Generation of data on within-subject biological variation in laboratory medicine: An update
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
In recent decades, the study of biological variation of laboratory analytes has received increased attention. The reasons for this interest are related to the potential practical applications of such knowledge. Biological variation data allow the derivation of important parameters for the interpretation and use of laboratory tests, such as the index of individuality for the evaluation of the utility of population reference intervals for the test interpretation, the estimate of significant change in a timed series of results of an individual, the number of specimens required to obtain an accurate estimate of the homeostatic set point of the analyte and analytical performance specifications that assays should fulfill for their application in the clinical setting. It is, therefore, essential to experimentally derive biological variation information in an accurate and reliable way. Currently, a dated guideline for the biological variation data production and a more recent checklist to assist in the correct preparation of publications related to biological variation studies are available. Here, we update and integrate, with examples, the available guideline for biological variation data production to help researchers to comply with the recommendations of the checklist for drafting manuscripts on biological variation. Particularly, we focus on the distribution of the data, an essential aspect to be considered for the derivation of biological variation data. Indeed, the difficulty in deriving reliable estimates of biological variation for those analytes, the measured concentrations of which are not normally distributed, is more and more evident.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
An Analysis of Variance Test for Normality (Complete Samples)
Shapiro, S. S., & Wilk, M. B. (1965) · Biometrika · doi:10.2307/2333709 · Cited by 23,469
Diagnosis and classification of diabetes mellitus
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s062 · Cited by 5,491
Robust Tests for the Equality of Variances
Brown, M. B., & Forsythe, A. B. (1974) · Journal of the American Statistical Association · doi:10.1080/01621459.1974.10482955 · Cited by 3,216
Hoelzel, W., Weykamp, C., Jeppsson, J.-O., Miedema, K., Barr, J. R., Goodall, I., Hoshino, T., John, W. G., Kobold, U., Little, R., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.024802 · Cited by 690
Sandberg, S., Fraser, C. G., Horvath, A. R., Jansen, R., Jones, G., Oosterhuis, W., Petersen, P. H., Schimmel, H., Sikaris, K., & Panteghini, M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0067 · Cited by 563
Self-citationCurrent issues in measurement and reporting of urinary albumin excretion
Miller, W. G., Bruns, D. E., Hortin, G. L., Sandberg, S., Aakre, K. M., McQueen, M. J., Itoh, Y., Lieske, J. C., Seccombe, D. W., Jones, G., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.106567 · Cited by 381
Little, R. R., Rohlfing, C. L., & Sacks, D. B. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.148841 · Cited by 365
Fraser, C. G. (2012) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.733 · Cited by 286
Reference intervals: the way forward
Ceriotti, F., Hinzmann, R., & Panteghini, M. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008170 · Cited by 199
Self-citation
Cited by
Ceriotti, F., Fernandez-Calle, P., Klee, G. G., Nordin, G., Sandberg, S., Streichert, T., Vives-Corrons, J.-L., & Panteghini, M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0091 · Cited by 181
Self-citationPre-analytical and analytical aspects affecting clinical reliability of plasma glucose results
Pasqualetti, S., Braga, F., & Panteghini, M. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.03.009 · Cited by 41
“We recently published an updated guideline for the production of high-quality BV data to which readers are referred [42].”
MethodSelf-citationCritical review and meta-analysis of biological variation estimates for tumor markers
Marques-Garcia, F., Boned, B., González-Lao, E., Braga, F., Carobene, A., Coskun, A., Díaz-Garzón, J., Fernández-Calle, P., Perich, M. C., Simon, M., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0725 · Cited by 24
Self-citationInfluence of age, gender and body mass index on late-night salivary cortisol in healthy adults
Coelli, S., Farias, C. B., Soares, A. A., Crescente, G. M., Hirakata, V. N., Souza, L. B., Czepielewski, M. A., Camargo, J. L., & Silveiro, S. P. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-1100 · Cited by 19
BioVar: an online biological variation analysis tool.
Korkmaz, S., Zarasız, G., Göksülük, D., Senes, M., Sönmez, C., & Yucel, D. (2020) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2019-0437 · Cited by 12
Metadata
- Authors
- Braga, F., & Panteghini, M.
- Venue
- Critical Reviews in Clinical Laboratory Sciences
- Publisher
- Informa UK Limited
- Published
- 2016-03-14
- Volume
- 53
- Issue
- 5
- Pages
- 313-325
- ISSN
- 1040-8363 (ISSN-L)
- 1549-781X
- OpenAlex
- W2274101897
- Cited by
- 111
- References
- 17
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Generation of data on within-subject biological variation in laboratory medicine: An update. https://app.cochat.ai/papers/10.3109/10408363.2016.1150252
- The paper
- Braga, F., & Panteghini, M. (2016). Generation of data on within-subject biological variation in laboratory medicine: An update. Critical Reviews in Clinical Laboratory Sciences. https://doi.org/10.3109/10408363.2016.1150252
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.