Sleep Staging Based on Signals Acquired Through Bed Sensor
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We describe a system for the evaluation of the sleep macrostructure on the basis of Emfit sensor foils placed into bed mattress and of advanced signal processing. The signals on which the analysis is based are heart-beat interval (HBI) and movement activity obtained from the bed sensor, the relevant features and parameters obtained through a time-variant autoregressive model (TVAM) used as feature extractor, and the classification obtained through a hidden Markov model (HMM). Parameters coming from the joint probability of the HBI features were used as input to a HMM, while movement features are used for wake period detection. A total of 18 recordings from healthy subjects, including also reference polysomnography, were used for the validation of the system. When compared to wake-nonrapid-eye-movement (NREM)-REM classification provided by experts, the described system achieved a total accuracy of 79+/-9% and a kappa index of 0.43+/-0.17 with only two HBI features and one movement parameter, and a total accuracy of 79+/-10% and a kappa index of 0.44+/-0.19 with three HBI features and one movement parameter. These results suggest that the combination of HBI and movement features could be a suitable alternative for sleep staging with the advantage of low cost and simplicity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A tutorial on hidden Markov models and selected applications in speech recognition
Rabiner, L. R. (1989) · Proceedings of the IEEE · doi:10.1109/5.18626 · Cited by 22,743 · cited 1×
“One of the most suitable is the HMM, which uses the pattern temporality of a time series to define the most probable state based on the history of observations [24], [25].”
MethodHeart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Epidemiology of Obstructive Sleep Apnea: A Population Health Perspective
Young, T., Peppard, P. E., & Gottlieb, D. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2109080 · Cited by 4,244
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
A Wearable Health Care System Based on Knitted Integrated Sensors
Paradiso, R., Loriga, G., & Taccini, N. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854512 · Cited by 729
Nitzan, M., Babchenko, A., Khanokh, B., & Landau, D. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/008 · Cited by 217
Cited by
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
Sleep and the athlete: narrative review and 2021 expert consensus recommendations
Walsh, N. P., Halson, S. L., Sargent, C., Roach, G. D., Nédélec, M., Gupta, L., Leeder, J., Fullagar, H. H., Coutts, A. J., Edwards, B. J., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-102025 · Cited by 571
Digital biomarkers for Alzheimer’s disease: the mobile/wearable devices opportunity
Kourtis, L. C., Regele, O. B., Wright, J. M., & Jones, G. B. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0084-2 · Cited by 476
Sleep Monitoring Based on a Tri-Axial Accelerometer and a Pressure Sensor
Nam, Y., Kim, Y., & Lee, J. (2016) · Sensors · doi:10.3390/s16050750 · Cited by 124
“In [8,26], it has been shown that the heart rate variability (HRV) spectral parameters exhibit significant differences between the different sleep stages and, in particular, they seem to discriminate well between REM and non-REM sleep.”
BackgroundCuppens, K., Karsmakers, P., Van de Vel, A., Bonroy, B., Milosevic, M., Luca, S., Croonenborghs, T., Ceulemans, B., Lagae, L., Van Huffel, S., et al. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2285015 · Cited by 66
Metadata
- Authors
- Kortelainen, J. M., Mendez, M. O., Bianchi, A. M., Matteucci, M., & Cerutti, S.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2010-05
- Volume
- 14
- Issue
- 3
- Pages
- 776-785
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2123418885
- Cited by
- 201
- References
- 7
- FWCI
- 12.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sleep Staging Based on Signals Acquired Through Bed Sensor. https://app.cochat.ai/papers/10.1109/titb.2010.2044797
- The paper
- Kortelainen, J. M., Mendez, M. O., Bianchi, A. M., Matteucci, M., & Cerutti, S. (2010). Sleep Staging Based on Signals Acquired Through Bed Sensor. IEEE Transactions on Information Technology in Biomedicine. https://doi.org/10.1109/titb.2010.2044797
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.