A checklist for critical appraisal of studies of biological variation
Open accessThe DOI matches its Crossref record; 19 of the 22 references it cites were found in a registry or an index.
Abstract
Data on biological variation are used for many purposes in laboratory medicine but concern exists over the validity of the data reported in some studies. A critical appraisal checklist has been produced by a working group established by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) to enable standardised assessment of existing and future publications of biological variation data. The checklist identifies key elements to be reported in studies to enable safe accurate and effective transport of biological variation data sets across healthcare systems. The checklist is mapped to the domains of a minimum data set required to enable this process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The EuBIVAS was designed and executed in compliance with EFLM recommendations for BV studies [19, 41].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [41]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This may be as a consequence of a combination of the rigor of the approach (subject selection, tight control of pre-analytical factors etc.), the use of modern examination methodology with higher speci fi city and the critically important application of correct statistical approach to data handling with exclusion of outliers [41, 51].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [41]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“EuBIVAS has delivered generalisable high-quality BV data for a wide range of measurands, using samples collected under optimal conditions, minimizing preexamination sources of variation, using modern examination methodology and statistical analyses compliant with EFLM recommendations [19, 41].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [41]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The protocol of our study followed checklist produced by the EFLM Biological Variation Working Group (WG-BV) (14).”
From Biological variation of thyroid stimulating hormone, free triiodothyronine and free thyroxine in healthy subjects in Turkey (2025) · cites this paper as [14]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Examination of the data revealed that there was no steady state in 25(OH)D concentrations across time, a necessary pre-requisite for the BV estimates derivation [19, 41].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [41]
Experimental — accuracy not yet measured
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987 · cited 1×
“Attempts to make BVD accessible to laboratory medicine specialists have resulted in the delivery of a biological variation data base by Ricós and colleagues which is currently hosted online [14–16].”
BackgroundGeneration and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870 · cited 5×
“Test for outliers should be applied to all levels of data (between replicate analysis, between samples within subject, between subjects) [25] .”
BackgroundInfluentialTowards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Clinical Chemistry · doi:10.1373/49.1.1 · Cited by 862
Biological Variation: From Principles to Practice
Fraser, C. G. (2001) · Cited by 653
Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90151-3 · Cited by 395
Current issues in measurement and reporting of urinary albumin excretion
Miller, W. G., Bruns, D. E., Hortin, G. L., Sandberg, S., Aakre, K. M., McQueen, M. J., Itoh, Y., Lieske, J. C., Seccombe, D. W., Jones, G., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.106567 · Cited by 381
Self-citationSolberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90224-5 · Cited by 222
Within-subject biological variation in disease: collated data and clinical consequences
Ricós, C., Iglesias, N., García-Lario, J.-V., Simón, M., Cava, F., Hernández, A., Perich, C., Minchinela, J., Alvarez, V., Doménech, M.-V., et al. (2007) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/000456307780945633 · Cited by 193 · cited 1×
“Attempts to make BVD accessible to laboratory medicine specialists have resulted in the delivery of a biological variation data base by Ricós and colleagues which is currently hosted online [14–16].”
BackgroundIntroduction: Strategies to set global quality specifications in laboratory medicine
C. G. Fraser, A. K. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185184 · Cited by 172
Petitclerc, C., & Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90150-1 · Cited by 141 · cited 2×
“Until such are available the detailed supporting information could be supplied by a series of publications similar to those developed by the IFCC and applying to reference values [3–8].”
BackgroundMethod
Research works printed but not linked: 24
- Bartlett WA. Biological variation data: the need for appraisal of the evidence base. In: Renz H, Tauber R, editors. Advances in clinical chemistry and laboratory medicine. Berlin/Boston: De Gruyter, 2012.
- Bartlett, 2014, Definition of a minimum data set to accompany indices of biological variation International Federation of Clinical Chemistry Poster Abstract - Istanbul Special, Clin Chem Lab Med, 315
- IFCC, 2014, Nomenclature Properties and Units in collaboration between the International Federation of Clinical Chemistry and and the International Union of Pure and Available from http www ifcc org ifcc scientific division sd committees c npu Accessed November, Laboratory Medicine Applied Chemistry, 16
- 2014, Biological Variation Working Group established by the European Federation of Clinical Chemistry and Laboratory Available from http efcclm eu index php wg biological variation html Accessed November, Medicine, 13
- Carobene A, Braga F, Roraas T, Sandberg S, Bartlett WA. A systematic review of data on biological variation for alanine aminotransferase, aspartate aminotransferase and γ-glutamyl transferase. Clin Chem Lab Med 2013;51:1997-2007. · DOI · Paper page
- Dybkaer, 1987, Approved recommendation on the theory and of reference values Part Presentation of observed values related to reference values, Clin Chem Clin Biochem, 25, 657
- Dybkaer R, Solberg HE. Approved recommendation (1987) on the theory and of reference values. Part 6. Presentation of observed values related to reference values. J Clin Chem Clin Biochem 1987;25:657-62.
- Ricós C, Alvarez V, Cava F, Garcia-Lario JV, Hernandez A, Jimenez CV, et al. Current databases on biological variation: pros, cons and progress. Scand J Clin Lab Invest 1999;59: 491-500.
- LOINC, 2014, observation identifiers names and codes Available from https loinc org Accessed November, Logical, 14
- LOINC, Logical observation identifiers names and codes. Avail- able from: https://loinc.org/ Accessed 14 November, 2014.
- Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwiq LM, et al. Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative. Standards for Reporting of Diagnostic Accuracy. Clin Chem 2003;49:1-6. · DOI · Paper page
- Simundic A, Kackov S, Miler M, Fraser CG, Petersen PH. Terms and symbols used on studies of biological variation: the need for harmonisation. Clin Chem 2015;61:438-9.
- Roraas T, Petersen PH, Sandberg S. Confidence intervals and power calculations for within-subject biological variation: effect of analytical variation, number of replicates, number of samples and number of individuals. Clin Chem 2012;58:1306-13.
- Bartlett WA, Braga F, Carobene A, Coskun A, Prusa R, Fernandez- Calle P, et al. Definition of a minimum data set to accompany indices of biological variation. 2014 International Federation of Clinical Chemistry Poster Abstract -IFCC WorldLab Istanbul 2014. Clin Chem Lab Med 2014;52(Special Supp):S315.
- Perich C, Minchinela J, Ricos C, Fernández-Calle P, Doménech MV, Simón M, et al. Biological variation database: structure and criteria used for generation and update. Clin Chem Lab Med 2015;53:299-305.
- Fraser CG, Harris EK. Generation and application of data on biological variation in clinical chemistry. Crit Rev Clin Lab Sci 1989;27:409-37. · DOI · Paper page
- Miller WG, Bruns DE, Hortin GL, Sandberg S, Aakre KM, McQueen MJ, et al. Current issues in measurement and reporting of urinary albumin excretion. Clin Chem 2009; 55:24-38. · DOI · Paper page
- Braga F, Dolci A, Mosca A, Panteghini M. Biological variation of glycated hemoglobin. Clin Chim Acta 2010;411:1006-10.
- 2014, Biological Variation Working Group established by the European Federation of Clinical Chemistry and Laboratory Available from http efcclm eu index php wg biological variation html Accessed November, Medicine, 13
- Nomenclature, Properties and Units (C-NPU) in collaboration between the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the International Union of Pure and Applied Chemistry (IUPAC). Available from: http://www.ifcc. org/ifcc-scientific-division/sd-committees/c-npu/. Accessed 16 November, 2014.
- Bartlett WA, Braga F, Carobene A, Coskun A, Prusa R, Fernandez- Calle P, et al. Identification of key metadata to enable safe accu- rate and effective transferability of biological variation data. 2014 American Association of Clinical Chemistry Annual Meet- ing AACC, Chicago, Illinois. Available from: https://www.aacc. org/∼/media/files/annual-meeting/2014/abstracts/ factors- affecting-test-results.pdf?la=en Abstract A259. Accessed 1 February, 2015.
- Ricós C, Iglesias N, Garcia-Lario JV, Simon M, Cava F, Hernandez A, et al. Within-subject biological variation in disease: collated data and clinical consequences. Ann Clin Biochem 2007;44:343-52. · DOI · Paper page
- Petersen, 1999, PH Strategies to set global analytical quality specifications in laboratory medicine, Clin Lab Invest, 59
- Bartlett, 2014, Identification of key metadata to enable safe accurate and effective transferability of biological variation data Association of Clinical Chemistry Annual Meeting AACC Chicago Illinois Available from : https www aacc org media files annual meeting, American, 259
Cited by
Practical recommendations for managing hemolyzed samples in clinical chemistry testing
Lippi, G., Cadamuro, J., von Meyer, A., & Simundic, A.-M. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1104 · Cited by 144
“and endorsed by the EFLM Working Group for Biological Variation (WG-BV) [35, 36], as shown in Figure 1A.”
Aarsand, A. K., Røraas, T., Fernandez-Calle, P., Ricos, C., Díaz-Garzón, J., Jonker, N., Perich, C., González-Lao, E., Carobene, A., Minchinela, J., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2017.281808 · Cited by 233
Self-citationCeriotti, F., Fernandez-Calle, P., Klee, G. G., Nordin, G., Sandberg, S., Streichert, T., Vives-Corrons, J.-L., & Panteghini, M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0091 · Cited by 181
Self-citationA practical guide to validation and verification of analytical methods in the clinical laboratory
Pum, J. K. W. (2019) · Advances in clinical chemistry · doi:10.1016/bs.acc.2019.01.006 · Cited by 221
Generation of data on within-subject biological variation in laboratory medicine: An update
Braga, F., & Panteghini, M. (2016) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2016.1150252 · Cited by 111
Self-citation
Metadata
- Authors
- Bartlett, W. A., Braga, F., Carobene, A., Coşkun, A., Prusa, R., Fernandez-Calle, P., Røraas, T., Jonker, N., Sandberg, S., & Variati, O. B. O. T. B.
- Affiliations
- University of Dundee (GB)
- University of Milan (IT)
- Ninewells Hospital (GB)
- Acıbadem University (TR)
- Haraldsplass Diakonale Sykehus (NO)
- Haukeland University Hospital (NO)
- Corresponding author
- Bartlett, William A.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2015-01-01
- Volume
- 53
- Issue
- 6
- Pages
- 879-85
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2000730414
- Cited by
- 151
- References
- 19
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 9 · 2023: 20 · 2022: 13 · 2021: 17 · 2020: 12 · 2019: 20 · 2018: 18 · 2017: 11 · 2016: 11 · 2015: 5
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Acibadem University Open Access Repository (submittedVersion)
- Archivio Istituzionale della Ricerca (Universita Degli Studi Di Milano) (submittedVersion, other-oa)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- biological variation, critical appraisal checklist, reporting quality, Minimum Data Set, clinical pathology, research validity, reference values
- MeSH terms
- Biological Assay, Reference Values, Observer Variation, Databases, Factual, Checklist
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.