The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Antibody-Based Protein Multiplex Platforms: Technical and Operational Challenges
Open accessAbstract
Background: The measurement of multiple protein biomarkers may refine risk stratification in clinical settings. This concept has stimulated development of multiplexed immunoassay platforms that provide multiple, parallel protein measurements on the same specimen. Content: We provide an overview of antibody-based multiplexed immunoassay platforms and discuss technical and operational challenges. Multiplexed immunoassays use traditional immunoassay principles in which high-affinity capture ligands are immobilized in parallel arrays in either planar format or on microspheres in suspension. Development of multiplexed immunoassays requires rigorous validation of assay configuration and analytical performance to minimize assay imprecision and inaccuracy. Challenges associated with multiplex configuration include selection and immobilization of capture ligands, calibration, interference between antibodies and proteins and assay diluents, and compatibility of assay limits of quantification. We discuss potential solutions to these challenges. Criteria for assessing analytical multiplex assay performance include the range of linearity, analytical specificity, recovery, and comparison to a quality reference method. Quality control materials are not well developed for multiplexed protein immunoassays, and algorithms for interpreting multiplex quality control data are needed. Summary: Technical and operational challenges have hindered implementation of multiplexed assays in clinical settings. Formal procedures that guide multiplex assay configuration, analytical validation, and quality control are needed before broad application of multiplexed arrays can occur in the in vitro diagnostic market.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein microarrays and proteomics
MacBeath, G. (2002) · Nature Genetics · doi:10.1038/ng1037 · Cited by 846
A multi-rule Shewhart chart for quality control in clinical chemistry.
Westgard, J. O., Barry, P. L., Hunt, M. R., & Groth, T. (1981) · Clinical Chemistry · doi:10.1093/clinchem/27.3.493 · Cited by 831
Multiplexed protein measurement: technologies and applications of protein and antibody arrays
Kingsmore, S. F. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2006 · Cited by 715
(2009) · Humana Press eBooks · doi:10.1007/978-1-59745-240-3 · Cited by 582
Cytometric bead array: a multiplexed assay platform with applications in various areas of biology
Morgan, E., Varro, R., Sepulveda, H., Ember, J. A., Apgar, J., Wilson, J., Lowe, L., Chen, R., Shivraj, L., Agadir, A., et al. (2004) · Clinical Immunology · doi:10.1016/j.clim.2003.11.017 · Cited by 506
The five-parameter logistic: A characterization and comparison with the four-parameter logistic
Gottschalk, P. G., & Dunn, J. R. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.04.035 · Cited by 449
Cooper, M. A., & Singleton, V. T. (2007) · Journal of Molecular Recognition · doi:10.1002/jmr.826 · Cited by 370
Ekins, R. P. (1989) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(89)80079-2 · Cited by 294
Protein microarrays: Promising tools for proteomic research
Templin, M. F., Stoll, D., Schwenk, J. M., Pötz, O., Kramer, S., & Joos, T. O. (2003) · PROTEOMICS · doi:10.1002/pmic.200300600 · Cited by 244
Surface Plasmon Resonance Biosensing
Piliarik, M., Vaisocherová, H., & Homola, J. (2009) · Methods in Molecular Biology · doi:10.1007/978-1-60327-567-5_5 · Cited by 238
Cited by
Uhlén, M., Karlsson, M. J., Hober, A., Svensson, A.-S., Scheffel, J., Kotol, D., Zhong, W., Tebani, A., Strandberg, L., Edfors, F., et al. (2019) · Science Signaling · doi:10.1126/scisignal.aaz0274 · Cited by 495
ELISA in the multiplex era: Potentials and pitfalls
Tighe, P. J., Ryder, R. R., Todd, I., & Fairclough, L. C. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400130 · Cited by 464
Kartikasari, A. E. R., Huertas, C. S., Mitchell, A., & Plebanski, M. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.692142 · Cited by 343
Bioanalytical Chemistry of Cytokines–a Review
Stenken, J. A., & Poschenrieder, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.10.009 · Cited by 302
Leng, Y., Sun, K., Chen, X., & Li, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00382a · Cited by 258
Metadata
- Authors
- Ellington, A. A., Kullo, I. J., Bailey, K. R., & Klee, G. G.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-02-01
- Volume
- 56
- Issue
- 2
- Pages
- 186-193
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2116490593
- Cited by
- 313
- References
- 37
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antibody-Based Protein Multiplex Platforms: Technical and Operational Challenges. https://app.cochat.ai/papers/10.1373/clinchem.2009.127514
- The paper
- Ellington, A. A., Kullo, I. J., Bailey, K. R., & Klee, G. G. (2010). Antibody-Based Protein Multiplex Platforms: Technical and Operational Challenges. Clinical Chemistry. https://doi.org/10.1373/clinchem.2009.127514
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.