Evaluation of Computer-Aided Detection During Colonoscopy in the Community (AI-SEE): A Multicenter Randomized Clinical Trial
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: There has been increasing interest in artificial intelligence in gastroenterology. To reduce miss rates during colonoscopy, there has been significant exploration in computer-aided detection (CADe) devices. In this study, we evaluate the use of CADe in colonoscopy in community-based, nonacademic practices. METHODS: Between September 28, 2020, and September 24, 2021, a randomized controlled trial (AI-SEE) was performed evaluating the impact of CADe on polyp detection in 4 community-based endoscopy centers in the United States Patients were block-randomized to undergoing colonoscopy with or without CADe (EndoVigilant). Primary outcomes measured were adenomas per colonoscopy and adenomas per extraction (the percentage of polyps removed that are adenomas). Secondary end points included serrated polyps per colonoscopy; nonadenomatous, nonserrated polyps per colonoscopy; adenoma and serrated polyp detection rates; and procedural time. RESULTS: A total of 769 patients were enrolled (387 with CADe), with similar patient demographics between the 2 groups. There was no significant difference in adenomas per colonoscopy in the CADe and non-CADe groups (0.73 vs 0.67, P = 0.496). Although the use of CADe did not improve identification of serrated polyps per colonoscopy (0.08 vs 0.08, P = 0.965), the use of CADe increased identification of nonadenomatous, nonserrated polyps per colonoscopy (0.90 vs 0.51, P < 0.0001), resulting in detection of fewer adenomas per extraction in the CADe group. The adenoma detection rate (35.9 vs 37.2%, P = 0.774) and serrated polyp detection rate (6.5 vs 6.3%, P = 1.000) were similar in the CADe and non-CADe groups. Mean withdrawal time was longer in the CADe group compared with the non-CADe group (11.7 vs 10.7 minutes, P = 0.003). However, when no polyps were identified, there was similar mean withdrawal time (9.1 vs 8.8 minutes, P = 0.288). There were no adverse events. DISCUSSION: The use of CADe did not result in a statistically significant difference in the number of adenomas detected. Additional studies are needed to better understand why some endoscopists derive substantial benefits from CADe and others do not. ClinicalTrials.gov number: NCT04555135.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Edwards, B. K., Ward, E., Kohler, B. A., Eheman, C., Zauber, A. G., Anderson, R. N., Jemal, A., Schymura, M. J., Lansdorp‐Vogelaar, I., Seeff, L. C., et al. (2010) · Cancer · doi:10.1002/cncr.24760 · Cited by 2,002
Strategies for Colorectal Cancer Screening
Ladabaum, U., Dominitz, J. A., Kahi, C., & Schoen, R. E. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.06.043 · Cited by 696
Zhao, S., Wang, S., Pan, P., Xia, T., Chang, X., Yang, X., Guo, L., Meng, Q., Yang, F., Qian, W., et al. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.01.260 · Cited by 660 · cited 1×
“In a separate meta-analysis, Zhao et al (6) reviewed more than 15,000 tandem colonoscopies and found that there was an estimated miss rate of 26% for adenomas, 9% for advanced adenomas, and 27% for serrated polyps.”
BackgroundEfficacy of real-time computer-aided detection of colorectal neoplasia in a randomized trial
Repici, A., Badalamenti, M., Maselli, R., Correale, L., Radaelli, F., Rondonotti, E., Ferrara, E., Spadaccini, M., Alkandari, A., Fugazza, A., et al. (2020) · Gastroenterology · doi:10.1053/j.gastro.2020.04.062 · Cited by 646 · cited 4×
“While several studies, including that by Repici et al, have been performed, these studies have been performed primarily in academic settings (14).”
BackgroundResultInfluentialHassan, C., Spadaccini, M., Iannone, A., Maselli, R., Jovani, M., Chandrasekar, V. T., Antonelli, G., Yu, H., Areia, M., Dinis-Ribeiro, M., et al. (2021) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.06.059 · Cited by 529
Gupta, S., Lieberman, D., Anderson, J. C., Burke, C. A., Dominitz, J. A., Kaltenbach, T., Robertson, D. J., Shaukat, A., Syngal, S., & Rex, D. K. (2020) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000000544 · Cited by 343
Kamba, S., Tamai, N., Saitoh, I., Matsui, H., Horiuchi, H., Kobayashi, M., Sakamoto, T., Ego, M., Fukuda, A., Tonouchi, A., et al. (2021) · Journal of Gastroenterology · doi:10.1007/s00535-021-01808-w · Cited by 124 · cited 1×
“This contrasts to the work by Kamba et al (20), in which CADe signi fi cantly decreased the adenoma miss rate (13.8 vs 36.7%, P , 0.0001) and increased ADR (64.5 vs 53.6%, P 5 0.036) compared withthat withoutCADe.”
ResultInfluentialLadabaum, U., Shepard, J., Weng, Y., Desai, M., Singer, S. J., & Mannalithara, A. (2023) · Gastroenterology · doi:10.1053/j.gastro.2022.12.004 · Cited by 100
Cited by
Han, R., Acosta, J. N., Shakeri, Z., Ioannidis, J. P. A., Topol, E. J., & Rajpurkar, P. (2024) · The Lancet Digital Health · doi:10.1016/s2589-7500(24)00047-5 · Cited by 336
Hassan, C., Spadaccini, M., Mori, Y., Foroutan, F., Facciorusso, A., Gkolfakis, P., Tziatzios, G., Triantafyllou, K., Antonelli, G., Khalaf, K., et al. (2023) · Annals of Internal Medicine · doi:10.7326/m22-3678 · Cited by 216
Karsenti, D., Tharsis, G., Perrot, B., Cattan, P., Percie du Sert, A., Venezia, F., Zrihen, E., Gillet, A., Lab, J.-P., Tordjman, G., et al. (2023) · The Lancet Gastroenterology & Hepatology · doi:10.1016/s2468-1253(23)00104-8 · Cited by 62
Wei, M. T., Fay, S., Yung, D., Ladabaum, U., & Kopylov, U. (2024) · Clinical and Translational Gastroenterology · doi:10.14309/ctg.0000000000000671 · Cited by 57
Self-citationEnhancing human-AI collaboration: The case of colonoscopy
Introzzi, L., Zonca, J., Cabitza, F., Cherubini, P., & Reverberi, C. (2024) · Digestive and Liver Disease · doi:10.1016/j.dld.2023.10.018 · Cited by 28
Metadata
- Authors
- Wei, M. T., Shankar, U., Parvin, R., Abbas, S. H., Chaudhary, S., Friedlander, Y., & Friedland, S.
- Venue
- American Journal of Gastroenterology
- Published
- 2023-03-09
- Volume
- 118
- Issue
- 10
- Pages
- 1841-1847
- ISSN
- 0002-9270 (ISSN-L)
- 1572-0241
- OpenAlex
- W4323652413
- Cited by
- 80
- References
- 8
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Computer-Aided Detection During Colonoscopy in the Community (AI-SEE): A Multicenter Randomized Clinical Trial. https://app.cochat.ai/papers/10.14309/ajg.0000000000002239
- The paper
- Wei, M. T., Shankar, U., Parvin, R., Abbas, S. H., Chaudhary, S., Friedlander, Y., & Friedland, S. (2023). Evaluation of Computer-Aided Detection During Colonoscopy in the Community (AI-SEE): A Multicenter Randomized Clinical Trial. American Journal of Gastroenterology. https://doi.org/10.14309/ajg.0000000000002239
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.