Poly-4-hydroxybutyrate (P4HB): a new generation of resorbable medical devices for tissue repair and regeneration
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Poly-4-hydroxybutyrate (P4HB) is a thermoplastic, linear polyester, produced by recombinant fermentation, that can be converted into a wide range of resorbable medical devices. P4HB fibers are exceptionally strong, and can be designed to provide prolonged strength retention in vivo. In 2007, the FDA cleared a monofilament suture made from P4HB for general soft tissue approximation and/or ligation. Subsequently, surgical mesh devices for hernia repair, tendon and ligament repair, and plastic and reconstructive surgery have been introduced for clinical use. This review describes the unique properties of P4HB, its clinical applications, and potential uses that are under development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biopolymers: overview of several properties and consequences on their applications
Van de Velde, K., & Kiekens, P. (2002) · Polymer Testing · doi:10.1016/s0142-9418(01)00107-6 · Cited by 887 · cited 1×
“Comparative data from [7] and [26].”
Engelberg, I., & Kohn, J. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90037-b · Cited by 803 · cited 2×
“Comparative data from [7] and [26].”
Functional Living Trileaflet Heart Valves Grown In Vitro
Hoerstrup, S. P., Sodian, R., Daebritz, S., Wang, J., Bacha, E. A., Martin, D. P., Moran, A. M., Guleserian, K. J., Sperling, J. S., Kaushal, S., et al. (2000) · Circulation · doi:10.1161/01.cir.102.suppl_3.iii-44 · Cited by 595 · cited 1×
“first fabricated trileaflet valve scaffolds from PGA meshes coated with P4HB and, then, seeded these scaffolds with autologous ovine myofibroblasts and endothelial cells [ 11 ].”
BackgroundSelf-citationMedical applications of poly-4-hydroxybutyrate: A strong flexible absorbable biomaterial
Martin, D. P., & Williams, S. F. (2003) · Biochemical Engineering Journal · doi:10.1016/s1369-703x(03)00040-8 · Cited by 510 · cited 1×
“The P4HB homopolymer is currently produced by means of a recombinant Escherichia coli K12 fermentation process [ 16 ].”
MethodSelf-citationTissue engineering auricular reconstruction: in vitro and in vivo studies
Shieh, S.-J., Terada, S., & Vacanti, J. P. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00501-5 · Cited by 194 · cited 1×
“have described the use of P4HB as a scaffold for auricular reconstruction using a cell-seeded tissueengineering approach [ 23 ].”
MethodHoerstrup, S. P., Cummings MRCS, I., Lachat, M., Schoen, F. J., Jenni, R., Leschka, S., Neuenschwander, S., Schmidt, D., Mol, A., Günter, C., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.001172 · Cited by 186 · cited 1×
“have reported the longest study of a P4HB-coated TEVG with follow-up time points of up to 2 years [ 10 ].”
BackgroundWhy δ-Valerolactone Polymerizes and γ-Butyrolactone Does Not
Houk, K. N., Jabbari, A., Hall, H. K., & Alemán, C. (2008) · The Journal of Organic Chemistry · doi:10.1021/jo702567v · Cited by 176
The Extraneural Distribution of γ‐Hydroxybutyrate
Nelson, T., Kaufman, E., Kline, J., & Sokoloff, L. (1981) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1981.tb04689.x · Cited by 144 · cited 1×
“The resulting hydrolytic degradation product, 4HB, is a normal constituent of the mammalian body and is found within a variety of tissues, including brain, heart, kidney, liver, lung, muscle, and brown fat [ 18 ].”
BackgroundDeeken, C. R., & Matthews, B. D. (2013) · ISRN Surgery · doi:10.1155/2013/238067 · Cited by 139
Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications
Martin, D. P., Badhwar, A., Shah, D. V., Rizk, S., Eldridge, S. N., Gagne, D. H., Ganatra, A., Darois, R. E., Williams, S. F., Tai, H.-C., et al. (2013) · Journal of Surgical Research · doi:10.1016/j.jss.2013.03.044 · Cited by 118 · cited 1×
“Recently, however, CR Bard (Murray Hill, NJ, USA) has introduced Phasix mesh, which is an absorbable hernia repair mesh made from knitted P4HB monofilament fibers that has similar handling attributes to existing polypropylene hernia repair meshes [ 5 ].”
BackgroundSelf-citation
Cited by
Roland, L., Grau, M., Matena, J., Teske, M., Gieseke, M., Kampmann, A., Beyerbach, M., Murua Escobar, H., Haferkamp, H., Gellrich, N.-C., et al. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms17010001 · Cited by 862
A review on the thermomechanical properties and biodegradation behaviour of polyesters
Larrañaga, A., & Lizundia, E. (2019) · European Polymer Journal · doi:10.1016/j.eurpolymj.2019.109296 · Cited by 257
Choi, S. Y., Rhie, M. N., Kim, H. T., Joo, J. C., Cho, I. J., Son, J., Jo, S. Y., Sohn, Y. J., Baritugo, K.-A., Pyo, J., et al. (2020) · Metabolic Engineering · doi:10.1016/j.ymben.2019.05.009 · Cited by 207
Hydrolytic Degradation of Polylactic Acid Fibers as a Function of pH and Exposure Time
Vaid, R., Yildirim, E., Pasquinelli, M. A., & King, M. W. (2021) · Molecules · doi:10.3390/molecules26247554 · Cited by 143
Roth, J. S., Anthone, G. J., Selzer, D. J., Poulose, B. K., Pierce, R. A., Bittner, J. G., Hope, W. W., Dunn, R. M., Martindale, R. G., Goldblatt, M. I., et al. (2021) · Annals of Medicine and Surgery · doi:10.1016/j.amsu.2020.12.002 · Cited by 40
Deeken, C. R., Chen, D. C., Lopez-Cano, M., Martin, D. P., & Badhwar, A. (2023) · Frontiers in Surgery · doi:10.3389/fsurg.2023.1157661 · Cited by 32
Self-citation
Metadata
- Authors
- Williams, S. F., Rizk, S., & Martin, D. P.
- Venue
- Biomedizinische Technik/Biomedical Engineering
- Publisher
- Walter de Gruyter GmbH
- Published
- 2013-01-01
- Volume
- 58
- Issue
- 5
- Pages
- 439-52
- ISSN
- 0013-5585 (ISSN-L)
- 1862-278X
- OpenAlex
- W2082696081
- Cited by
- 163
- References
- 20
- FWCI
- 2.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.