Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 242

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High-Resolution Profiling of Fetal DNA Clearance from Maternal Plasma by Massively Parallel Sequencing

Yu, Stephanie CY, Lee, Shara WY, Jiang, Peiyong, Leung, Tak Y, Chan, KC Allen, Chiu, Rossa WK, Lo, YM Dennis·2013·Clinical Chemistry

Abstract

BACKGROUND: With the advent of massively parallel sequencing (MPS), DNA analysis can now be performed in a genomewide manner. Recent studies have demonstrated the high precision of MPS for quantifying fetal DNA in maternal plasma. In addition, paired-end sequencing can be used to determine the size of each sequenced DNA fragment. We applied MPS in a high-resolution investigation of the clearance profile of circulating fetal DNA. METHODS: Using paired-end MPS, we analyzed serial samples of maternal plasma collected from 13 women after cesarean delivery. We also studied the transrenal excretion of circulating fetal DNA in 3 of these individuals by analyzing serial urine samples collected after delivery. RESULTS: The clearance of circulating fetal DNA occurred in 2 phases, with different kinetics. The initial rapid phase had a mean half-life of approximately 1 h, whereas the subsequent slow phase had a mean half-life of approximately 13 h. The final disappearance of circulating fetal DNA occurred at about 1 to 2 days postpartum. Although transrenal excretion was involved in the clearance of circulating fetal DNA, it was not the major route. Furthermore, we observed significant changes in the size profiles of circulating maternal DNA after delivery, but we did not observe such changes in circulating fetal DNA. CONCLUSIONS: MPS of maternal plasma and urinary DNA permits high-resolution study of the clearance profile of circulating fetal DNA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2013.203679

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 242

Metadata

Authors
Yu, S. C., Lee, S. W., Jiang, P., Leung, T. Y., Chan, K. A., Chiu, R. W., & Lo, Y. D.
Venue
Clinical Chemistry
Published
2013-08-01
Volume
59
Issue
8
Pages
1228-1237
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2157454502
Cited by
242
References
1
FWCI
9.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Resolution Profiling of Fetal DNA Clearance from Maternal Plasma by Massively Parallel Sequencing. https://app.cochat.ai/papers/10.1373/clinchem.2013.203679
The paper
Yu, S. C., Lee, S. W., Jiang, P., Leung, T. Y., Chan, K. A., Chiu, R. W., & Lo, Y. D. (2013). High-Resolution Profiling of Fetal DNA Clearance from Maternal Plasma by Massively Parallel Sequencing. Clinical Chemistry. https://doi.org/10.1373/clinchem.2013.203679

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.