The aim of this study was to determine the diagnostic efficacy of free metanephrines in plasma samples drawn in the seated position compared with 24-h urinary metanephrines in detecting pheochromocytomas in Asian patients. This prospective study was conducted at Samsung Medical Center between May 2010 and July 2011. The study contained 245 subjects, including 28 patients with histologically-proven pheochromocytoma, 44 with histologically-proven non-pheochromocytoma, 112 controls suspected of having tumors but with negative investigations during two or more years of follow-up, and 45 healthy normotensive volunteers. Plasma-free metanephrines were measured by LC-MS/MS. The cut-off values with optimal sensitivity and specificity for plasma metanephrine and plasma normetanephrine were 0.33 nmol/L and 0.61 nmol/L, respectively. Both the plasma metanephrines measurement and urinary metanephrines measurement had a sensitivity of 96.4% (p = 1.00). However, the urinary metanephrines measurement was significantly more specific than the plasma metanephrines measurement (94.2% vs. 75.6%; p < 0.001). When we applied cut-off values based on BMI, specificity improved from 75.6% to 87.2%, with a comparable gain in sensitivity. From a diagnostic perspective, measurement of free metanephrines in plasma drawn in the seated position is highly sensitive but insufficiently specific when compared with measurement of 24-h urinary fractionated metanephrines. The specificity may be improved by applying cut-off values based on BMI. We suggest that free metanephrines in plasma drawn from seated position can also be used as an initial screening test to ensure that pheochromocytomas are not missed in Asian patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1507/endocrj.ej14-0384

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 34

Metadata

Authors
Kim, H. J., Lee, J. I., Cho, Y. Y., Lee, S. Y., Kim, J. H., Jung, B. C., Kim, S. W., Chung, J. H., Min, Y.-K., Lee, M.-S., Lee, M.-K., & Kim, J. H.
Venue
Endocrine Journal
Published
2015
Volume
62
Issue
3
Pages
243-250
ISSN
  • 0918-8959 (ISSN-L)
  • 1348-4540
OpenAlex
W2010495879
Cited by
34
References
4
FWCI
2.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic accuracy of plasma free metanephrines in a seated position compared with 24-hour urinary metanephrines in the investigation of pheochromocytoma. https://app.cochat.ai/papers/10.1507/endocrj.ej14-0384
The paper
Kim, H. J., Lee, J. I., Cho, Y. Y., Lee, S. Y., Kim, J. H., Jung, B. C., Kim, S. W., Chung, J. H., Min, Y.-K., Lee, M.-S., Lee, M.-K., & Kim, J. H. (2015). Diagnostic accuracy of plasma free metanephrines in a seated position compared with 24-hour urinary metanephrines in the investigation of pheochromocytoma. Endocrine Journal. https://doi.org/10.1507/endocrj.ej14-0384

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.