Sleep staging from Heart Rate Variability: time-varying spectral features and Hidden Markov Models
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
An alternative DSS which models the behaviour of the Heart Rate Variability (HRV) signal linked to stable (NREM) and instable (REM) cerebral waves during sleep and a probabilistic model of the sleep stages transitions for decision was developed. Time-Varying Autoregressive Models (TVAMs) were used as feature extractor while Hidden Markov Models (HMM) was used as time series classifier. 24 full polysomnography recordings from healthy sleepers were used for the analysis and those were separated in two sets of 12 each: training and test set. The classification performance for the test set was specificity = 0.851, accuracy = 0.793 and sensitivity = 0.702.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sympathetic neural mechanisms in obstructive sleep apnea.
Somers, V. K., Dyken, M. E., Clary, M. P., & Abboud, F. M. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118235 · Cited by 2,527
Sympathetic-Nerve Activity during Sleep in Normal Subjects
Somers, V. K., Dyken, M. E., Mark, A. L., & Abboud, F. M. (1993) · New England Journal of Medicine · doi:10.1056/nejm199302043280502 · Cited by 1,574 · cited 3×
“, 1995), central apnoea (Somers et al., 1993), and periodic leg movements (Sforza et al.”
Background
Cited by
Emotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461
“There is a large literature on extracting such features from both audiovisual and physiological measurements [44, 43, 29].”
BackgroundSleep Staging Based on Signals Acquired Through Bed Sensor
Kortelainen, J. M., Mendez, M. O., Bianchi, A. M., Matteucci, M., & Cerutti, S. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2044797 · Cited by 201
Self-citationSleep stage classification from heart-rate variability using long short-term memory neural networks
Radha, M., Fonseca, P., Moreau, A., Ross, M., Cerny, A., Anderer, P., Long, X., & Aarts, R. M. (2019) · Scientific Reports · doi:10.1038/s41598-019-49703-y · Cited by 186
A review of automated sleep stage scoring based on physiological signals for the new millennia
Faust, O., Razaghi, H., Barika, R., Ciaccio, E. J., & Acharya, U. R. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.04.032 · Cited by 170
“, 2010 [87] 24 subjects HR statistics Spectral power.”
BackgroundSleep stages classification based on heart rate variability and random forest
Xiao, M., Yan, H., Song, J., Yang, Y., & Yang, X. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.06.001 · Cited by 165
Metadata
- Authors
- Mendez, M. O., Matteucci, M., Castronovo, V., Strambi, L. F., Cerutti, S., & Bianchi, A. M.
- Venue
- International Journal of Biomedical Engineering and Technology
- Publisher
- Inderscience Publishers
- Published
- 2010
- Volume
- 3
- Issue
- 3/4
- Pages
- 246
- ISSN
- 1752-6418 (ISSN-L)
- 1752-6426
- OpenAlex
- W2082749222
- Cited by
- 102
- References
- 2
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.