A numerical study on the influence of insulating layer of the hot disk sensor on the thermal conductivity measuring accuracy
Abstract
A numerical study on the influence of the insulation layer of the hot disk sensor on the thermal conductivity measuring accuracy has been conducted. It is found that the influences of the thermal contact resistance and the insulating layer could be excluded in the transient plane source method. Both the kapton5501 and the mica5082 sensor could measure stainless steel and ceramic with a deviation less than 3% while the deviation increases to 54.2% of silica aerogel because of the large heat loss proportion through the mica5082 sensor side. The simulation proved that the heat loss through sensor side and accuracy could be improved by increasing the radius of the sensor.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The hot disk TPS method suffers from substantial systematic errors when applied to low-k thermal insulation materials.
“Despite its well-established reliability for a wide variety of common materials, the hot disk TPS method is also known to suffer from a substantial systematic errors when applied to lowk thermal insulation materials, because of the discrepancies between the idealized model used for data analysis and the actual heat transfer process.”
From Analysis and improvement of the hot disk transient plane source method for low thermal conductivity materials (2020) · cites this paper as [20]
For aerogel samples, TPS measurements using mica-insulated sensors showed a k result 54% higher than polyimide-insulated sensors for the same sample.
“For aerogel samples, there is also a report on the discrepancy in the k result obtained with TPS measurements using different types of sensors insulated with mica and polyimide, where the former type showed a result 54% higher than the later for the same sample. 20”
From Analysis and improvement of the hot disk transient plane source method for low thermal conductivity materials (2020) · cites this paper as [20]
Error in TPS measurement comes from two sources: (1) uncertainty in experimental data and selection of time interval for analysis, and (2) deviation of the original idealized analytical heat transfer model from the practical measurement scenario.
“Error in the TPS measurement 20-31 comes from two sources: (1) uncertainty in the experimental data and the selection of time interval for analysis, and (2) deviation of the original idealized analytical heat transfer model 3, 32 from the practical measurement scenario.”
From Analysis and improvement of the hot disk transient plane source method for low thermal conductivity materials (2020) · cites this paper as [20]
For a thin insulating layer under constant heating power, the average temperature drop between the metal heater and the sample-sensor interface becomes almost constant after a short time, a few multiples of the diffusion time hi^2/αi.
“under constant heating power it is well known 20 that ( ) i T t becomes almost constant after a short time, a few multiples of the diffusion time hi 2 / α i”
From Analysis and improvement of the hot disk transient plane source method for low thermal conductivity materials (2020) · cites this paper as [20]
The bifilar spiral metal heater together with the dielectric insulation layer are usually approximated by several concentric and equally spaced circular rings with constant power in both analytical and numerical prior models.
“The bifilar spiral metal heater together with the dielectric insulation layer are usually approximated by several concentric and equally spaced circular rings with constant power in both analytical 3, 32 and numerical 20, 27-31 prior models.”
From Analysis and improvement of the hot disk transient plane source method for low thermal conductivity materials (2020) · cites this paper as [20]
There is a lack of a clear understanding and quantitatively useful solution to the problem of relating the measurement error for thermal insulation materials to the sensor parameters in a definitive way.
“Although it was mentioned that the finite thermal mass of the sensor can lead to error in some lowk materials, 17, 20 there is still a lack of a clear understanding and quantitatively useful solution to this problem which relates the measurement error for TI materials to the sensor parameters in a definitive way.”
From Analysis and improvement of the hot disk transient plane source method for low thermal conductivity materials (2020) · cites this paper as [20]
Several publications investigated the accuracy and performance of commercial TPS devices based on numerical simulations to study the effect of sensors on TPS measurement for bulk or thin film and the error due to thermal radiation in semitransparent sample.
“In the latter aspect, several publications investigated the accuracy and performance of commercial TPS devices based on numerical simulations to study the effect of the sensors on the TPS measurement for bulk or thin film 20, 27-31 and the error due to thermal radiation in semitransparent sample. 17, 33”
From Analysis and improvement of the hot disk transient plane source method for low thermal conductivity materials (2020) · cites this paper as [20]
Detailed information about the specific fitting and optimization procedure is rarely given in the literature, being typically either described simply as a least square method or not clearly mentioned.
“Detailed information about the specific fitting and optimization procedure is rarely given in the literature, being typically either described simply as a least square method (often without specifying the fitting parameters) 20, 27, 28 or not clearly mentioned. 29”
From Analysis and improvement of the hot disk transient plane source method for low thermal conductivity materials (2020) · cites this paper as [20]
Cited by
Sorted by citations
Zheng, Q., Kaur, S., Dames, C., & Prasher, R. S. (2020) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2020.119331 · Cited by 162 · see citing works
“Zhang et al. attributes the error in the hot disk TPS only to the heat loss to the outer vertical side of the sensor based on numerical simulation using isothermal boundary condition.20 Coquard et al. considered the effect of the sensor thermal mass relative to the sample without in-depth discussion of how these facto…”
MethodResultInfluentialTheoretical accuracy of anisotropic thermal conductivity determined by transient plane source method
Zhang, H., Li, Y.-M., & Tao, W.-Q. (2017) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.01.025 · Cited by 69 · see citing works
Self-citationAn improved platinum probe used for transient plane source method at cryogenic temperatures
Zhao, P., & Wang, Q. (2025) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2025.126207 · Cited by 1 · see citing works
- Authors
- Zhang, H., Jin, Y., Gu, W., Li, Z. Y., & Tao, W. Q.
- Affiliations
- Xi'an Jiaotong University (CN)
- Venue
- Progress in Computational Fluid Dynamics, An International Journal
- Publisher
- Inderscience Publishers
- Published
- 2013
- Volume
- 13
- Issue
- 3/4
- Pages
- 191
- ISSN
- 1468-4349 (ISSN-L)
- 1741-5233
- OpenAlex
- W2136936777
- Cited by
- 50
- References
- 0
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 7 · 2023: 6 · 2022: 3 · 2021: 5 · 2020: 5 · 2019: 2 · 2018: 3 · 2017: 6 · 2016: 2 · 2015: 3 · 2014: 1
- FWCI
- 0.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Progress in Computational Fluid Dynamics An International Journal (publishedVersion)
- Funders
- National Natural Science Foundation of China
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
- Physical Sciences › Engineering › Computational Mechanics › Heat Transfer and Numerical Methods
- Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
- Keywords
- insulating layer, thermal conductivity measurement, measurement accuracy, transient plane source method, thermal contact resistance, heat loss, Kapton, silica aerogel, stainless steel, ceramics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review