Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Circulating Tumor Cell Enumeration with a Combination of Epithelial Cell Adhesion Molecule– and Cell-Surface Vimentin–Based Methods for Monitoring Breast Cancer Therapeutic Response

Open access
Satelli, Arun, Brownlee, Zachary, Mitra, Abhisek, Meng, Qing H, Li, Shulin·2015·Clinical Chemistry

Abstract

BACKGROUND: Detection, isolation, and enumeration of circulating tumor cells (CTCs) from cancer patients has become an important modality in clinical management of patients with breast cancer. Although CellSearch, an epithelial cell adhesion molecule (EpCAM)-based method that is used to isolate epithelial CTCs, has gained prominence, its inability to detect mesenchymal CTCs from breast cancer patients raises concerns regarding its utility in clinical management. METHODS: To address this gap in technology, we recently discovered the utility of cell-surface vimentin (CSV) as a marker for detecting mesenchymal CTCs from sarcoma tumors. In the present study, we tested the sensitivity and specificity of detecting CTCs from blood collected at a random time during therapy from each of 58 patients with metastatic breast cancer by use of 84-1 (a monoclonal antibody against CSV to detect epithelial/mesenchymal-transition CTCs) and CellSearch methods. Additionally, we tested the possibility of improving the sensitivity and specificity of detection by use of additional parameters including nuclear EpCAM localization and epithelial mesenchymal ratios. RESULTS: CTC counts with CSV were significant (P = 0.0053) in differentiating populations responsive and nonresponsive to treatment compared with CTC counts with CellSearch (P = 0.0564). The specificity of CTC detection was found to be highest when the sum of CTC counts from the 2 methods was above a threshold of 8 CTCs/7.5 mL. CONCLUSIONS: The sum of CTC counts from the CellSearch and CSV methods appears to provide new insights for assessment of therapeutic response and thus provides a new approach to personalized medicine in breast cancer patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2014.228122

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 195

Metadata

Authors
Satelli, A., Brownlee, Z., Mitra, A., Meng, Q. H., & Li, S.
Venue
Clinical Chemistry
Published
2015-01-01
Volume
61
Issue
1
Pages
259-266
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2152059640
Cited by
195
References
1
FWCI
5.35
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Circulating Tumor Cell Enumeration with a Combination of Epithelial Cell Adhesion Molecule– and Cell-Surface Vimentin–Based Methods for Monitoring Breast Cancer Therapeutic Response. https://app.cochat.ai/papers/10.1373/clinchem.2014.228122
The paper
Satelli, A., Brownlee, Z., Mitra, A., Meng, Q. H., & Li, S. (2015). Circulating Tumor Cell Enumeration with a Combination of Epithelial Cell Adhesion Molecule– and Cell-Surface Vimentin–Based Methods for Monitoring Breast Cancer Therapeutic Response. Clinical Chemistry. https://doi.org/10.1373/clinchem.2014.228122

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.