Comparison of Multiplex Immunoassay Platforms
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Candidate biomarkers discovered with high-throughput proteomic techniques (along with many biomarkers reported in the literature) must be rigorously validated. The simultaneous quantitative assessment of multiple potential biomarkers across large cohorts presents a major challenge to the field. Multiplex immunoassays represent a promising solution, with the potential to provide quantitative data via parallel analyses. These assays also require substantially less sample and reagents than the traditional ELISA (which is further limited by its ability to measure only a single antigen). We have measured the reproducibility, reliability, robustness, accuracy, and throughput of commercially available multiplex immunoassays to ascertain their suitability for serum biomarker analysis and validation. Methods: Assay platforms MULTI-ARRAY (Meso Scale Discovery), Bio-Plex (Bio-Rad Laboratories), A2 (Beckman Coulter), FAST Quant (Whatman Schleicher & Schuell BioScience), and FlowCytomix (Bender MedSystems) were selected as representative examples of technologies currently used for high-throughput immunoanalysis. All assays were performed according to protocols specified by the manufacturers and with the reagents (diluents, calibrators, blocking reagents, and detecting-antibody mixtures) included with their kits. Results: The quantifiable interval determined for each assay and antigen was based on precision (CV < 25%) and percentage recovery (measured concentration within 20% of the actual concentration). The MULTI-ARRAY and Bio-Plex assays had the best performance with the lowest limits of detection, and the MULTI-ARRAY system had the most linear signal output over the widest concentration range (105 to 106). Cytokine concentrations in unspiked and cytokine-spiked serum samples from healthy individuals were further investigated with the MULTI-ARRAY and Bio-Plex assays. Conclusions: The MULTI-ARRAY and Bio-Plex multiplex immunoassay systems are the most suitable for biomarker analysis or quantification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Cited by
ELISA in the multiplex era: Potentials and pitfalls
Tighe, P. J., Ryder, R. R., Todd, I., & Fairclough, L. C. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400130 · Cited by 464
Garay, P. A., Hsiao, E. Y., Patterson, P. H., & McAllister, A. K. (2013) · Brain, Behavior, and Immunity · doi:10.1016/j.bbi.2012.07.008 · Cited by 366
“…Dalgard et al., 2012; Datta and Opp, 2008; Erickson and Banks, 2011; Gandhi et al., 2007; Li et al., 2009; Mukherjee et al., 2011), and the greater sensitivity of the Bioplex system we used has been validated against both ELISA and other multi-plex systems (Fu et al., 2010; Mukherjee et al., 2011).”
Potential-Resolved Multicolor Electrochemiluminescence for Multiplex Immunoassay in a Single Sample
Guo, W., Ding, H., Gu, C., Liu, Y., Jiang, X., Su, B., & Shao, Y. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b09422 · Cited by 364
Bioanalytical Chemistry of Cytokines–a Review
Stenken, J. A., & Poschenrieder, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.10.009 · Cited by 302
Smith, J. G., & Gerszten, R. E. (2017) · Circulation · doi:10.1161/circulationaha.116.025446 · Cited by 206
A family-oriented psychosocial intervention reduces inflammation in low-SES African American youth
Miller, G. E., Brody, G. H., Yu, T., & Chen, E. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1406578111 · Cited by 180
Comparison of Proteomic Assessment Methods in Multiple Cohort Studies
Raffield, L. M., Dang, H., Pratte, K. A., Jacobson, S., Gillenwater, L. A., Ampleford, E., Barjaktarevic, I., Basta, P., Clish, C. B., Comellas, A. P., et al. (2020) · PROTEOMICS · doi:10.1002/pmic.201900278 · Cited by 184
Multisite Comparison of High-Sensitivity Multiplex Cytokine Assays
Breen, E. C., Reynolds, S. M., Cox, C., Jacobson, L. P., Magpantay, L., Mulder, C. B., Dibben, O., Margolick, J. B., Bream, J. H., Sambrano, E., et al. (2011) · Clinical and Vaccine Immunology · doi:10.1128/cvi.05032-11 · Cited by 172
Discrimination, Racial Identity, and Cytokine Levels Among African-American Adolescents
Brody, G. H., Yu, T., Miller, G. E., & Chen, E. (2015) · Journal of Adolescent Health · doi:10.1016/j.jadohealth.2015.01.017 · Cited by 163
“This assay is optimized for assessment of low-grade inflammation in peripheral blood samples from healthy subjects [33].”
Macroporous materials: microfluidic fabrication, functionalization and applications
Wang, B., Prinsen, P., Wang, H., Bai, Z., Wang, H., Luque, R., & Xuan, J. (2017) · Chemical Society Reviews · doi:10.1039/c5cs00065c · Cited by 160
The cytokine temporal profile in rat cortex after controlled cortical impact
Dalgard, C. L., Cole, J. T., Kean, W. S., Lucky, J. J., Sukumar, G., McMullen, D. C., Pollard, H. B., & Watson, W. D. (2012) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2012.00006 · Cited by 121
Prevalence and clinical significance of circulating autoantibodies in idiopathic pulmonary fibrosis
Lee, J. S., Kim, E. J., Lynch, K. L., Elicker, B., Ryerson, C. J., Katsumoto, T. R., Shum, A. K., Wolters, P. J., Cerri, S., Richeldi, L., et al. (2013) · Respiratory Medicine · doi:10.1016/j.rmed.2012.10.018 · Cited by 100
“This system is an FDAcleared fully-automated random-access analyzer, which employs multiplexed fluoromagnetic bead technology to simultaneously perform measurements of multiple autoantibodies in a single sample.(13) The following circulating autoantibodies were tested using the BioPlex system: anticyclic citrullinated…”
MethodThe use of multiplex platforms for absolute and relative protein quantification of clinical material
Christiansson, L., Mustjoki, S., Simonsson, B., Olsson-Strömberg, U., Loskog, A. S. I., & Mangsbo, S. M. (2014) · EuPA Open Proteomics · doi:10.1016/j.euprot.2014.02.002 · Cited by 34
Metadata
- Authors
- Fu, Q., Zhu, J., & Van Eyk, J. E.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-02-01
- Volume
- 56
- Issue
- 2
- Pages
- 314-318
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2082784086
- Cited by
- 215
- References
- 1
- FWCI
- 5.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.