Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison of Multiplex Immunoassay Platforms

Open access
Fu, Qin, Zhu, Jie, Van Eyk, Jennifer E·2010·Clinical Chemistry

Abstract

Background: Candidate biomarkers discovered with high-throughput proteomic techniques (along with many biomarkers reported in the literature) must be rigorously validated. The simultaneous quantitative assessment of multiple potential biomarkers across large cohorts presents a major challenge to the field. Multiplex immunoassays represent a promising solution, with the potential to provide quantitative data via parallel analyses. These assays also require substantially less sample and reagents than the traditional ELISA (which is further limited by its ability to measure only a single antigen). We have measured the reproducibility, reliability, robustness, accuracy, and throughput of commercially available multiplex immunoassays to ascertain their suitability for serum biomarker analysis and validation. Methods: Assay platforms MULTI-ARRAY (Meso Scale Discovery), Bio-Plex (Bio-Rad Laboratories), A2 (Beckman Coulter), FAST Quant (Whatman Schleicher & Schuell BioScience), and FlowCytomix (Bender MedSystems) were selected as representative examples of technologies currently used for high-throughput immunoanalysis. All assays were performed according to protocols specified by the manufacturers and with the reagents (diluents, calibrators, blocking reagents, and detecting-antibody mixtures) included with their kits. Results: The quantifiable interval determined for each assay and antigen was based on precision (CV < 25%) and percentage recovery (measured concentration within 20% of the actual concentration). The MULTI-ARRAY and Bio-Plex assays had the best performance with the lowest limits of detection, and the MULTI-ARRAY system had the most linear signal output over the widest concentration range (105 to 106). Cytokine concentrations in unspiked and cytokine-spiked serum samples from healthy individuals were further investigated with the MULTI-ARRAY and Bio-Plex assays. Conclusions: The MULTI-ARRAY and Bio-Plex multiplex immunoassay systems are the most suitable for biomarker analysis or quantification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2009.135087

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 215

Metadata

Authors
Fu, Q., Zhu, J., & Van Eyk, J. E.
Venue
Clinical Chemistry
Published
2010-02-01
Volume
56
Issue
2
Pages
314-318
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2082784086
Cited by
215
References
1
FWCI
5.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Multiplex Immunoassay Platforms. https://app.cochat.ai/papers/10.1373/clinchem.2009.135087
The paper
Fu, Q., Zhu, J., & Van Eyk, J. E. (2010). Comparison of Multiplex Immunoassay Platforms. Clinical Chemistry. https://doi.org/10.1373/clinchem.2009.135087

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.