CoChat

Citric/citrate buffer: an effective antiglycolytic agent

Open access
del Pino, Isabel García, Constanso, Ignacio, Mourín, Luis Vázquez, Safont, Carmela Barbuzano, Vázquez, Pastora Rodríguez · 2013 · Clinical Chemistry and Laboratory Medicine (CCLM)
Cited by 33

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Background:In order to minimize the influence of glycolysis on diabetes mellitus (DM) diagnostic tests, we have compared the behavior of citric/citrate, fluoride additives and gel-serum with plasma-heparin under careful preanalytical conditions. Subsequently, we compared the effectiveness of both fluoride and citric additives at different pre-centrifugation times. Finally, the influence of citric/citrate collection tube on diagnostic tests results was evaluated. Methods:The first study of 80 voluntary patients assessed the glucose bias of citric/citrate, fluoride additive tubes and gel-serum tubes versus plasma-heparin tubes at several medical decision cut-offs (MDC). The second study performed with 72 volunteers evaluated additives, simulating transport times to the laboratory and centrifugation delay periods. Final evaluation compares the proportion of positive tests in total tests carried out in two different periods. Results:When citric/citrate (n=79) and fluoride tubes (n=60) were compared with plasma-heparin under controlled preanalytical conditions, both met the bias specification for plasma glucose (±1.8%) at seven MDC. On the contrary, serum samples (n=15) did not meet it at five MDC. In the second study, differences in glucose values at distinct pre-centrifugation times were not statistically significant for citric/citrate tubes, but significant for fluoride tubes and also for comparison of fluoride and citric/citrate tubes. Hemolysis in fluoride tubes was higher. Citric/citrate tube implementation in our laboratory caused an increase in positive diagnostic tests that were only statistically significant for gestational diabetes mellitus (GDM) screening. Conclusions:Citric/citrate additive tube is equivalent to plasma-heparin avoiding glycolysis completely and immediately under careful preanalytical conditions even with a 3-h delay in plasma separation. According to used MDC we have not statistically significantly increased the diagnoses of DM cases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm-2012-0735

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 33

Metadata

Authors
del Pino, I. G., Constanso, I., Mourín, L. V., Safont, C. B., & Vázquez, P. R.
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2013-04-02
Volume
51
Issue
10
Pages
1943-1949
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W1995611671
Cited by
33
References
7
FWCI
2.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Citric/citrate buffer: an effective antiglycolytic agent. https://app.cochat.ai/papers/10.1515/cclm-2012-0735
The paper
del Pino, I. G., Constanso, I., Mourín, L. V., Safont, C. B., & Vázquez, P. R. (2013). Citric/citrate buffer: an effective antiglycolytic agent. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2012-0735

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.