The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature: applications of acoustic physics to the analysis of biomolecular interactions
Abstract
The widespread exploitation of biosensors in the analysis of molecular recognition has its origins in the mid‐1990s following the release of commercial systems based on surface plasmon resonance (SPR). More recently, platforms based on piezoelectric acoustic sensors (principally ‘bulk acoustic wave’ (BAW), ‘thickness shear mode’ (TSM) sensors or ‘quartz crystal microbalances’ (QCM)), have been released that are driving the publication of a large number of papers analysing binding specificities, affinities, kinetics and conformational changes associated with a molecular recognition event. This article highlights salient theoretical and practical aspects of the technologies that underpin acoustic analysis, then reviews exemplary papers in key application areas involving small molecular weight ligands, carbohydrates, proteins, nucleic acids, viruses, bacteria, cells and lipidic and polymeric interfaces. Key differentiators between optical and acoustic sensing modalities are also reviewed. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Annexins: From Structure to Function
Gerke, V., & Moss, S. E. (2002) · Physiological Reviews · doi:10.1152/physrev.00030.2001 · Cited by 2,029
Cited by
Critical review on biofilm methods
Azeredo, J., Azevedo, N. F., Briandet, R., Cerca, N., Coenye, T., Costa, A. R., Desvaux, M., Di Bonaventura, G., Hébraud, M., Jaglic, Z., et al. (2017) · Critical Reviews in Microbiology · doi:10.1080/1040841x.2016.1208146 · Cited by 1,045
Biophysics in drug discovery: impact, challenges and opportunities
Renaud, J.-P., Chung, C.-W., Danielson, U. H., Egner, U., Hennig, M., Hubbard, R. E., & Nar, H. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.123 · Cited by 382
Antibody-Based Protein Multiplex Platforms: Technical and Operational Challenges
Ellington, A. A., Kullo, I. J., Bailey, K. R., & Klee, G. G. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.127514 · Cited by 313
Uludag, Y., & Tothill, I. E. (2012) · Analytical Chemistry · doi:10.1021/ac300278p · Cited by 290
Metadata
- Authors
- Cooper, M. A., & Singleton, V. T.
- Venue
- Journal of Molecular Recognition
- Publisher
- Wiley
- Published
- 2007-05
- Volume
- 20
- Issue
- 3
- Pages
- 154-184
- ISSN
- 0952-3499 (ISSN-L)
- 1099-1352
- OpenAlex
- W2143727927
- Cited by
- 370
- References
- 1
- FWCI
- 22.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature: applications of acoustic physics to the analysis of biomolecular interactions. https://app.cochat.ai/papers/10.1002/jmr.826
- The paper
- Cooper, M. A., & Singleton, V. T. (2007). A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature: applications of acoustic physics to the analysis of biomolecular interactions. Journal of Molecular Recognition. https://doi.org/10.1002/jmr.826
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.