Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Development of a Homogeneous Assay for Measurement of Small Dense LDL Cholesterol

Open access
Ito, Yasuki, Fujimura, Miki, Ohta, Motoko, Hirano, Tsutomu·2011·Clinical Chemistry

Abstract

BACKGROUND: Plasma concentrations of small dense (sd)-LDL are associated with the prevalence of cardiovascular events. However, the special equipment and long assay times required for sd-LDL measurement have hindered its clinical application. Herein, we report development of a simple homogeneous assay for sd-LDL-cholesterol (C) adaptable to autoanalyzers. MATERIALS AND METHODS: We identified suitable surfactants and phospholipases by screening for those selective for the sd-LDL fraction (d 1.044–1.063 kg/L) and for the dissociation of other lipoproteins, including large buoyant LDL (lb-LDL). Principal characteristics of this assay were compared with ultracentrifugal isolation of LDL subfractions and with our previous heparin-magnesium precipitation assay for sd-LDL. We measured sd-LDL-C concentrations in 460 healthy, normolipidemic individuals. RESULTS: We used a polyoxyethylene benzylphenyl ether derivative to dissociate triglyceride-rich lipoproteins and HDLs, whereas sphingomyelinase proved most effective for dissociation of lb-LDL from LDL owing to the higher sphingomyelin content in the lb-LDL subfractions. A polyoxyethylene styrenephenyl ether derivative protected sd-LDL against the dissociative actions of sphingomyelinase and cholesterol oxidase/esterase during an initial incubation step. Next, polyoxyethylene alkyl ether dissociated sd-LDL-C and the cholesterol released from sd-LDL were subsequently measured by using cholesterol oxidase/esterase. The homogeneous method correlated excellently with ultracentrifugation for sd-LDL-C (y = 0.99x – 0.09, R2 = 0.91, n = 60) and exhibited within-run precision CVs <1.1%. The distribution of sd-LDL-C was skewed, and the central 95% of sd-LDL-C concentrations ranged from 0.24 to 0.88 mmol/L (9.4–34.0 mg/dL). CONCLUSIONS: The homogeneous assay allows reproducible measurement of sd-LDL-C within 10 min and appears promising in further investigations of the clinical significance of sd-LDL-C.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2010.149559

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 181

Metadata

Authors
Ito, Y., Fujimura, M., Ohta, M., & Hirano, T.
Venue
Clinical Chemistry
Published
2011-01-01
Volume
57
Issue
1
Pages
57-65
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2145805916
Cited by
181
References
6
FWCI
6.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of a Homogeneous Assay for Measurement of Small Dense LDL Cholesterol. https://app.cochat.ai/papers/10.1373/clinchem.2010.149559
The paper
Ito, Y., Fujimura, M., Ohta, M., & Hirano, T. (2011). Development of a Homogeneous Assay for Measurement of Small Dense LDL Cholesterol. Clinical Chemistry. https://doi.org/10.1373/clinchem.2010.149559

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.