Binding of Hepcidin to Plasma Proteins
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
To the Editor: The hepcidin hormone of 25 amino acid residues is a key regulator of iron homeostasis (1). Hepcidin has been shown to bind in vitro to α2-macroglobulin (α2M)1 and albumin in human plasma (2). It is not known, however, to what extent hepcidin is bound to proteins in vivo. For purposes of clinical interpretation, it is critical to know whether protein-bound or free hepcidin is being quantified. To characterize the binding of hepcidin to plasma proteins, we used gel filtration to fractionate 0.5 mL serum samples from both healthy individuals and patients undergoing hematopoietic stem cell transplantation. We similarly fractionated mixtures of hepcidin and α2M or albumin [1 g/L in 10 mmol/L potassium phosphate buffer, pH 7.4, containing 150 mmol/L NaCl (PBS)]. We used a Superdex™ 200 10/300 GL column (GE Healthcare Biosciences) equilibrated with PBS at a flow rate 0.5 mL/min. The column was calibrated with synthetic hepcidin (Peptide Institute), human albumin, and α2M. We collected 0.5-mL fractions and measured hepcidin in the fractions by HPLC–tandem mass spectrometry (LC-MS/MS) as previously described (3). We observed a single peak, corresponding to free hepcidin, eluting at 21–25 mL. In patient sera containing 36.6 nmol/L (102 μg/L) and 50.4 nmol/L (141 μg/L) endogenous hepcidin, LC-MS/MS analysis revealed very small hepcidin peaks in fractions containing α2M and albumin, respectively (Table 1), but the hepcidin concentration was below the limit of quantification (3). The hepcidin peak area corresponded to 0.7% and 0.9% of the main hepcidin peak, respectively, in the α2M fractions and to 0.9% and 1.3% of the main hepcidin peak, respectively, in the albumin fractions. Thus, approximately 98% of hepcidin was free in samples with increased hepcidin. This result contrasts with the findings of Peslova et al., who calculated that only 11% of hepcidin in the circulation was free (2). The molar ratio of α2M to hepcidin varied from 0.2:1 to 5:1 in their in vitro study, whereas the mean molar ratio of α2M to hepcidin in the serum of healthy individuals is 620:1. The much higher proportion of hepcidin relative to the α2M concentration that these investigators used can explain the difference between our results and those of Peslova et al. Hepcidin was not detectable in the α2M and albumin fractions of healthy individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hepcidin in Human Iron Disorders: Diagnostic Implications
Kroot, J. J., Tjalsma, H., Fleming, R. E., & Swinkels, D. W. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2009.140053 · Cited by 246
Cited by
Lopez, A., Cacoub, P., Macdougall, I. C., & Peyrin-Biroulet, L. (2016) · The Lancet · doi:10.1016/s0140-6736(15)60865-0 · Cited by 1,492
Ganz, T. (2013) · Physiological Reviews · doi:10.1152/physrev.00008.2013 · Cited by 1,122
Hepcidin in the diagnosis of iron disorders
Girelli, D., Nemeth, E., & Swinkels, D. W. (2016) · Blood · doi:10.1182/blood-2015-12-639112 · Cited by 417
Cellular Catabolism of the Iron-Regulatory Peptide Hormone Hepcidin
Preza, G. C., Pinon, R., Ganz, T., & Nemeth, E. (2013) · PLoS ONE · doi:10.1371/journal.pone.0058934 · Cited by 56
“7 kD) and its weak binding to plasma proteins [22], glomerular filtration and proteolysis in proximal tubules [23] is thought to be the major mechanism for hepcidin clearance from blood.”
BackgroundMice with hepcidin‐resistant ferroportin accumulate iron in the retina
Theurl, M., Song, D., Clark, E., Sterling, J., Grieco, S., Altamura, S., Galy, B., Hentze, M., Muckenthaler, M. U., & Dunaief, J. L. (2016) · The FASEB Journal · doi:10.1096/fj.15-276758 · Cited by 36
Unraveling Hepcidin Plasma Protein Binding: Evidence from Peritoneal Equilibration Testing
Diepeveen, L. E., Laarakkers, C. M., Peters, H. P. E., van Herwaarden, A. E., Groenewoud, H., IntHout, J., Wetzels, J. F., van Swelm, R. P. L., & Swinkels, D. W. (2019) · Pharmaceuticals · doi:10.3390/ph12030123 · Cited by 11
“Our finding that hepcidin is not predominantly bound is in line with other literature, in which a merely freely circulating hepcidin was observed using gel chromatography on human serum samples, followed by Liquid Chromatography-Mass Spectrometry (LC-MS/MS) [12].”
BackgroundResult
Metadata
- Authors
- Itkonen, O., Stenman, U.-H., Parkkinen, J., Soliymani, R., Baumann, M., & Hämäläinen, E.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-07-01
- Volume
- 58
- Issue
- 7
- Pages
- 1158-1160
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2113191401
- Cited by
- 29
- References
- 1
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.