Criteria for assigning laboratory measurands to models for analytical performance specifications defined in the 1st EFLM Strategic Conference
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
This paper, prepared by the EFLM Task and Finish Group on Allocation of laboratory tests to different models for performance specifications (TFG-DM), is dealing with criteria for allocating measurands to the different models for analytical performance specifications (APS) recognized in the 1st EFLM Strategic Conference Consensus Statement. Model 1, based on the effect of APS on clinical outcome, is the model of choice for measurands that have a central role in the decision-making of a specific disease or clinical situation and where cut-off/decision limits are established for either diagnosing, screening or monitoring. Total cholesterol, glucose, HbA 1c , serum albumin and cardiac troponins represent practical examples. Model 2 is based on components of biological variation and should be applied to measurands that do not have a central role in a specific disease or clinical situation, but where the concentration of the measurand is in a steady state. This is best achieved for measurands under strict homeostatic control in order to preserve their concentrations in the body fluid of interest, but it can also be applied to other measurands that are in a steady state in biological fluids. In this case, it is expected that the “noise” produced by the measurement procedure will not significantly alter the signal provided by the concentration of the measurand. This model especially applies to electrolytes and minerals in blood plasma (sodium, potassium, chloride, bicarbonate, calcium, magnesium, inorganic phosphate) and to creatinine, cystatin C, uric acid and total protein in plasma. Model 3, based on state-of-the-art of the measurement, should be used for all the measurands that cannot be included in models 1 or 2.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The classical experimental approach to estimate BV data is not necessarily the optimal approach for delivery of APS.”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [49]
In the citing paper
“Asreported by Ceriotti et al. [49], there are limitations to the standard approach, including the need to carefully assess the relevance and validity of the BV data, e.g. the presence of ' steady state ' , the appropriateness of time intervals, effect of underlying illness and impact of measurand concentrations.”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [49]
In the citing paper
“According to Ceriotti et al. [49] the BV model for calculating APS is better applied for measurands that are under strict homeostatic control.”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [49]
Citations
Cites
Grundy, S. M., Bilheimer, D. W., Chait, A., Clark, L. T., Denke, M. A., Havel, R. J., Hazzard, W. R., Hulley, S. B., Hunninghake, D. B., Kreisberg, R. A., et al. (1993) · JAMA · doi:10.1001/jama.269.23.3015 · Cited by 27,947
Expert Panel on Detection, E. (2001) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.285.19.2486 · Cited by 26,011
Stone, N. J., Robinson, J. G., Lichtenstein, A. H., Bairey Merz, C. N., Blum, C. B., Eckel, R. H., Goldberg, A. C., Gordon, D., Levy, D., Lloyd-Jones, D. M., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437738.63853.7a · Cited by 7,081
International Staging System for Multiple Myeloma
Greipp, P. R., Miguel, J. S., Durie, B. G. M., Crowley, J. J., Barlogie, B., Bladé, J., Boccadoro, M., Child, J. A., Avet-Loiseau, H., Kyle, R. A., et al. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.04.242 · Cited by 2,974
Jonklaas, J., Bianco, A. C., Bauer, A. J., Burman, K. D., Cappola, A. R., Celi, F. S., Cooper, D. S., Kim, B. W., Peeters, R. P., Rosenthal, M. S., et al. (2014) · Thyroid® · doi:10.1089/thy.2014.0028 · Cited by 1,928
Anemia and Blood Transfusion in Critically Ill Patients
Vincent, J. L. (2002) · JAMA · doi:10.1001/jama.288.12.1499 · Cited by 1,821
Worldwide prevalence of anaemia 1993-2005: WHO global database on anaemia.
de Benoist, B., McLean, E., Egll, I., & Cogswell, M. E. (2008) · Cited by 1,543
Corwin, H. L., Gettinger, A., Pearl, R. G., Fink, M. P., Levy, M. M., Abraham, E., MacIntyre, N. R., Shabot, M. M., Duh, M.-S., & Shapiro, M. J. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000104112.34142.79 · Cited by 1,348
KDOQI Clinical Practice Guideline for Hemodialysis Adequacy: 2015 Update
Daugirdas, J. T., Depner, T. A., Inrig, J., Mehrotra, R., Rocco, M. V., Suri, R. S., Weiner, D. E., Greer, N., Ishani, A., MacDonald, R., et al. (2015) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2015.07.015 · Cited by 1,320
Bahn, R. S., Burch, H. B., Cooper, D. S., Garber, J. R., Greenlee, M. C., Klein, I., Laurberg, P., McDougall, I. R., Montori, V. M., Rivkees, S. A., et al. (2011) · Endocrine Practice · doi:10.4158/ep.17.3.456 · Cited by 1,098
Red Blood Cell Transfusion: A Clinical Practice Guideline From the AABB*
Carson, J. L., Grossman, B. J., Kleinman, S., Tinmouth, A. T., Marques, M. B., Fung, M. K., Holcomb, J. B., Illoh, O., Kaplan, L. J., Katz, L. M., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-1-201206190-00429 · Cited by 1,084
Platelet Transfusion: A Clinical Practice Guideline From the AABB
Kaufman, R. M., Djulbegovic, B., Gernsheimer, T., Kleinman, S., Tinmouth, A. T., Capocelli, K. E., Cipolle, M. D., Cohn, C. S., Fung, M. K., Grossman, B. J., et al. (2015) · Annals of Internal Medicine · doi:10.7326/m14-1589 · Cited by 993
2013 ETA Guideline: Management of Subclinical Hypothyroidism
Pearce, S. H. S., Brabant, G., Duntas, L. H., Monzani, F., Peeters, R. P., Razvi, S., & Wemeau, J.-L. (2013) · European Thyroid Journal · doi:10.1159/000356507 · Cited by 877
Sandberg, S., Fraser, C. G., Horvath, A. R., Jansen, R., Jones, G., Oosterhuis, W., Petersen, P. H., Schimmel, H., Sikaris, K., & Panteghini, M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0067 · Cited by 563
Self-citationProposals for Setting Generally Applicable Quality Goals Solely Based on Biology
Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400103 · Cited by 370
Biondi, B., Bartalena, L., Cooper, D. S., Hegedüs, L., Laurberg, P., & Kahaly, G. J. (2015) · European Thyroid Journal · doi:10.1159/000438750 · Cited by 323
Radiation Therapy and Tamoxifen: Concurrent or Sequential? That Is the Question
Whelan, T., & Levine, M. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.08.955 · Cited by 304
Evaluation and Management of Patients With Isolated Neutropenia
Newburger, P. E., & Dale, D. C. (2013) · Seminars in Hematology · doi:10.1053/j.seminhematol.2013.06.010 · Cited by 247
American Diabetes Association (2016) · Diabetes Care · doi:10.2337/dc16-s008 · Cited by 215
A checklist for critical appraisal of studies of biological variation
Bartlett, W. A., Braga, F., Carobene, A., Coşkun, A., Prusa, R., Fernandez-Calle, P., Røraas, T., Jonker, N., Sandberg, S., & Variati, O. B. O. T. B. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1127 · Cited by 151
Self-citationGeneration of data on within-subject biological variation in laboratory medicine: An update
Braga, F., & Panteghini, M. (2016) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2016.1150252 · Cited by 111
Self-citationVandewalle, A. (2002) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/17.1.1 · Cited by 90
Carobene, A., Braga, F., Roraas, T., Sandberg, S., & Bartlett, W. A. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0096 · Cited by 84
Self-citationReliability of biological variation data available in an online database: need for improvement
Carobene, A. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1133 · Cited by 76
Setting analytical performance specifications based on outcome studies – is it possible?
Horvath, A. R., Bossuyt, P. M. M., Sandberg, S., John, A. S., Monaghan, P. J., Verhagen-Kamerbeek, W. D. J., Lennartz, L., Cobbaert, C. M., Ebert, C., Lord, S. J., et al. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0214 · Cited by 72
Self-citationLanglois, M. R., Descamps, O. S., van der Laarse, A., Weykamp, C., Baum, H., Pulkki, K., von Eckardstein, A., De Bacquer, D., Borén, J., Wiklund, O., et al. (2014) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2013.12.016 · Cited by 72 · cited 1×
“Even if more recent guidelines [4] are discouraging the use of multiple decision thresholds for making clinical decisions, the analytical quality of the measurement of plasma lipids and lipoproteins is crucial for avoiding misclassification of subjects with reference to their cardiovascular risk [5].”
BackgroundDombros, N., Dratwa, M., Feriani, M., Gokal, R., Heimbürger, O., Krediet, R. T., Plum, J., Rodrigues, A. S., Selgas, R., Struijk, D. G., et al. (2005) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfi1116 · Cited by 48
Decision limit for troponin I and assay performance
Sheehan, P., Blennerhassett, J. B., & Vasikaran, S. D. (2002) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563021902161 · Cited by 44
Defining acceptable limits for the metrological traceability of specific measurands
Bais, R., Armbruster, D., Jansen, R., Klee, G. G., Panteghini, M., PASSARELLI, J., & Sikaris, K. A. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0122 · Cited by 43
Self-citationThue, G., Sandberg, S., & Fugelli, P. (1991) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519109091639 · Cited by 35
Self-citationThue, G., & Sandberg, S. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1280 · Cited by 32
Self-citationOptimizing the use of the “state-of-the-art” performance criteria
Haeckel, R., Wosniok, W., & Streichert, T. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1201 · Cited by 16
Self-citationKristoffersen, A., Petersen, P. H., & Sandberg, S. (2012) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2012.011265 · Cited by 16
Self-citation
Research works printed but not linked: 1
- Panteghini M. Laboratory evaluation of the pancreas. In: Clarke W, editor. Contemporary practice in clinical chemistry, 2nd ed. Washington DC: AACC Press, 2011:333–41.
Cited by
Wu, A. H. B., Christenson, R. H., Greene, D. N., Jaffe, A. S., Kavsak, P. A., Ordonez-Llanos, J., & Apple, F. S. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2017.277186 · Cited by 450
Why C-reactive protein is one of the most requested tests in clinical laboratories?
Plebani, M. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0086 · Cited by 197
Practical recommendations for managing hemolyzed samples in clinical chemistry testing
Lippi, G., Cadamuro, J., von Meyer, A., & Simundic, A.-M. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1104 · Cited by 144
Analytical Sigma metrics: A review of Six Sigma implementation tools for medical laboratories
Westgard, S. A., Bayat, H., & Westgard, J. O. (2018) · Biochemia Medica · doi:10.11613/bm.2018.020502 · Cited by 132
The utility of measurement uncertainty in medical laboratories
Braga, F., & Panteghini, M. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1336 · Cited by 121
Self-citation
Metadata
- Authors
- Ceriotti, F., Fernandez-Calle, P., Klee, G. G., Nordin, G., Sandberg, S., Streichert, T., Vives-Corrons, J.-L., & Panteghini, M.
- Affiliations
- IRCCS Ospedale San Raffaele (IT)
- Department of Laboratory Medicine, Hospital Universitario La Paz, Madrid, Spain
- Mayo Clinic (US)
- External Quality Assessment for Clinical Laboratory Investigations in Sweden (Equalis), Uppsala, Sweden
- Haraldsplass Diakonale Sykehus (NO)
- University of Cologne (DE)
- Red Cell Pathology Unit, Hospital Clinic-IDIBAPS, University of Barcelona, Spain
- University of Milan (IT)
- Corresponding author
- Ceriotti, Ferruccio
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2016-08-09
- Volume
- 55
- Issue
- 2
- Pages
- 189-194
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2527798550
- Semantic Scholar
- 94f549d537f17e3cdaacb4ed2795b4a7869c2467
- Cited by
- 181
- References
- 33
- Citations by year
- 2026: 19 · 2025: 17 · 2024: 15 · 2023: 24 · 2022: 22 · 2021: 19 · 2020: 14 · 2019: 14 · 2018: 22 · 2017: 13 · 2016: 1
- FWCI
- 13.40
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Kölner Universitäts PublikationsServer (Universität zu Köln) (publishedVersion)
- INFM-OAR (INFN Catania) (submittedVersion, other-oa)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- analytical performance specifications, biological variation, clinical outcomes, decision limits, homeostatic regulation, electrolytes, creatinine, cystatin C, uric acid, total protein, measurement noise
- MeSH terms
- Blood Chemical Analysis, Cholesterol, Creatinine, Electrolytes, Glucose, Glycated Hemoglobin, Humans, Minerals, Serum Albumin, Troponin, Uric Acid, Clinical Laboratory Techniques, Cystatin C
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.