CoChat

Cannabis Edibles: Blood and Oral Fluid Cannabinoid Pharmacokinetics and Evaluation of Oral Fluid Screening Devices for Predicting Δ9-Tetrahydrocannabinol in Blood and Oral Fluid following Cannabis Brownie Administration

Newmeyer, Matthew N, Swortwood, Madeleine J, Andersson, Maria, Abulseoud, Osama A, Scheidweiler, Karl B, Huestis, Marilyn A · 2017 · Clinical Chemistry
Cited by 57

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Roadside oral fluid (OF) Δ9-tetrahydrocannabinol (THC) detection indicates recent cannabis intake. OF and blood THC pharmacokinetic data are limited and there are no on-site OF screening performance evaluations after controlled edible cannabis. CONTENT: We reviewed OF and blood cannabinoid pharmacokinetics and performance evaluations of the Draeger DrugTest®5000 (DT5000) and Alere™ DDS®2 (DDS2) on-site OF screening devices. We also present data from a controlled oral cannabis administration session. SUMMARY: OF THC maximum concentrations (Cmax) were similar in frequent as compared to occasional smokers, while blood THC Cmax were higher in frequent [mean (range) 17.7 (8.0–36.1) μg/L] smokers compared to occasional [8.2 (3.2–14.3) μg/L] smokers. Minor cannabinoids Δ9-tetrahydrocannabivarin and cannabigerol were never detected in blood, and not in OF by 5 or 8 h, respectively, with 0.3 μg/L cutoffs. Recommended performance (analytical sensitivity, specificity, and efficiency) criteria for screening devices of ≥80% are difficult to meet when maximizing true positive (TP) results with confirmation cutoffs below the screening cutoff. TPs were greatest with OF confirmation cutoffs of THC ≥1 and ≥2 μg/L, but analytical sensitivities were <80% due to false negative tests arising from confirmation cutoffs below the DT5000 and DDS2 screening cutoffs; all criteria were >80% with an OF THC ≥5 μg/L cutoff. Performance criteria also were >80% with a blood THC ≥5 μg/L confirmation cutoff; however, positive OF screening results might not confirm due to the time required to collect blood after a crash or police stop. OF confirmation is recommended for roadside OF screening. ClinicalTrials.gov identification number: NCT02177513

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2016.265371

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 57

Metadata

Authors
Newmeyer, M. N., Swortwood, M. J., Andersson, M., Abulseoud, O. A., Scheidweiler, K. B., & Huestis, M. A.
Venue
Clinical Chemistry
Published
2017-03-01
Volume
63
Issue
3
Pages
647-662
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2587433492
Cited by
57
References
1
FWCI
10.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.