Technologies for circulating tumor cell separation from whole blood
Open accessThe DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Abstract
The importance of early cancer diagnosis and improved cancer therapy has been clear for years and has initiated worldwide research towards new possibilities in the care strategy of patients with cancer using technological innovations. One of the key research fields involves the separation and detection of circulating tumor cells (CTC) because of their suggested important role in early cancer diagnosis and prognosis, namely, providing easy access by a liquid biopsy from blood to identify metastatic cells before clinically detectable metastasis occurs and to study the molecular and genetic profile of these metastatic cells. Provided the opportunity to further progress the development of technology for treating cancer, several CTC technologies have been proposed in recent years by various research groups and companies. Despite their potential role in cancer healthcare, CTC methods are currently mainly used for research purposes, and only a few methods have been accepted for clinical application because of the difficulties caused by CTC heterogeneity, CTC separation from the blood, and a lack of thorough clinical validation. Therefore, the standardization and clinical application of various developed CTC technologies remain important subsequent necessary steps. Because of their suggested future clinical benefits, we focus on describing technologies using whole blood samples without any pretreatment and discuss their advantages, use, and significance. Technologies using whole blood samples utilize size-based, immunoaffinity-based, and density-based methods or combinations of these methods as well as positive and negative enrichment during separation. Although current CTC technologies have not been truly implemented yet, they possess high potential as future clinical diagnostic techniques for the individualized therapy of patients with cancer. Thus, a detailed discussion of the clinical suitability of these new advanced technologies could help prepare clinicians for the future and can be a foundation for technologies that would be used to eliminate CTCs in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


![Fig. 3 Different CTC membrane microfilters where a an FMSA contains highly porous and flexible micro spring structures in a single layer [32] and b shows a separable bilayer structure where capture is achieved by a gap between the top and bottom porous membranes with 8-μm-diameter holes arranged hexagonally on the bottom layer and larger holes with a diameter of 40 μm on the top layer [33]](https://figures.cochat.ai/paper-figures/470ae6d8e43a4472bda87f9169a060db/technologies-for-circulating-tumor-cell-separation-from-whole-blood-figure-3.jpg)
![Fig. 4 Microfluidic CTC sorting devices where a Parsortix contains a microscale stepped separation structure (image on the left side) with a cross-sectional gap that gradually decreases the dimension of the fluid path (schematic on the right side) [70, 107] and another microfluidic device and b an MCA contains microcavity arrays with circular- (image on the left side) or rectangular-shaped cavities (image on the right side) [31]](https://figures.cochat.ai/paper-figures/28499fbf2bd8475c8bf2f627439e55e8/technologies-for-circulating-tumor-cell-separation-from-whole-blood-figure-4.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., & Forman, D. (2011) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20107 · Cited by 54,679
Nishimura, R., Osako, T., Nishiyama, Y., Tashima, R., Nakano, M., Fujisue, M., Toyozumi, Y., & Arima, N. (2013) · Oncology · doi:10.1159/000353099 · Cited by 13,166
Involvement of chemokine receptors in breast cancer metastasis
Müller, A., Homey, B., Soto, H., Ge, N., Catron, D., Buchanan, M. E., McClanahan, T., Murphy, E., Yuan, W., Wagner, S. N., et al. (2001) · Nature · doi:10.1038/35065016 · Cited by 5,340
The distribution of secondary growths in cancer of the breast.
Paget, S. (1889) · The Lancet · doi:10.1016/s0140-6736(00)49915-0 · Cited by 5,277
Tumor Metastasis: Molecular Insights and Evolving Paradigms
Valastyan, S., & Weinberg, R. A. (2011) · Cell · doi:10.1016/j.cell.2011.09.024 · Cited by 4,011
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Bray, F., Jemal, A., Grey, N., Ferlay, J., & Forman, D. (2012) · The Lancet Oncology · doi:10.1016/s1470-2045(12)70211-5 · Cited by 2,223
de Bono, J. S., Scher, H. I., Montgomery, R. B., Parker, C., Miller, M. C., Tissing, H., Doyle, G. V., Terstappen, L. W. W. M., Pienta, K. J., & Raghavan, D. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-0872 · Cited by 2,182
High gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681
Research works printed but not linked: 2
- Paget S The distribution of secondary growths in cancer of the breast. 1889 Cancer Metastasis Rev. 1989 8 98 101 2673568
- Peters CE Maestre-Battle D Woodside SM Thomas TE Eaves AC Unbiased enrichment of circulating tumor cells directly from whole blood abstract Proceedings of the 107th annual meeting of the american association for cancer research 2016 New Orleans AACR Abstract nr 511
Cited by
Liquid biopsy: current technology and clinical applications
Nikanjam, M., Kato, S., & Kurzrock, R. (2022) · Journal of Hematology & Oncology · doi:10.1186/s13045-022-01351-y · Cited by 931
Liquid biopsy in cancer: current status, challenges and future prospects
Ma, L., Guo, H., Zhao, Y., Liu, Z., Wang, C., Bu, J., Sun, T., & Wei, J. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-02021-w · Cited by 712
Biomarkers for diagnosis and therapeutic options in hepatocellular carcinoma
Chan, Y.-T., Zhang, C., Wu, J., Lu, P., Xu, L., Yuan, H., Feng, Y., Chen, Z.-S., & Wang, N. (2024) · Molecular Cancer · doi:10.1186/s12943-024-02101-z · Cited by 281
Non-Invasive Biomarkers for Early Detection of Breast Cancer
Li, J., Guan, X., Fan, Z., Ching, L.-M., Li, Y., Wang, X., Cao, W.-M., & Liu, D.-X. (2020) · Cancers · doi:10.3390/cancers12102767 · Cited by 248
Pre-metastatic niche: formation, characteristics and therapeutic implication
Wang, Y., Jia, J., Wang, F., Fang, Y., Yang, Y., Zhou, Q., Yuan, W., Gu, X., Hu, J., & Yang, S. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01937-7 · Cited by 246
“444 Currently, several techniques can be applied to isolate CTCs: immunomagnetic bead sorting, micro-fl uidic sorting and enrichment system, density gradient centrifugal enrichment, etc. 445,446 The CellSearch system is the fi rst FDA-approved method for CTC detection.”
Method
Metadata
- Authors
- Bankó, P., Lee, S. Y., Nagygyörgy, V., Zrínyi, M., Chae, C. H., Cho, D. H., & Telekes, A.
- Affiliations
- Budapest University of Technology and Economics (HU)
- Jeonbuk National University Hospital (KR)
- Semmelweis University (HU)
- Corresponding author
- Telekes, András
- Venue
- Journal of Hematology & Oncology
- Published
- 2019-05-14
- Volume
- 12
- Issue
- 1
- Pages
- 48-48
- ISSN
- 1756-8722 (ISSN-L)
- PMC
- PMC6518774
- OpenAlex
- W2948005896
- Cited by
- 358
- References
- 122
- Citations by year
- 2026: 18 · 2025: 44 · 2024: 56 · 2023: 69 · 2022: 64 · 2021: 50 · 2020: 52 · 2019: 4
- FWCI
- 3.43
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
- Locations
- Journal of Hematology & Oncology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- NNational Research Foundation of Korea (2017R1A2B4012353)
- Research Base Construction Fund Support Program” Funded by Chonbuk National University in 2018. (00000000)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cancer Research › Cancer Genomics and Diagnostics
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Keywords
- circulating tumor cells, liquid biopsy, whole blood, density separation, early cancer detection, metastasis detection, CTC heterogeneity, clinical validation, precision oncology
- MeSH terms
- Liquid Biopsy, Animals, Cell Separation, Humans, Neoplastic Cells, Circulating, Neoplasms, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Technologies for circulating tumor cell separation from whole blood. https://app.cochat.ai/papers/10.1186/s13045-019-0735-4
- The paper
- Bankó, P., Lee, S. Y., Nagygyörgy, V., Zrínyi, M., Chae, C. H., Cho, D. H., & Telekes, A. (2019). Technologies for circulating tumor cell separation from whole blood. Journal of Hematology & Oncology. https://doi.org/10.1186/s13045-019-0735-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.