High-dose biotin therapy leading to false biochemical endocrine profiles: validation of a simple method to overcome biotin interference
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: High-dose biotin therapy is beneficial in progressive multiple sclerosis (MS) and is expected to be adopted by a large number of patients. Biotin therapy leads to analytical interference in many immunoassays that utilize streptavidin-biotin capture techniques, yielding skewed results that can mimic various endocrine disorders. We aimed at exploring this interference, to be able to remove biotin and avoid misleading results. Methods: We measured free triiodothyronine (fT3), free thyroxine (fT4), thyroid-stimulating hormone (TSH), parathyroid homrone (PTH), 25-hydroxyvitamin D (25OHD), follicle-stimulating hormone (FSH), luteinizing hormone (LH), prolactin, C-peptide, cortisol (Roche Diagnostics assays), biotin and its main metabolites (liquid chromatography tandem mass spectrometry) in 23 plasmas from MS patients and healthy volunteers receiving high-dose biotin, and in 39 biotin-unsupplemented patients, before and after a simple procedure (designated N5) designed to remove biotin by means of streptavidin-coated microparticles. We also assayed fT4, TSH and PTH in the 23 high-biotin plasmas using assays not employing streptavidin-biotin binding. Results: The biotin concentration ranged from 31.7 to 1160 µg/L in the 23 high-biotin plasmas samples. After the N5 protocol, the biotin concentration was below the detection limit in all but two samples (8.3 and 27.6 μg/L). Most hormones results were abnormal, but normalized after N5. All results with the alternative methods were normal except two slight PTH elevations. In the 39 biotin-unsupplemented patients, the N5 protocol did not affect the results for any of the hormones, apart from an 8.4% decrease in PTH. Conclusions: We confirm that most streptavidin-biotin hormone immunoassays are affected by high biotin concentrations, leading to a risk of misdiagnosis. Our simple neutralization method efficiently suppresses biotin interference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Barbesino, G. (2016) · Thyroid® · doi:10.1089/thy.2015.0664 · Cited by 105
Cited by
Bilezikian, J. P. (2018) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2018-01225 · Cited by 325
Interferences With Thyroid Function Immunoassays: Clinical Implications and Detection Algorithm
Favresse, J., Burlacu, M.-C., Maiter, D., & Gruson, D. (2018) · Endocrine Reviews · doi:10.1210/er.2018-00119 · Cited by 258
Laboratory Testing in Thyroid Conditions - Pitfalls and Clinical Utility
Soh, S.-B., & Aw, T.-C. (2019) · Annals of Laboratory Medicine · doi:10.3343/alm.2019.39.1.3 · Cited by 136
Subclinical Hyperthyroidism: A Review of the Clinical Literature
Tsai, K., & Leung, A. M. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.02.002 · Cited by 45
Diagnostic procedure in suspected Graves’ disease
Goichot, B., Leenhardt, L., Massart, C., Raverot, V., Tramalloni, J., & Iraqi, H. (2018) · Annales d Endocrinologie · doi:10.1016/j.ando.2018.08.002 · Cited by 32
Metadata
- Authors
- Piketty, M.-L., Prie, D., Sedel, F., Bernard, D., Hercend, C., Chanson, P., & Souberbielle, J.-C.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2017-06-01
- Volume
- 55
- Issue
- 6
- Pages
- 817-825
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2590918357
- Cited by
- 139
- References
- 1
- FWCI
- 14.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-dose biotin therapy leading to false biochemical endocrine profiles: validation of a simple method to overcome biotin interference. https://app.cochat.ai/papers/10.1515/cclm-2016-1183
- The paper
- Piketty, M.-L., Prie, D., Sedel, F., Bernard, D., Hercend, C., Chanson, P., & Souberbielle, J.-C. (2017). High-dose biotin therapy leading to false biochemical endocrine profiles: validation of a simple method to overcome biotin interference. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2016-1183
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.