European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a new high sensitive cardiac troponin I (hs-cTnI) assay and its 99th percentile upper reference limit (URL). Laboratories from nine European countries evaluated the ARCHITECT Total imprecision of 3.3%–8.9%, 2.0%–3.5% and 1.5%–5.2% was determined for the low, medium and high controls, respectively. The lowest cTnI concentration corresponding to a total CV of 10% was 5.6 ng/L. Common interferences, sample dilution and carryover did not affect the hs-cTnI results. Slight, but statistically significant, differences with sample type were found. Concordance between the investigated hs-cTnI assay and contemporary cTnI assay at 99th percentile cut-off was found to be 95%. TnI was detectable in 75% and 57% of the apparently healthy population using the lower (1.1 ng/L) and upper (1.9 ng/L) limit of the LoD range provided by the ARCHITECT The new ARCHITECT
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analytical Characteristics of High-Sensitivity Cardiac Troponin Assays
Apple, F. S., Collinson, P. O., & for the IFCC Task Force on Clinical Applications of Cardiac Biomarkers (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.165795 · Cited by 861
Cited by
Application of High-Sensitivity Troponin in Suspected Myocardial Infarction
Neumann, J. T., Twerenbold, R., Ojeda, F., Sörensen, N. A., Chapman, A. R., Shah, A. S. V., Anand, A., Boeddinghaus, J., Nestelberger, T., Badertscher, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1803377 · Cited by 346
Self-citationClinical Use of High-Sensitivity Cardiac Troponin in Patients With Suspected Myocardial Infarction
Twerenbold, R., Boeddinghaus, J., Nestelberger, T., Wildi, K., Rubini Gimenez, M., Badertscher, P., & Mueller, C. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.718 · Cited by 255
Chin, C. W. L., Shah, A. S. V., McAllister, D. A., Joanna Cowell, S., Alam, S., Langrish, J. P., Strachan, F. E., Hunter, A. L., Maria Choy, A., Lang, C. C., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu189 · Cited by 233
High-sensitivity assays for troponin in patients with cardiac disease
Westermann, D., Neumann, J. T., Sörensen, N. A., & Blankenberg, S. (2017) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.48 · Cited by 222
0/1-Hour Triage Algorithm for Myocardial Infarction in Patients With Renal Dysfunction
Twerenbold, R., Badertscher, P., Boeddinghaus, J., Nestelberger, T., Wildi, K., Puelacher, C., Sabti, Z., Rubini Gimenez, M., Tschirky, S., du Fay de Lavallaz, J., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.028901 · Cited by 173
Metadata
- Authors
- Krintus, M., Kozinski, M., Boudry, P., Capell, N. E., Köller, U., Lackner, K., Lefèvre, G., Lennartz, L., Lotz, J., Herranz, A. M., Nybo, M., Plebani, M., Sandberg, M. B., Schratzberger, W., Shih, J., Skadberg, Ø., Chargui, A. T., Zaninotto, M., & Sypniewska, G.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2014-01-04
- Volume
- 0
- Issue
- 0
- Pages
- 1657-65
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2020715592
- Cited by
- 153
- References
- 1
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay. https://app.cochat.ai/papers/10.1515/cclm-2014-0107
- The paper
- Krintus, M., Kozinski, M., Boudry, P., Capell, N. E., Köller, U., Lackner, K., Lefèvre, G., Lennartz, L., Lotz, J., Herranz, A. M., Nybo, M., Plebani, M., Sandberg, M. B., Schratzberger, W., Shih, J., Skadberg, Ø., Chargui, A. T., Zaninotto, M., & Sypniewska, G. (2014). European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2014-0107
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.