent) who should be responsible for the monitoring of internal quality controls and the results of external proficiency-testing schemes. Some of us learned of the Quest problem through John Cannell’s Vitamin D Council newsletter sent out in July 2008 (3). In the same issue, he was promoting, without apparent irony, a commercial kit designed to “accurately” measure 25-OH-D in patient-generated blood spots, a technique that cannot easily be monitored by external proficiency-testing schemes. Those of us who work in clinical laboratories know that “stuff happens.” At some stage in our careers, many of us will probably have to contact clinical colleagues to admit reporting errors of some sort, although almost certainly not on the scale reported in the New York Times . It is to Quest’s credit that they admitted the problem and offered to repeat these analyses free of charge. It is important that the publicity given to Quest’s problems not lead to LC-MS/MS being regarded as an inherently unreliable technique. The introduction of LC-MS/MS represents …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vitamin D for health: a global perspective
Hossein-nezhad, A., & Holick, M. F. (2013) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2013.05.011 · Cited by 1,298
Vitamin D, cognition, and dementia: A systematic review and meta-analysis
Balion, C., Griffith, L. E., Strifler, L., Henderson, M., Patterson, C., Heckman, G., Llewellyn, D. J., & Raina, P. (2012) · Neurology · doi:10.1212/wnl.0b013e31826c197f · Cited by 429
An Update on Vitamin D Metabolism
Saponaro, F., Saba, A., & Zucchi, R. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21186573 · Cited by 308
Vogeser, M., & Seger, C. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.138602 · Cited by 290
Determining Vitamin D Status: A Comparison between Commercially Available Assays
Snellman, G., Melhus, H., Gedeborg, R., Byberg, L., Berglund, L., Wernroth, L., & Michaëlsson, K. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011555 · Cited by 236
“opinion regarding accuracy rather than an unbiased comparator [16,17,18,19,20,21,22].”
BackgroundChalmers, J. D., McHugh, B. J., Docherty, C., Govan, J. R. W., & Hill, A. T. (2013) · Thorax · doi:10.1136/thoraxjnl-2012-202125 · Cited by 164
“lates well with alternative methods such as radioimmunoassay and mass spectrometry,(18) 19 has been used in clinical studies and has been validated using the Vitamin-D External Quality Assessment Scheme methodology.(19)”
Carvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90
Metadata
- Authors
- Carter, G. D.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-07-01
- Volume
- 55
- Issue
- 7
- Pages
- 1300-1302
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1983779516
- Cited by
- 115
- References
- 0
- FWCI
- 11.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.