CoChat

Quantified Metrics of Gastric Emptying Delay by Glucagon-Like Peptide-1 Agonists: A Systematic Review and Meta-Analysis With Insights for Periprocedural Management

Open access
Hiramoto, Brent, McCarty, Thomas R., Lodhia, Nayna A., Jenkins, Andrew, Elnaiem, Ahmed, Muftah, Mayssan, Flanagan, Ryan, Chan, Walter W. · 2024 · American Journal of Gastroenterology
Cited by 94

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

INTRODUCTION: Divergent recommendations for periprocedural management of glucagon-like peptide-1 (GLP-1) receptor agonist (GLP-1 RA) medications rely on limited evidence. We performed a systematic review and meta-analysis to provide quantitative measures of gastric emptying relevant to mechanisms of weight loss and to periprocedural management of GLP-1 RA. We hypothesized that the magnitude of gastric emptying delay would be low and of limited clinical significance to procedural sedation risks. METHODS: A protocolized search identified studies on GLP-1 RA that quantified gastric emptying measures. Pooled estimates using random effects were presented as a weighted mean difference with 95% confidence intervals (CIs). Univariate meta-regression was performed to assess the influence of GLP-1 RA type, short-acting vs long-acting mechanism of action, and duration of treatment on gastric emptying. RESULTS: Fifteen studies met the inclusion criteria. Five studies (n = 247) utilized gastric emptying scintigraphy. Mean T 1/2 was 138.4 minutes (95% CI 74.5–202.3) for GLP-1 RA vs 95.0 minutes (95% CI 54.9–135.0) for placebo, with a pooled mean difference of 36.0 minutes (95% CI 17.0–55.0, P < 0.01, I 2 = 79.4%). Ten studies (n = 411) utilized the acetaminophen absorption test, with no significant delay in gastric emptying measured by T max, area under the curve (AUC)4hr, and AUC 5hr with GLP-1 RA (P > 0.05). On meta-regression, the type of GLP-1 RA, mechanism of action, and treatment duration did not impact gastric emptying (P > 0.05). DISCUSSION: While a gastric emptying delay of ∼36 minutes is quantifiable on GLP-1 RA medications, it is of limited magnitude relative to standard periprocedural fasting periods. There were no substantial differences in gastric emptying on modalities reflective of liquid emptying (acetaminophen absorption test), particularly at time points relevant to periprocedural care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.14309/ajg.0000000000002820

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 94

Metadata

Authors
Hiramoto, B., McCarty, T. R., Lodhia, N. A., Jenkins, A., Elnaiem, A., Muftah, M., Flanagan, R., & Chan, W. W.
Venue
American Journal of Gastroenterology
Published
2024-04-18
Volume
119
Issue
6
Pages
1126-1140
ISSN
  • 0002-9270 (ISSN-L)
  • 1572-0241
OpenAlex
W4394919294
Cited by
94
References
38
FWCI
8.84
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantified Metrics of Gastric Emptying Delay by Glucagon-Like Peptide-1 Agonists: A Systematic Review and Meta-Analysis With Insights for Periprocedural Management. https://app.cochat.ai/papers/10.14309/ajg.0000000000002820
The paper
Hiramoto, B., McCarty, T. R., Lodhia, N. A., Jenkins, A., Elnaiem, A., Muftah, M., Flanagan, R., & Chan, W. W. (2024). Quantified Metrics of Gastric Emptying Delay by Glucagon-Like Peptide-1 Agonists: A Systematic Review and Meta-Analysis With Insights for Periprocedural Management. American Journal of Gastroenterology. https://doi.org/10.14309/ajg.0000000000002820

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.