Criteria for assigning laboratory measurands to models for analytical performance specifications defined in the 1st EFLM Strategic Conference
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
This paper, prepared by the EFLM Task and Finish Group on Allocation of laboratory tests to different models for performance specifications (TFG-DM), is dealing with criteria for allocating measurands to the different models for analytical performance specifications (APS) recognized in the 1st EFLM Strategic Conference Consensus Statement. Model 1, based on the effect of APS on clinical outcome, is the model of choice for measurands that have a central role in the decision-making of a specific disease or clinical situation and where cut-off/decision limits are established for either diagnosing, screening or monitoring. Total cholesterol, glucose, HbA 1c , serum albumin and cardiac troponins represent practical examples. Model 2 is based on components of biological variation and should be applied to measurands that do not have a central role in a specific disease or clinical situation, but where the concentration of the measurand is in a steady state. This is best achieved for measurands under strict homeostatic control in order to preserve their concentrations in the body fluid of interest, but it can also be applied to other measurands that are in a steady state in biological fluids. In this case, it is expected that the “noise” produced by the measurement procedure will not significantly alter the signal provided by the concentration of the measurand. This model especially applies to electrolytes and minerals in blood plasma (sodium, potassium, chloride, bicarbonate, calcium, magnesium, inorganic phosphate) and to creatinine, cystatin C, uric acid and total protein in plasma. Model 3, based on state-of-the-art of the measurement, should be used for all the measurands that cannot be included in models 1 or 2.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The classical experimental approach to estimate BV data is not necessarily the optimal approach for delivery of APS.”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [49]
In the citing paper
“Asreported by Ceriotti et al. [49], there are limitations to the standard approach, including the need to carefully assess the relevance and validity of the BV data, e.g. the presence of ' steady state ' , the appropriateness of time intervals, effect of underlying illness and impact of measurand concentrations.”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [49]
In the citing paper
“According to Ceriotti et al. [49] the BV model for calculating APS is better applied for measurands that are under strict homeostatic control.”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [49]
Citations
Cites
Grundy, S. M., Bilheimer, D. W., Chait, A., Clark, L. T., Denke, M. A., Havel, R. J., Hazzard, W. R., Hulley, S. B., Hunninghake, D. B., Kreisberg, R. A., et al. (1993) · JAMA · doi:10.1001/jama.269.23.3015 · Cited by 27,947
Expert Panel on Detection, E. (2001) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.285.19.2486 · Cited by 26,011
Stone, N. J., Robinson, J. G., Lichtenstein, A. H., Bairey Merz, C. N., Blum, C. B., Eckel, R. H., Goldberg, A. C., Gordon, D., Levy, D., Lloyd-Jones, D. M., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437738.63853.7a · Cited by 7,081
International Staging System for Multiple Myeloma
Greipp, P. R., Miguel, J. S., Durie, B. G. M., Crowley, J. J., Barlogie, B., Bladé, J., Boccadoro, M., Child, J. A., Avet-Loiseau, H., Kyle, R. A., et al. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.04.242 · Cited by 2,974
Jonklaas, J., Bianco, A. C., Bauer, A. J., Burman, K. D., Cappola, A. R., Celi, F. S., Cooper, D. S., Kim, B. W., Peeters, R. P., Rosenthal, M. S., et al. (2014) · Thyroid® · doi:10.1089/thy.2014.0028 · Cited by 1,928
Anemia and Blood Transfusion in Critically Ill Patients
Vincent, J. L. (2002) · JAMA · doi:10.1001/jama.288.12.1499 · Cited by 1,821
Worldwide prevalence of anaemia 1993-2005: WHO global database on anaemia.
de Benoist, B., McLean, E., Egll, I., & Cogswell, M. E. (2008) · Cited by 1,543
Corwin, H. L., Gettinger, A., Pearl, R. G., Fink, M. P., Levy, M. M., Abraham, E., MacIntyre, N. R., Shabot, M. M., Duh, M.-S., & Shapiro, M. J. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000104112.34142.79 · Cited by 1,348
KDOQI Clinical Practice Guideline for Hemodialysis Adequacy: 2015 Update
Daugirdas, J. T., Depner, T. A., Inrig, J., Mehrotra, R., Rocco, M. V., Suri, R. S., Weiner, D. E., Greer, N., Ishani, A., MacDonald, R., et al. (2015) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2015.07.015 · Cited by 1,320
Bahn, R. S., Burch, H. B., Cooper, D. S., Garber, J. R., Greenlee, M. C., Klein, I., Laurberg, P., McDougall, I. R., Montori, V. M., Rivkees, S. A., et al. (2011) · Endocrine Practice · doi:10.4158/ep.17.3.456 · Cited by 1,098
Research works printed but not linked: 1
- Panteghini M. Laboratory evaluation of the pancreas. In: Clarke W, editor. Contemporary practice in clinical chemistry, 2nd ed. Washington DC: AACC Press, 2011:333–41.
Cited by
Items 101–188 of 188
Biological variation of serum cholinesterase catalytic concentrations
Altilia, M., Braga, F., Capoferri, A., & Panteghini, M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0346 · Cited by 7
Self-citationJabor, A., Kubíček, Z., Komrsková, J., Vacková, T., Vymětalík, J., & Franeková, J. (2019) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563219826161 · Cited by 7
Aslan, B., Carobene, A., Jonker, N., Galior, K. D., Boned, B., Marqués-García, F., Ricós, C., Bartlett, W. A., Coşkun, A., Díaz–Garzón, J., et al. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.120032 · Cited by 7
Self-citationPanteghini, M. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1014 · Cited by 6
Self-citationAn Overview of Allowable Total Error in the Clinical Laboratory
Campbell, M. R., & Galior, K. D. (2025) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfaf160 · Cited by 6
Györfi, I., Pál, K., Mănescu, I. B., Oprea, O. R., & Dobreanu, M. (2021) · Revista română de medicină de laborator · doi:10.2478/rrlm-2021-0027 · Cited by 6
Long-term biological variation estimates of 13 hematological parameters in healthy Chinese subjects
Li, C., Peng, M., Wu, J. Z., Du, Z., Lü, H., & Zhou, W. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1141 · Cited by 6
Zhang, C., & Zhang, C. (2022) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.24490 · Cited by 6
Biological variation of serum iron from the European biological variation study (EuBIVAS)
Carobene, A., Aarsand, A. K., Coşkun, A., Díaz–Garzón, J., Locatelli, M., Fernández–Calle, P., Sandberg, S., & Ceriotti, F. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1091 · Cited by 6
Self-citationLiu, H., Ng, C. Y., Liu, Q., Teo, T. L., Loh, T. P., Wong, M. S., Sethi, S. K., Tan, J. G., Heng, P. Y., Saw, S., et al. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-022-04472-y · Cited by 6
Evaluation of blood lead measurements by the 6-year external quality assessment program in China
Zhang, C., Yan, Y., Zeng, J., Liu, J., Dong, N., & Zhang, C. (2023) · Clinica Chimica Acta · doi:10.1016/j.cca.2023.117331 · Cited by 6
van den Besselaar, A. M. H. P., Abdoel, C. F., van Rijn, C. J. J., van der Meer, F. J. M., & Cobbaert, C. M. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-1054 · Cited by 6
Estimation of Measurement Uncertainties in Laboratory Medicine
Гурьевна, Ч. А., Tumilovich, A. A., Stepanov, A. V., Vonsky, M. S., Алексеевна, К. Н., Александровна, А. Н., & Emanuel, V. L. (2023) · Measurement Techniques · doi:10.1007/s11018-023-02117-9 · Cited by 5
IFCC recommendations for internal quality control practice: a missed opportunity
Çubukçu, H. C., Thelen, M., Plebani, M., & Panteghini, M. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0486 · Cited by 5
Self-citationPreanalytical Considerations for Implementation of Microsampling Solutions
Collier, B. B., Miesse, P. K., & Grant, R. P. (2023) · Wiley eBooks · doi:10.1002/9781119615583.ch3 · Cited by 5
A Software Tool for Estimating Uncertainty of Bayesian Posterior Probability for Disease
Chatzimichail, T., & Hatjimihail, A. T. (2024) · Diagnostics · doi:10.3390/diagnostics14040402 · Cited by 5
Chung, H., Song, Y. K., Hong, S. K., Hwang, S.-H., Seo, H. S., Whang, D. H., Nam, M., & Lee, D. H. (2017) · PLoS ONE · doi:10.1371/journal.pone.0189882 · Cited by 5
Pneumatic tube transportation of urine samples
Andersen, E. S., & Brandslund, I. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-1198 · Cited by 5
Pasqualetti, S., Carnevale, A., Dolci, A., & Panteghini, M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-1249 · Cited by 5
Self-citationPerformance of HDL-C measurements assessed by a 4-year trueness-based EQA/PT program in China
Zhou, W., Luo, W., Yu, S., Li, H., Wang, D., Zhang, J., Wang, S., Zeng, J., Zhang, C., Zhao, H., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-0658 · Cited by 5
Liu, Q., Lin, Y., Yang, F., Dai, Y., Hang, H., Wang, M., Hu, M., & Yang, F. (2025) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632251350503 · Cited by 4
Yurt, E. F., Alpdemir, M., & Şeneş, M. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0654 · Cited by 4
Application of sigma-based quality control rules for the efficiency of internal quality control
Choi, H., Jeong, I., Cheon, J., Park, C. M., & Lee, S. M. (2025) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2025.e00501 · Cited by 4
Why Metrological Traceability Matters in Medical Laboratory Diagnostics
Lantman, M. V. S., Cobbaert, C., Panteghini, M., van Berkel, M. E. A. T., Smeets, R. L., van Hellemond, J. J., & Thelen, M. (2025) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfaf203 · Cited by 4
Self-citationKaradağ, C., & Demirel, N. (2022) · Laboratory Medicine · doi:10.1093/labmed/lmac077 · Cited by 4
Çalık, G. Y., & Şeneş, M. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1290 · Cited by 4
Tong, Q., Zhang, S., & Zuo, C. (2021) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23814 · Cited by 4
Intra-laboratory variation and its effect on gestational diabetes diagnosis
van den Berg, S. A. A., Thelen, M., & Groenestege, W. M. T. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0979 · Cited by 4
Zhang, J., Luo, W., Zeng, J., Zhang, T., Zhou, W., Zhao, H., Yan, Y., Hu, C., Ma, R., Wang, J., et al. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0274 · Cited by 4
de Medio, E. P., Borrás, Á. M., Alcaraz‐Quiles, J., Castellvií, J. B., Bauzá, F. R., García, Á. S., & Zaragoza, J. M. M. (2020) · Revista de Medicina de Laboratorio · doi:10.20960/revmedlab.00056 · Cited by 4
Pasqualetti, S., Borrillo, F., Rovegno, L., & Panteghini, M. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0850 · Cited by 4
Self-citationManzocchi, S., & van Rooyen, L. J. (2024) · Veterinary Clinical Pathology · doi:10.1111/vcp.13317 · Cited by 3
Trimboli, F., Lucia, F., Angotti, E., Antico, G. C., Giacquinto, L. C., Martucci, M., Mancuso, S., Chirillo, R., Britti, D., Cuda, G., et al. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0145 · Cited by 3
de Jonge, L., Toes‐Zoutendijk, E., Koopmann, B. D. M., Lantman, M. V. S., Vorsselen, B. F.-V., Speijers, C., van Ingen, H., Humer, E., van der Groep, P., Thelen, M., et al. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.119809 · Cited by 3
Setting analytical goals: choosing specification
Kalacheva, O. S., & Plekhanova, O. S. (2018) · Laboratory Service · doi:10.17116/labs20187151-54 · Cited by 3
Hu, G., Sun, Z., Yu, Z., Li, C., Liu, Y., & Peng, M. (2021) · Clinica Chimica Acta · doi:10.1016/j.cca.2021.11.012 · Cited by 3
Dittadi, R., Fabricio, A. S. C., & Gion, M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0047 · Cited by 3
Biological variation of serum cholinesterase activity in healthy subjects
Akbulut, E. D., & Ercan, M. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0240 · Cited by 2
Wang, R., Wang, J., Wu, W., & Wang, D. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1126 · Cited by 2
Fernández–Calle, P., Díaz–Garzón, J., Bartlett, W. A., Coşkun, A., Carobene, A., Lao, E. G., Marqués-García, F., Sufrate-Vergara, B., Moreno-Parro, I., Galior, K. D., et al. (2026) · Clinical Chemistry · doi:10.1093/clinchem/hvag051 · Cited by 2
Self-citationAnalytical performance specifications based on the state-of-the-art for the newborn screening
Guiñón, L., Soler, A., Molina, Á., Marín, J. L., López, R. M., García‐Villoria, J., Sahuquillo, A., & Alvarez, L. (2020) · Clinica Chimica Acta · doi:10.1016/j.cca.2020.07.006 · Cited by 2
Гурьевна, Ч. А., & Tumilovich, A. A. (2021) · International Scientific Symposium Metrology and Metrology Assurance (MMA) · doi:10.1109/mma52675.2021.9610980 · Cited by 2
Long, Q., Qi, T., Liu, Z., Wang, J., Zhao, H., Zeng, J., Zhang, T., Yan, Y., Zhou, W., Zhang, J., et al. (2022) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2022.2025895 · Cited by 2
Алексеевна, К. Н., Aleksanin, S. S., Гурьевна, Ч. А., & Emanuel, V. L. (2022) · Medical alphabet · doi:10.33667/2078-5631-2022-6-30-34 · Cited by 2
Commutability assessment of reference materials for the enumeration of lymphocyte subsets
Li, C., Peng, M., Xu, D., Lü, H., Zhou, W., Liu, Y., Liu, X., & Chen, W. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0915 · Cited by 2
Park, H., & Ko, Y. (2021) · Annals of Laboratory Medicine · doi:10.3343/alm.2021.41.5.447 · Cited by 2
Mutie, C. K., Gatwiri, S., & Warutere, P. (2023) · International Journal of Current Aspects · doi:10.35942/05q2nv90 · Cited by 2
Ceriotti, F., & Panteghini, M. (2023) · Springer eBooks · doi:10.1007/978-3-031-24958-7_7 · Cited by 2
Self-citationYim, J., Rim, J. H., Lim, Y. K., Cho, Y., Park, Y., Kim, S., & Yun, Y.-M. (2023) · Laboratory Medicine Online · doi:10.47429/lmo.2023.13.4.255 · Cited by 1
Ercan, M., Oğuz, E. F., Özcan, M., & Hakan, H. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120545 · Cited by 1
Comparison of radioactive and non-radioactive iothalamate and hippuran to assess kidney function
Mohamed, A. A. A., Gansevoort, R. T., van de Merbel, N. C., van Londen, M., de Borst, M. H., Zijlma, R., Junier, L. A. T., Heerspink, H. J. L., & Stevens, J. (2025) · Clinical Kidney Journal · doi:10.1093/ckj/sfaf293 · Cited by 1
Measurements in laboratory medicine and external quality assessment
Алексеевна, К. Н., Александровна, А. Н., Vonsky, M. S., Гурьевна, Ч. А., & Leonidovich, V. L. (2025) · Izmeritel`naya Tekhnika · doi:10.32446/0368-1025it.2025-5-88-97 · Cited by 1
Reliability maps for longitudinal monitoring: a probabilistic framework
Fagnani, L., Bellio, P., Piccirilli, A., Frascaria, P., Tennina, R., Perilli, M., & Celenza, G. (2026) · Biochimica Clinica · doi:10.23736/s0393-0564.26.00130-5 · Cited by 1
Bitar, M., Samyn, D. R., Helgesson, M., Pettersson-Pablo, P., & Vink, M. (2026) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2026.2679460 · Cited by 1
An improved approach to modelling patient reclassification: HbA 1c as an example
Farrell, C.-J. L., Loh, T. P., Badrick, T., Jones, G. R. D., & Horvath, A. R. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-0259 · Cited by 1
Bell, K., Lord, S. J., Leeflang, M., Horvath, A. R., & Bossuyt, P. M. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-0643 · Cited by 1
Optimizing patient-risk-based internal quality control in clinical chemistry by bias determination
Xiao, G., Liu, Y., Wang, Y., Chen, S. H., Hu, J., & Zhang, S. (2026) · Accreditation and Quality Assurance · doi:10.1007/s00769-026-01720-x · Cited by 1
A roadmap for standardization of serum albumin measurements
Panteghini, M., Auclair, G., Thelen, M., Wu, L., & Wielgosz, R. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-1215 · Cited by 1
Self-citationLantman, M. V. S., de Jong, A., van der Groep, P., Kemper, E. A., de Groot, M. J. M., Vossen, R. C. R. M., Mohrmann, K., ten Kate, J., Frasa, M. A. M., & Thelen, M. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-0319 · Cited by 1
Eneh, N., Abdulrazaq, K., Yusuf, H. D., & Aladegba, O. A. (2019) · Indian Journal of Pharmaceutical and Biological Research · doi:10.30750/ijpbr.7.4.5 · Cited by 1
An example of implementing a new quality requirements algorithm
Busygin, D. A., Arzamasova, O. A., Торшина, И. Г., Кондрашева, Е. А., & Salikhova, A. A. (2019) · Laboratory Service · doi:10.17116/labs20198011101 · Cited by 1
Hakan, H., Akbay, H. İ., Çokluk, E., Huyut, Z., Keskin, S., & Şekeroğlu, M. R. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-0249 · Cited by 1
Quality Management of Laboratory and Diagnostic Studies
Русак, А. А., Алехнович, Л. И., Камышников, В. С., & Шилейко, И. Д. (2022) · Лабораторная диагностика Восточная Европа · doi:10.34883/pi.2022.11.2.011 · Cited by 1
Алексеевна, К. Н., Александровна, А. Н., Гурьевна, Ч. А., & Emanuel, V. L. (2022) · Medical alphabet · doi:10.33667/2078-5631-2022-19-7-11 · Cited by 1
New way to select analytical performance specifications based on the state-of-the-art
Av, M. (2022) · Laboratory Service · doi:10.17116/labs20221104139 · Cited by 1
Ercan, M., Akbulut, E. D., Caniklioğlu, A., Oğuz, E. F., Dülgeroğlu, Y., Avcı, E., & Ercan, Ş. (2025) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2025.04.010 · Cited by 1
Specification of analytical requirements in programmes of external data evaluation
Friedecky, B., & Kratochvíla, J. (2018) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2018.017 · Cited by 1
Chatzimichail, T., & Hatjimihail, A. T. (2020) · Research Square · doi:10.21203/rs.2.20819/v1 · Cited by 1
Analytical quality requirements - problem of determination
Av, M. (2018) · Laboratory Service · doi:10.17116/labs2018713-4
Tanasković, J. V. (2019) · Repozitorij Farmaceutsko-biokemijskog fakulteta (Sveučilišta u Zagrebu)
Proyecto de casa de ejercicios espirituales para las hijas de la caridad en Ávila
González, J. M. P. (1973) · Hogar y arquitectura: revista bimestral de la obra sindical del hogar
Practical recommendations for managing hemolyzed samples in clinical chemistry testing
Lippi, G., Cadamuro, J., Meyer, A., & Šimundić, A.-M. (2023) · Laboratory Service · doi:10.17116/labs20231201140
Seyithanoğlu, M. (2024) · International journal of medical biochemistry/International journal of medical biochemistry : · doi:10.14744/ijmb.2024.81894
Güncel Biyokimya Çalışmaları VIII
Şen, M. B., Atıcı, Y., Ayan, A. M., Deniz, L., Kara, Z. M. Y., Alayunt, N. Ö., Yüksel, A., Odabaşı, M. S., Çakır, M., & Baki, A. M. (2025) · Akademisyen Kitabevi eBooks · doi:10.37609/akya.3443
Estrategias para asegurar la calidad del proceso analítico en el laboratorio clínico
Guiñón, L. (2023) · Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona)
Measurement practices in laboratory medicine and ways to improve external quality assessment
Алексеевна, К. Н., Александровна, А. Н., Vonsky, M. S., Гурьевна, Ч. А., & Emanuel, V. L. (2025) · Measurement Techniques · doi:10.1007/s11018-026-02481-2
Yıldız, Z., Turanlı, D., Alemdar, M., & Orçun, A. (2026) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2026.2623604
Impact of Preanalytical Storage Time and Air Exposure on ROTEM and Coagulation Sample Stability
Storm, B., Grønli, R. H., Pettersen, K., Emblem, Å. E., Joakimsen, I. S., Landsem, A., Mollnes, T. E., & Brekke, O. (2026) · Advances in Hematology · doi:10.1155/ah/5145648
A Software Tool for Estimating Uncertainty of Bayesian Posterior Probability for Disease
Chatzimichail, T., & Hatjimihail, A. T. (2024) · doi:10.5281/zenodo.18604846
Çubukçu, H. C., Hakan, H., Zengi, O., Güngören, M. S., Thelen, M., & Panteghini, M. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-0112
Self-citationZhou, R., Leng, D., Qin, Y., Hei, Y., Shang, X., Zhang, M., Zhou, Y., & Badrick, T. C. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6507304
Lokman, A. A., Alwi, S. S. S., Desa, M. N. M., Amin-Nordin, S., & Yuswan, M. H. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6512412
Yurt, E. F., Alpdemir, M., & Şeneş, M. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-0388
Piggott, C., Thelen, M., Jones, S., Kocna, P., Frasa, M. A. M., van der Hagen, E. A. E., & Benton, S. C. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.121180
Liu, Q., Huang, T., Hu, W., Lin, Y., Mao, L., & Yang, F. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1904985
Güncel Biyokimya Çalışmaları X
Şen, M. B., Erikçi, A., DOĞAN, N., Atıcı, Y., Emre, H. Ö., Yurt, E. F., Alpdemir, M., Alpdemir, M. F., Saka, B., Doğan, T., et al. (2026) · Akademisyen Kitabevi eBooks · doi:10.37609/akya.4266
Elsharkawi, S. M. (2026) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2026.111208
Horvath, A. R., Loh, T. P., Sandberg, S., & Theodorsson, E. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-1472
Self-citation
Metadata
- Authors
- Ceriotti, F., Fernandez-Calle, P., Klee, G. G., Nordin, G., Sandberg, S., Streichert, T., Vives-Corrons, J.-L., & Panteghini, M.
- Affiliations
- IRCCS Ospedale San Raffaele (IT)
- Department of Laboratory Medicine, Hospital Universitario La Paz, Madrid, Spain
- Mayo Clinic (US)
- External Quality Assessment for Clinical Laboratory Investigations in Sweden (Equalis), Uppsala, Sweden
- Haraldsplass Diakonale Sykehus (NO)
- University of Cologne (DE)
- Red Cell Pathology Unit, Hospital Clinic-IDIBAPS, University of Barcelona, Spain
- University of Milan (IT)
- Corresponding author
- Ceriotti, Ferruccio
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2016-08-09
- Volume
- 55
- Issue
- 2
- Pages
- 189-194
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2527798550
- Semantic Scholar
- 94f549d537f17e3cdaacb4ed2795b4a7869c2467
- Cited by
- 181
- References
- 33
- Citations by year
- 2026: 19 · 2025: 17 · 2024: 15 · 2023: 24 · 2022: 22 · 2021: 19 · 2020: 14 · 2019: 14 · 2018: 22 · 2017: 13 · 2016: 1
- FWCI
- 13.40
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Kölner Universitäts PublikationsServer (Universität zu Köln) (publishedVersion)
- INFM-OAR (INFN Catania) (submittedVersion, other-oa)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- analytical performance specifications, biological variation, clinical outcomes, decision limits, homeostatic regulation, electrolytes, creatinine, cystatin C, uric acid, total protein, measurement noise
- MeSH terms
- Blood Chemical Analysis, Cholesterol, Creatinine, Electrolytes, Glucose, Glycated Hemoglobin, Humans, Minerals, Serum Albumin, Troponin, Uric Acid, Clinical Laboratory Techniques, Cystatin C
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.